EUVIMEDEUVIMED entdecken
Crossref

The effect of three dimensional-printed guides on assisting rotational axis localization of hinged external fixator in the surgery for elbow terrible triad injury

Huizhi Chen, Tianyu Zhao, Hongwei Gao, Pengcheng Ma

International Orthopaedics · 04.11.2026

DOI: 10.1007/s00264-026-07067-9 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Orthopaedics, online erschienen am 04.11.2026. Verfasst von Huizhi Chen und 3 weiteren Autor:innen. Beteiligte Einrichtung: Shandong Public Health Clinical Center, Shandong University, Jinan, China. Die Arbeit nennt 32 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: This study evaluated the effect of 3D-printed guides on rotation-axis localization for hinged external fixation in terrible triad (TT) injury of the elbow. METHODS: We enrolled 55 patients with TT injuries treated with a hinged external fixator between January 2017 and January 2025, divided into a guide group (n = 29) and a freehand group (n = 26) according to the method of rotation-axis localization, with follow-up at six weeks and one year postoperatively. Pin insertion time, number of fluoroscopic exposures, elbow range of motion, functional elbow rate, Mayo Elbow Performance Score (MEPS), type and incidence of complications, and number and causes of reoperations were compared between groups. RESULTS: Compared with the freehand group, the guide group had a shorter mean pin insertion time (300.93 ± 21.97 s vs. 1392.5 ± 218.16 s) and fewer fluoroscopic exposures (2.31 ± 0.54 vs. 17.50 ± 2.93; both P 0.05). At the final follow-up, flexion-extension arc (134.36° ± 18.21° vs. 125.75° ± 26.44°), rotation arc (165.71° ± 20.34° vs. 157.04° ± 26.84°), MEPS (97.86 ± 7.26 vs. 95.21 ± 11.28), functional elbow rate (93% vs. 79%), and complication rate (11% vs. 21%) remained similar, without significant differences (P > 0.05). During follow-up, one patient in the guide group required reoperation for heterotopic ossification, whereas three patients in the freehand group required reoperation for heterotopic ossification or fixator loosening. CONCLUSION: Compared with freehand localization of the rotation axis, guide-assisted localization reduced pin insertion time, fluoroscopic exposures, and pin adjustments. Furthermore, the guide group demonstrated non-inferiority in surgical outcomes compared to the freehand group.

Schlagwörter

Stichwörter der Autor:innen

Elbow fracturesExternal fixatorsOrthopedic proceduresPrintingPrognosisThree-dimensional

Autor:innen und Institutionen

  • Shandong Public Health Clinical Center, Shandong University, Jinan, China.
  • Shandong Public Health Clinical Center, Shandong University, Jinan, China. gaohongwei202210@163.com.
  • Shandong Public Health Clinical Center, Shandong University, Jinan, China. mapengcheng0518@163.com.

Zitieren

APA

Chen, H., Zhao, T., Gao, H., & Ma, P. (2026). The effect of three dimensional-printed guides on assisting rotational axis localization of hinged external fixator in the surgery for elbow terrible triad injury. International Orthopaedics. https://doi.org/10.1007/s00264-026-07067-9

Vancouver

Chen H, Zhao T, Gao H, Ma P. The effect of three dimensional-printed guides on assisting rotational axis localization of hinged external fixator in the surgery for elbow terrible triad injury. International Orthopaedics. 2026. doi:10.1007/s00264-026-07067-9

BibTeX
@article{Chen2026,
  author = {Chen, Huizhi and Zhao, Tianyu and Gao, Hongwei and Ma, Pengcheng},
  title = {The effect of three dimensional-printed guides on assisting rotational axis localization of hinged external fixator in the surgery for elbow terrible triad injury},
  journal = {International Orthopaedics},
  year = {2026},
  doi = {10.1007/s00264-026-07067-9}
}
Kostenlos starten →