The Safety of Injections in the Infraorbital Region
Aesthetic Plastic Surgery · 2024
DOI: 10.1007/s00266-024-03976-5 ↗Kurz gefasst
Fachartikel in der Zeitschrift Aesthetic Plastic Surgery, 2024. Verfasst von Ling-Cong Zhou und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Plastic and Reconstructive Surgery, Guang Dong Second Provincial People's Hospital, The Affiliated Guangdong Second Provincial General …. Hauptthemen laut MEDLINE: Dermal Fillers, Orbit. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 29 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Infraorbital filler injection is a commonly used minimally invasive cosmetic procedure on the face, which can cause vascular complications. OBJECTIVE: In this study, we aimed to explore the anatomical structure of the infraorbital vasculature and to establish an accurate protocol for infraorbital filler injection. METHODS: The vascular structure of the infraorbital region was evaluated in 84 hemifacial specimens using computed tomography. Four segments (P1-P4) and five sections (C1-C5) were considered. We recorded the number of identified arteries in each slice and at each location and the number of deep arteries. Furthermore, we also measured the infraorbital artery (IOA) distribution. RESULTS: At P1-P4, the lowest number of arteries was detected in segment P4, with a 317/1727 (18.4%) and 65/338 (2.3%) probability of total and deep arterial identification, respectively. The probabilities of encountering an identified artery at the five designated locations (C1-C5) were 277/1727 (16%), 318/1727 (18.4%), 410/1727 (23.7%), 397/1727 (23%), and 325/1727 (18.8%), respectively. The probability of an IOA being identified at C2 was 68/84 (81%). CONCLUSION: We described an effective filler injection technique in the infraorbital region to minimize the associated risks. LEVEL OF EVIDENCE IV: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Plastic and Reconstructive Surgery, Guang Dong Second Provincial People's Hospital, The Affiliated Guangdong Second Provincial General Hospital of Jinan University, 466 Middle Xin Gang Road, Guangzhou, 510…
- Department of Plastic and Cosmetic Surgery, Yueyang Central Hospital, Yueyang, Hunan, China.
ORCID-Profile: Sheng-Kang Luo
Zitieren
APA
Zhou, L. C., Dong, Y. X., Cao, M. B., Li, J. Y., Peng, T., Zhang, S. Y., Zhou, Y. W., Shu, H. N., & Luo, S. K. (2024). The Safety of Injections in the Infraorbital Region. Aesthetic Plastic Surgery. https://doi.org/10.1007/s00266-024-03976-5
Vancouver
Zhou LC, Dong YX, Cao MB, Li JY, Peng T, Zhang SY, et al. The Safety of Injections in the Infraorbital Region. Aesthetic Plastic Surgery. 2024. doi:10.1007/s00266-024-03976-5
BibTeX
@article{Zhou2024,
author = {Zhou, Ling-Cong and Dong, Yun-Xian and Cao, Mi-Bu and Li, Jun-Yu and Peng, Tong and Zhang, Si-Yi and Zhou, Yang-Wu and Shu, Hai-Ning and Luo, Sheng-Kang},
title = {The Safety of Injections in the Infraorbital Region},
journal = {Aesthetic Plastic Surgery},
year = {2024},
doi = {10.1007/s00266-024-03976-5}
}
EUVIMED