Robotic assistance reduces operative time variability in reverse shoulder arthroplasty: a retrospective single-surgeon study
International Orthopaedics · 2026-12 · 50 (12) · 3245-3249
DOI: 10.1007/s00264-026-07056-y ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift International Orthopaedics, online erschienen am 07.10.2026. Verfasst von Matthew Frederickson und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, UC Davis Health, Sacramento, United States. Matthewryan491@gmail.com. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Shoulder, Operative Time, Robotic Surgical Procedures. Die Arbeit nennt 14 Literaturangaben.
Abstract (Originalsprache)
Background
Robotic assistance for reverse total shoulder arthroplasty (rTSA) improves the accuracy and consistency of implant positioning, but whether this reproducibility extends to the surgical workflow is unknown. This study sought to compare operative time variability between conventional and robotic-assisted rTSA using the Mako robotic system (Stryker, Kalamazoo, MI).
Methods
We retrospectively reviewed consecutive elective primary rTSAs performed by a single fellowship-trained shoulder surgeon. Operative time was defined as incision start to incision closure. The first 23 robotic-assisted cases using the Mako robotic system were designated the learning phase based on a prior internal operative time learning curve analysis and were excluded. Post-learning curve robotic-assisted cases were compared with conventional cases from the same period. The primary outcome was operative time variability, quantified using the standard deviation (SD) and coefficient of variation, and compared with the Brown-Forsythe test and the variance ratio with 95% confidence interval (CI). Native glenoid retroversion and RSA angle were compared as markers of case complexity.
Results
Thirty-nine robotic-assisted cases were compared with 38 conventional cases. Robotic operative time was substantially less variable than conventional operative time (SD 9.9 vs. 19.7 min; coefficient of variation 13.3% vs. 25.0%; variance ratio 4.01; 95% CI, 2.09–7.69; Brown-Forsythe P < .001), while mean operative time was equivalent (74.2 vs. 78.8 min; P = .20). The groups did not differ in native glenoid retroversion (9.2° vs. 8.7°; P = .77) or RSA angle (14.3° vs. 15.1°; P = .57).
Conclusion
Robotic-assisted rTSA was associated with more consistent operative times than conventional rTSA, with no significant difference in mean operative time. These findings suggest that the value of robotic assistance in rTSA may extend beyond implant positioning to the reproducibility of surgical workflow.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopaedic Surgery, UC Davis Health, Sacramento, United States. Matthewryan491@gmail.com.
- Department of Orthopaedic Surgery, UC Davis Health, Sacramento, United States. dsing@health.ucdavis.edu.
- Department of Orthopaedic Surgery, UC Davis Health, Sacramento, United States. marianofurrer@gmail.com.
ORCID-Profile: Dilpreet Singh
Zitieren
APA
Frederickson, M., Singh, D., & Menendez, M. E. (2026). Robotic assistance reduces operative time variability in reverse shoulder arthroplasty: a retrospective single-surgeon study. International Orthopaedics, 50(12), 3245-3249. https://doi.org/10.1007/s00264-026-07056-y
Vancouver
Frederickson M, Singh D, Menendez ME. Robotic assistance reduces operative time variability in reverse shoulder arthroplasty: a retrospective single-surgeon study. International Orthopaedics. 2026;50(12):3245-3249. doi:10.1007/s00264-026-07056-y
BibTeX
@article{Frederickson2026,
author = {Frederickson, Matthew and Singh, Dilpreet and Menendez, Mariano E},
title = {Robotic assistance reduces operative time variability in reverse shoulder arthroplasty: a retrospective single-surgeon study},
journal = {International Orthopaedics},
year = {2026},
volume = {50},
number = {12},
pages = {3245--3249},
doi = {10.1007/s00264-026-07056-y}
}
EUVIMED