Navicular bone morphometry for implant planning in fracture surgery: a dry bone analysis
International Orthopaedics · 2026-07 · 50 (7) · 1597-1604
DOI: 10.1007/s00264-026-06889-x ↗Kurz gefasst
Fachartikel in der Zeitschrift International Orthopaedics, online erschienen am 06.06.2026. Verfasst von Helin Yücedağ Gündoğdu und 1 weiteren Autor:innen. Beteiligte Einrichtung: Hacettepe University, Ankara, Turkey. yucedaghelin@gmail.com. Hauptthemen laut MEDLINE: Tarsal Bones, Fractures, Bone, Fracture Fixation, Internal. Die Arbeit nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Hacettepe University.
Abstract (Originalsprache)
Objective
The purpose of this study is to quantitatively characterise surgically relevant morphometric features of dry navicular bones and to provide anatomical reference values that can be utilised in implant placement.
Methods
Fifty-five isolated, unpaired dry navicular bones without macroscopic deformity were examined. Tuberosity morphology, tuberosity–medial cuneiform distances, navicular body dimensions (mediolateral width, level-specific anteroposterior measurements, and depth), talonavicular articular surface depth, and concavity index were evaluated using a digital caliper and digital thickness gauge.
Results
The narrowest tuberosity width, anteroposterior length, and supero-inferior height were 6.59 ± 1.28 mm, 16.38 ± 2.43 mm, and 11.24 ± 1.26 mm, respectively. The tuberosity groove depth was 2.05 ± 0.92 mm. The distances from the tuberosity midpoint to the medial cuneiform articular surface at the nearest and farthest points were 21.86 ± 3.11 mm, 29.65 ± 3.37 mm. The mean mediolateral body width was 37.69 ± 3.54 mm. Level-specific anteroposterior dimensions were 18.01 ± 2.34 mm, 15.15 ± 2.15 mm, and 12.56 ± 1.62 mm, whereas the corresponding body depths were 18.35 ± 3.01 mm, 25.24 ± 2.30 mm, and 22.52 ± 2.47 mm, respectively.
Conclusion
These findings provide surgically relevant anatomical reference values that may assist preoperative planning and support safer fixation of navicular fractures, and contribute to the design and optimisation of navicular implants and fixation devices.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Hacettepe University, Ankara, Turkey. yucedaghelin@gmail.com.
- Hacettepe University, Ankara, Turkey. bahattin.pasli@hacettepe.edu.tr.
Förderung
- Hacettepe University
Zitieren
APA
Yücedağ Gündoğdu, H., & Paslı, B. (2026). Navicular bone morphometry for implant planning in fracture surgery: a dry bone analysis. International Orthopaedics, 50(7), 1597-1604. https://doi.org/10.1007/s00264-026-06889-x
Vancouver
Yücedağ Gündoğdu H, Paslı B. Navicular bone morphometry for implant planning in fracture surgery: a dry bone analysis. International Orthopaedics. 2026;50(7):1597-1604. doi:10.1007/s00264-026-06889-x
BibTeX
@article{YcedaGndodu2026,
author = {Yücedağ Gündoğdu, Helin and Paslı, Bahattin},
title = {Navicular bone morphometry for implant planning in fracture surgery: a dry bone analysis},
journal = {International Orthopaedics},
year = {2026},
volume = {50},
number = {7},
pages = {1597--1604},
doi = {10.1007/s00264-026-06889-x}
}