Enhanced accuracy and reduced complications: robot-assisted navigation for retrograde intramedullary nailing in distal femoral fractures
International Orthopaedics · 2025
DOI: 10.1007/s00264-025-06544-x ↗Kurz gefasst
Fachartikel in der Zeitschrift International Orthopaedics, 2025. Verfasst von Quanjie He und 5 weiteren Autor:innen. Beteiligte Einrichtung: Clinical School/College of Orthopedics, Tianjin Medical University, Tianjin, China. Hauptthemen laut MEDLINE: Fracture Fixation, Intramedullary, Femoral Fractures, Robotic Surgical Procedures, Postoperative Complications. Die Arbeit nennt 29 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: This research investigates the benefits of robot-assisted navigation systems in retrograde intramedullary nailing for distal femoral fractures and contrasts their outcomes with conventional surgical methods. This is a retrospective clinical study designed to compare the outcomes of these two approaches. METHODS: This study included 56 distal femoral fracture patients treated between February 2020 and May 2023. Among them, 28 patients underwent robot-assisted retrograde intramedullary nailing (robot group), while 28 received conventional retrograde intramedullary nailing (traditional group). Surgical duration, intraoperative fluoroscopy frequency, number of guidewire insertions into the femoral medullary cavity, and intraoperative blood loss were recorded. Healing progress and fixation stability status were observed, and postoperative articular function was assessed using Neer's scoring system at a one year follow-up. RESULTS: Baseline characteristics were comparable between the two groups, showing no statistically significant differences.The robot group demonstrated shorter operative time, fewer guidewire placements, reduced intraoperative hemorrhage and incision size compared to the traditional group (P 0.05). CONCLUSION: Compared with traditional surgical methods, robot-assisted retrograde intramedullary fixation for fractures of the distal femur offers advantages of being minimally invasive, more precise, requiring shorter operative times, and resulting in reduced blood loss, fluoroscopy exposure, and guidewire insertion attempts. These benefits may contribute to a reduction in postoperative complications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Clinical School/College of Orthopedics, Tianjin Medical University, Tianjin, China.
- Department of Orthopedics, Affiliated Hospital of Hebei Engineering University, Handan, China.
- Department of Bone Tumor and Soft Tissue Oncology, Tianjin Hospital, Tianjin, China.
- Department of Bone Tumor and Soft Tissue Oncology, Tianjin Hospital, Tianjin, China. hyc1245844502@126.com.
Zitieren
APA
He, Q., Xie, Z., Zhang, J., Jiao, Y., Zhang, Y., & Hu, Y. (2025). Enhanced accuracy and reduced complications: robot-assisted navigation for retrograde intramedullary nailing in distal femoral fractures. International Orthopaedics. https://doi.org/10.1007/s00264-025-06544-x
Vancouver
He Q, Xie Z, Zhang J, Jiao Y, Zhang Y, Hu Y. Enhanced accuracy and reduced complications: robot-assisted navigation for retrograde intramedullary nailing in distal femoral fractures. International Orthopaedics. 2025. doi:10.1007/s00264-025-06544-x
BibTeX
@article{He2025,
author = {He, Quanjie and Xie, Zhitao and Zhang, Jingyu and Jiao, Yongqiang and Zhang, Yongtao and Hu, Yongcheng},
title = {Enhanced accuracy and reduced complications: robot-assisted navigation for retrograde intramedullary nailing in distal femoral fractures},
journal = {International Orthopaedics},
year = {2025},
doi = {10.1007/s00264-025-06544-x}
}
EUVIMED