Reconstruction of the hip in congenital femoral deficiency: a three year follow-up
International Orthopaedics · 2026-12 · 50 (12) · 3319-3328
DOI: 10.1007/s00264-026-06989-8 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Orthopaedics, online erschienen am 24.08.2026. Verfasst von Mostafa Hammad und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedic Surgery, Tanta University, Tanta, Egypt. mostafa.hammad2@outlook.com. Hauptthemen laut MEDLINE: Hip Joint, Femur, Plastic Surgery Procedures. Die Arbeit nennt 29 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Congenital femoral deficiency (CFD) has many anatomical variations. A management-oriented classification offers greater clinical value. The SUPERhip reconstruction procedure was developed based on Paley's classification, though reports on its outcome remain limited. PURPOSE: Our aim in this study was to evaluate the radiographic and range of motion outcomes after hip reconstruction in CFD using the SUPERhip technique. METHODS: This is a prospective case series that included 12 patients with unilateral CFD type one who underwent hip reconstruction using the SUPERhip 1 procedure, with at least a three-year follow-up. Bilateral cases, neck pseudarthrosis, diaphyseal deficiency, and cases with previous hip surgery were excluded. Average follow-up was 41.5 months. Radiographs were used for evaluation of the neck shaft angle (NSA), acetabular index (AI), and lateral centre edge angle. Range of motion (ROM) was evaluated using Children's Hospital Oakland Hip Evaluation Scale (CHOES). Non-parametric tests were used for statistical analysis. RESULTS: The postoperative range of motion scores were excellent in four cases, good in seven cases, and fair in one case. Eight cases underwent pelvic osteotomy, post-operative AI and LCEA were within the accepted degrees for all cases. Neck shaft angle regressed toward varus in four cases (average 13°) after plate removal. One case developed a deep infection requiring debridement. Persistent hip flexion was present in two cases (15°, 25°). Five cases underwent lengthening; no hip dislocations or changes in AI or LCEA were encountered during or after lengthening. Age, sex, and CFD type did not influence the final clinical outcome or the varus recurrence. CONCLUSION: The radiographic outcome and range of motion after the SUPERhip 1 technique for type 1 CFD yielded good to excellent results in 91.6%. The procedure was found to be reliable and reproducible with an acceptable complication rate. The varus recurrence remains a problem.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopedic Surgery, Tanta University, Tanta, Egypt. mostafa.hammad2@outlook.com.
- Department of Orthopedic Surgery, Tanta University, Tanta, Egypt.
- Department of Diagnostic Radiology, Tanta University, Tanta, Egypt.
Zitieren
APA
Hammad, M., El-Sayed, M., Dawoud, B., Mahmoud, A., Fadel, M., Elmehy, E., & Nada, A. (2026). Reconstruction of the hip in congenital femoral deficiency: a three year follow-up. International Orthopaedics, 50(12), 3319-3328. https://doi.org/10.1007/s00264-026-06989-8
Vancouver
Hammad M, El-Sayed M, Dawoud B, Mahmoud A, Fadel M, Elmehy E, et al. Reconstruction of the hip in congenital femoral deficiency: a three year follow-up. International Orthopaedics. 2026;50(12):3319-3328. doi:10.1007/s00264-026-06989-8
BibTeX
@article{Hammad2026,
author = {Hammad, Mostafa and El-Sayed, Mohamed and Dawoud, Basant and Mahmoud, Ashraf and Fadel, Moheb and Elmehy, Emad and Nada, Abdullah},
title = {Reconstruction of the hip in congenital femoral deficiency: a three year follow-up},
journal = {International Orthopaedics},
year = {2026},
volume = {50},
number = {12},
pages = {3319--3328},
doi = {10.1007/s00264-026-06989-8}
}
EUVIMED