EUVIMEDEUVIMED entdecken
Vergleichsstudie

Robotic-assisted total knee arthroplasty reduces alignment variability and rotational outliers compared with conventional techniques

Francisco Endara Urresta, Carlos Peñaherrera-Carrillo, Alejandro Barros Castro, Prof Sébastien Lustig Md PhD

International Orthopaedics · 2026-05 · 50 (5) · 1069-1076

DOI: 10.1007/s00264-026-06800-8 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift International Orthopaedics, online erschienen am 14.04.2026. Verfasst von Francisco Endara Urresta und 3 weiteren Autor:innen. Beteiligte Einrichtung: Specialist in Orthopedics and Traumatology, Clínica Arthros, Quito, Ecuador. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Robotic Surgical Procedures, Knee Joint, Bone Malalignment. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 28 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

INTRODUCTION: Precise component positioning in total knee arthroplasty (TKA) influences tibiofemoral mechanics, patellofemoral tracking, and soft-tissue balance. Although robotic-assisted TKA improves alignment accuracy, most comparative studies emphasize mean alignment rather than surgical reproducibility. Variability and outlier rates may better reflect precision. This study compared alignment variability and the proportion of coronal and rotational outliers between robotic-assisted and conventional TKA performed under identical mechanical alignment targets. METHODS: A retrospective comparative cohort included 300 primary TKAs (150 robotic-assisted, 150 conventional) performed by the same surgical team between 2022 and 2025. Postoperative hip-knee-ankle (HKA) alignment was measured on standardized long-leg radiographs. Rotational alignment was evaluated by computed tomography in a predefined subgroup. Variability was quantified using standard deviation and equality of variance tested with the Brown-Forsythe method. Outliers were defined as deviation > 3° from target alignment. Multivariable logistic regression identified predictors of outlier status. RESULTS: Mean postoperative HKA did not differ between groups (0.4° ± 1.6° robotic vs. 0.6° ± 2.8° conventional; p = 0.41). Robotic-assisted TKA showed lower dispersion (SD 1.6° vs. 2.8°; p 3° was less frequent with robotic assistance (8.7% vs. 24.0%; p = 0.006). CONCLUSIONS: Robotic-assisted TKA reduced alignment variability and outliers without altering mean alignment, suggesting improved surgical reproducibility.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneeRobotic Surgical ProceduresKnee JointBone MalalignmentHumansRetrospective StudiesFemaleMaleAgedReproducibility of ResultsRotationOsteoarthritis, KneeTomography, X-Ray Computed

Stichwörter der Autor:innen

Alignment variabilityRobotic-assisted surgeryRotational outliersSurgical precisionTotal knee arthroplasty

Autor:innen und Institutionen

  • Specialist in Orthopedics and Traumatology, Clínica Arthros, Quito, Ecuador.
  • Hip and Knee Reconstruction, Hospital Vozandes, Quito, Ecuador. carlospenaherrerac@gmail.com.
  • Resident in Orthopedics and Traumatology, Universidad Internacional del Ecuador, Quito, Ecuador.
  • Knee and Hip Arthroplasty Surgery. Arthritis and Joint Replacement Department (Chair)., Hospices Civils de Lyon, Lyon, France.

Zitieren

APA

Endara Urresta, F., Peñaherrera-Carrillo, C., Barros Castro, A., & Lustig Md PhD, P. S. (2026). Robotic-assisted total knee arthroplasty reduces alignment variability and rotational outliers compared with conventional techniques. International Orthopaedics, 50(5), 1069-1076. https://doi.org/10.1007/s00264-026-06800-8

Vancouver

Endara Urresta F, Peñaherrera-Carrillo C, Barros Castro A, Lustig Md PhD PS. Robotic-assisted total knee arthroplasty reduces alignment variability and rotational outliers compared with conventional techniques. International Orthopaedics. 2026;50(5):1069-1076. doi:10.1007/s00264-026-06800-8

BibTeX
@article{EndaraUrresta2026,
  author = {Endara Urresta, Francisco and Peñaherrera-Carrillo, Carlos and Barros Castro, Alejandro and Lustig Md PhD, Prof Sébastien},
  title = {Robotic-assisted total knee arthroplasty reduces alignment variability and rotational outliers compared with conventional techniques},
  journal = {International Orthopaedics},
  year = {2026},
  volume = {50},
  number = {5},
  pages = {1069--1076},
  doi = {10.1007/s00264-026-06800-8}
}
Kostenlos starten →