Effect of native Posterior condylar axis-Transepicondylar axis variability on femoral component rotation using robotic total knee arthroplasty
International Orthopaedics · 2026-12 · 50 (12) · 3135-3140
DOI: 10.1007/s00264-026-07018-4 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Orthopaedics, online erschienen am 08.09.2026. Verfasst von Prashant Tank und 5 weiteren Autor:innen. Beteiligte Einrichtung: All India Institute of Medical Sciences, New Delhi, India. prashanttank12@gmail.com. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Robotic Surgical Procedures, Femur, Osteoarthritis, Knee. Die Arbeit nennt 16 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: Accurate femoral component rotation in total knee arthroplasty (TKA) is critical for flexion balance, patellofemoral tracking, and implant longevity. Conventional techniques apply a fixed 3° external rotation relative to the posterior condylar axis (PCA), assuming a constant relationship with the transepicondylar axis (TEA). However, anatomical variability challenges this assumption. This study evaluated whether robotic-assisted TKA individualizes femoral rotation according to native PCA-TEA anatomy rather than applying a fixed rotational target. MATERIALS AND METHODS: This retrospective study included 52 patients (72 knees) undergoing primary CT-based robot (MAKO) assisted TKA for primary osteoarthritis of the knee. Preoperative CT scans were used to determine the native PCA-TEA angle. Intraoperative femoral component rotation relative to PCA and TEA was recorded using robot-generated measurements. Correlations were assessed using Spearman's coefficient, with subgroup analysis across PCA-TEA strata. RESULTS: The median PCA-TEA angle was 2.3° (range -1.9 to 8.7°). Median femoral rotation was 3.9° (range -1.2 to 9.6°) relative to PCA and 1.1° (range -3.4 to 4.9°) relative to TEA. A strong positive correlation existed between PCA-TEA angle and rotation relative to PCA (ρ = 0.8, p < 0.001), while a moderate negative correlation was observed relative to TEA (ρ = -0.5, p < 0.001). Knees with negative PCA-TEA anatomy demonstrated significantly lower rotation than the conventional 3° target (p < 0.05). CONCLUSION: Robotic functional alignment adapts femoral component rotation to native PCA-TEA anatomy within predefined rotational boundaries rather than adhering to a fixed 3° paradigm. While this demonstrates patient-specific rotational adaptation, whether such adaptation provides a clinical benefit remains to be demonstrated.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- All India Institute of Medical Sciences, New Delhi, India. prashanttank12@gmail.com.
- All India Institute of Medical Sciences, New Delhi, India.
ORCID-Profile: Nitin Chauhan, Harsh Jain
Zitieren
APA
Tank, P., Chauhan, N., Jain, H., Jha, T., Shankar, V., & Kumar, V. (2026). Effect of native Posterior condylar axis-Transepicondylar axis variability on femoral component rotation using robotic total knee arthroplasty. International Orthopaedics, 50(12), 3135-3140. https://doi.org/10.1007/s00264-026-07018-4
Vancouver
Tank P, Chauhan N, Jain H, Jha T, Shankar V, Kumar V. Effect of native Posterior condylar axis-Transepicondylar axis variability on femoral component rotation using robotic total knee arthroplasty. International Orthopaedics. 2026;50(12):3135-3140. doi:10.1007/s00264-026-07018-4
BibTeX
@article{Tank2026,
author = {Tank, Prashant and Chauhan, Nitin and Jain, Harsh and Jha, Tejaswin and Shankar, Vivek and Kumar, Vijay},
title = {Effect of native Posterior condylar axis-Transepicondylar axis variability on femoral component rotation using robotic total knee arthroplasty},
journal = {International Orthopaedics},
year = {2026},
volume = {50},
number = {12},
pages = {3135--3140},
doi = {10.1007/s00264-026-07018-4}
}
EUVIMED