Tourniquet-less total knee arthroplasty does not negatively affect cement penetration: a double-blinded randomized controlled trial
International Orthopaedics · 2025-10 · 49 (10) · 2443-2451
DOI: 10.1007/s00264-025-06635-9 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift International Orthopaedics, online erschienen am 13.08.2025. Verfasst von Seyed Mohammad Javad Mortazavi und 6 weiteren Autor:innen. Beteiligte Einrichtung: Joint Reconstruction Research Center, Tehran University of Medical Sciences, Tehran, Islamic Republic of Iran. smjmort@yahoo.com. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Tourniquets, Bone Cements, Osteoarthritis, Knee. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 37 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: The use of tourniquets in total knee arthroplasty (TKA) remains controversial, with growing interest in tourniquet-less techniques to improve patient outcomes. However, concerns persist regarding the adequacy of cement penetration and long-term implant stability. This study evaluated whether tourniquet-less TKA compromises cement penetration compared to conventional tourniquet-assisted procedures. METHODS: A double-blind randomized controlled trial included 120 patients with end-stage osteoarthritis undergoing cemented TKA. Patients were randomized into two groups: tourniquet (n = 60) and tourniquet-less (n = 60). All patients received standardized protocols including tranexamic acid, spinal anaesthesia with controlled hypotension, and identical cementing techniques. The primary outcome was cement penetration depth measured on standardized radiographs at 60 days. Secondary analysis assessed the impact of bone mineral density on cement penetration. RESULTS: Both groups achieved optimal cement penetration (2–3 mm) across the measured zones, with no clinically significant differences in average penetration depth. Bone mineral density did not affect penetration in either group, with 28.9% of patients having osteoporosis. Statistically significant differences in select zones (0.06–0.5 mm) were not clinically meaningful. CONCLUSIONS: Tourniquet-less TKA achieves equivalent cement penetration to tourniquet-assisted procedures when performed with modern standardized techniques. These findings support surgical decision-making for tourniquet-less approaches without compromising implant fixation quality, potentially enabling improved patient-centered outcomes.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Joint Reconstruction Research Center, Tehran University of Medical Sciences, Tehran, Islamic Republic of Iran. smjmort@yahoo.com.
- Department of Orthopedic Surgery, Imam Khomeini Hospital Complex, Tehran, Islamic Republic of Iran. smjmort@yahoo.com.
- Joint Reconstruction Research Center, Tehran University of Medical Sciences, Tehran, Islamic Republic of Iran.
- Department of Orthopedic Surgery, Imam Khomeini Hospital Complex, Tehran, Islamic Republic of Iran.
- Shohadaye Tajrish Hospital, Shahid Beheshti University of Medical Sciences, Tehran, Islamic Republic of Iran.
Zitieren
APA
Mortazavi, S. M. J., Rezaee, H., Seyedtabaei, S. M. M., Nafisi, M., Shayani, P. J., Razzaghof, M., & Firoozabadi, M. A. (2025). Tourniquet-less total knee arthroplasty does not negatively affect cement penetration: a double-blinded randomized controlled trial. International Orthopaedics, 49(10), 2443-2451. https://doi.org/10.1007/s00264-025-06635-9
Vancouver
Mortazavi SMJ, Rezaee H, Seyedtabaei SMM, Nafisi M, Shayani PJ, Razzaghof M, et al. Tourniquet-less total knee arthroplasty does not negatively affect cement penetration: a double-blinded randomized controlled trial. International Orthopaedics. 2025;49(10):2443-2451. doi:10.1007/s00264-025-06635-9
BibTeX
@article{Mortazavi2025,
author = {Mortazavi, Seyed Mohammad Javad and Rezaee, Hesan and Seyedtabaei, Seyed Mohammad Milad and Nafisi, Maziar and Shayani, Parva Javan and Razzaghof, Mohammadreza and Firoozabadi, Mohammad Ayati},
title = {Tourniquet-less total knee arthroplasty does not negatively affect cement penetration: a double-blinded randomized controlled trial},
journal = {International Orthopaedics},
year = {2025},
volume = {49},
number = {10},
pages = {2443--2451},
doi = {10.1007/s00264-025-06635-9}
}