EUVIMEDEUVIMED entdecken
Crossref

A Novel Design Strategy for Customized Polyetheretherketone Implants in Paranasal Augmentation Through Surgeon-Engineer Collaboration

Qi Jin, Yu He, Binghang Li, Hengyuan Ma, Hao Qu, Danying Wang, XiaoLei Jin, Xiaojun Tang iD

Aesthetic Plastic Surgery · 2026-01 · 50 (2) · 592-603

DOI: 10.1007/s00266-025-05347-0 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Aesthetic Plastic Surgery, online erschienen am 29.10.2025. Verfasst von Qi Jin und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Craniomaxillofacial Surgery, Plastic Surgery Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, 33# Badach…. Hauptthemen laut MEDLINE: Ketones, Prosthesis Design, Polyethylene Glycols, Prostheses and Implants. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 22 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Paranasal concavity, particularly prevalent in East Asian females, contributes to a prematurely aged facial profile. The paranasal augmentation with customized polyetheretherketone (PEEK) implants offers an effective solution for this aesthetic concern. However, conventional design strategies often encounter challenges in bridging the knowledge gap between surgical requirements and engineering implementation, which may result in unsatisfactory aesthetic outcomes. The optimized interdisciplinary approach is required to integrate clinical and engineering expertise. Therefore, the present study aims to introduce a novel design strategy for customized PEEK implants in paranasal augmentation and to investigate clinical outcomes. METHODS: The present study enrolled 36 consecutive female patients with bilateral paranasal concavity. A surgeon-engineer collaboration workflow was established. The placement position, size, thickness, screw channel, and surface morphology of the implant were the key factors for implant design. Perioperative medical data were meticulously collected and analyzed. The outcomes were evaluated by objective quantitative measurements (maximum concavity depth of paranasal region, nasolabial angle, alar base width, nasorostral angle, philtrum length, and nasal columella length), and subjective questionnaire focused on satisfaction and design experience. RESULTS: The mean operative duration was 55.28 ± 10.89 minutes with minimal intraoperative blood loss. The most common complication was transient perioral numbness. The wound nonunion and infection were not observed in all patients at final follow-up. Quantitative analysis demonstrated significant improvements in paranasal region: maximum concavity depth decreased from 5.45 ± 0.68 to 1.64 ± 0.53 mm (right side, p

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

KetonesProsthesis DesignPolyethylene GlycolsProstheses and ImplantsRhinoplastyHumansBenzophenonesFemaleAdultMiddle AgedPolymersEstheticsTreatment OutcomePatient SatisfactionRetrospective StudiesCohort StudiesFollow-Up StudiesYoung Adult

Stichwörter der Autor:innen

Facial aestheticsInterdisciplinary collaborationNasal base concavityParanasal augmentationPolyetheretherketone

Substanzen

polyetheretherketoneBenzophenonesKetonesPolyethylene GlycolsPolymers

Autor:innen und Institutionen

  • Department of Craniomaxillofacial Surgery, Plastic Surgery Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, 33# Badachu Road, Shijingshan District, Beijing, China.
  • Department of Digital Technology Center, Plastic Surgery Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
  • Department of Plastic Surgery, Plastic Surgery Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
  • Department of Scar and Wound Treatment Center, Plastic Surgery Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
  • Department of Craniomaxillofacial Surgery, Plastic Surgery Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, 33# Badachu Road, Shijingshan District, Beijing, China. frog30@126.com.

ORCID-Profile: Xiaojun Tang

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Jin, Q., He, Y., Li, B., Ma, H., Qu, H., Wang, D., Jin, X., & Tang, X. (2026). A Novel Design Strategy for Customized Polyetheretherketone Implants in Paranasal Augmentation Through Surgeon-Engineer Collaboration. Aesthetic Plastic Surgery, 50(2), 592-603. https://doi.org/10.1007/s00266-025-05347-0

Vancouver

Jin Q, He Y, Li B, Ma H, Qu H, Wang D, et al. A Novel Design Strategy for Customized Polyetheretherketone Implants in Paranasal Augmentation Through Surgeon-Engineer Collaboration. Aesthetic Plastic Surgery. 2026;50(2):592-603. doi:10.1007/s00266-025-05347-0

BibTeX
@article{Jin2026,
  author = {Jin, Qi and He, Yu and Li, Binghang and Ma, Hengyuan and Qu, Hao and Wang, Danying and Jin, XiaoLei and Tang, Xiaojun},
  title = {A Novel Design Strategy for Customized Polyetheretherketone Implants in Paranasal Augmentation Through Surgeon-Engineer Collaboration},
  journal = {Aesthetic Plastic Surgery},
  year = {2026},
  volume = {50},
  number = {2},
  pages = {592--603},
  doi = {10.1007/s00266-025-05347-0}
}
Kostenlos starten →