Better radiological outcomes but equal clinical function of a novel knee arthroplasty robot system: a prospective randomized controlled trial
International Orthopaedics · 2025
DOI: 10.1007/s00264-025-06523-2 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift International Orthopaedics, 2025. Verfasst von Xiao Geng und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedics, Peking University Third Hospital, Beijing, China. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Knee Joint, Osteoarthritis, Knee, Robotic Surgical Procedures. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 28 Literaturangaben. Gefördert von: Beijing Natural Science Foundation, Clinical Cohort Construction Program of Peking University Third Hospital.
Abstract (Originalsprache)
PURPOSE: This study aimed to evaluate the early clinical and radiological outcomes of robot assisted total knee arthroplasty, and to determine the efficiency and safety of its bone resection and implant positioning of the novel robot system. METHODS: 144 patients who underwent primary TKA were enrolled in this prospective, multicenter RCT conducted in three hospitals. five patients were lost to follow-up at six weeks after surgery. Therefore, 139 patients (73 in the RA TKA group and 66 in the CI TKA group) remained in the final analysis. The primary outcome was the rate of patients whose postoperative alignment was less than 3° deviated from the planned evaluated by full-length weight-bearing X-rays of the lower limb at 12 weeks postoperatively. Secondary outcomes included coronal and sagittal alignment of the components, operation times, blood loss, 12-week range of motion(ROM), 12-week postoperative functional outcomes and satisfaction evaluated by the American Knee Society Score (KSS) and the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) and adverse events (AEs). RESULTS: At 12 weeks postoperatively, we found the rate of radiographic inliers was significantly higher in the RA TKA group (90.4% vs. 59.1%; p < 0.05). The difference between planned and postoperative frontal femoral component (FFC) angle, frontal tibia component (FTC) angle and lateral femoral component (LFC) angle are significantly smaller in the RA TKA group (p < 0.05). The operation time was significantly longer in the RA TKA group than in the CI TKA group (133.01 vs. 92.33 min; p < 0.05). There was no significant difference in blood loss, 12-week ROM, 12-week postoperative functional outcomes and satisfaction evaluated by KSS and WOMAC scores. There were no AEs or SAEs that were determined to be "related" to the robotic system. CONCLUSION: The novel robot assisted TKA is safe and more precise in bone resection and implant positioning as demonstrated in this trial.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopedics, Peking University Third Hospital, Beijing, China.
- Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Beijing, China.
- Department of Joint and Sport Medicine, Tianjin Union Medical Center, Nankai University Affiliated People's Hospital, Tianjin, China.
- Department of Orthopaedics, Tianjin Fourth Central Hospital, Tianjin, China.
- Department of Orthopedics, Peking University Third Hospital, Beijing, China. li_zijian@bjmu.edu.cn.
- Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Beijing, China. li_zijian@bjmu.edu.cn.
Förderung
- Beijing Natural Science Foundation
- Clinical Cohort Construction Program of Peking University Third Hospital
Zitieren
APA
Geng, X., Dong, Z., Chen, J., Tian, M., Wang, Y., Ren, Y., Zhao, Z., Zhang, Y., Wang, X., Wang, C., Li, Z., & Tian, H. (2025). Better radiological outcomes but equal clinical function of a novel knee arthroplasty robot system: a prospective randomized controlled trial. International Orthopaedics. https://doi.org/10.1007/s00264-025-06523-2
Vancouver
Geng X, Dong Z, Chen J, Tian M, Wang Y, Ren Y, et al. Better radiological outcomes but equal clinical function of a novel knee arthroplasty robot system: a prospective randomized controlled trial. International Orthopaedics. 2025. doi:10.1007/s00264-025-06523-2
BibTeX
@article{Geng2025,
author = {Geng, Xiao and Dong, Ziyang and Chen, Jiazheng and Tian, Mengqiang and Wang, Yongqing and Ren, Yiming and Zhao, Zhihui and Zhang, Yipu and Wang, Xinguang and Wang, Cheng and Li, Zijian and Tian, Hua},
title = {Better radiological outcomes but equal clinical function of a novel knee arthroplasty robot system: a prospective randomized controlled trial},
journal = {International Orthopaedics},
year = {2025},
doi = {10.1007/s00264-025-06523-2}
}
EUVIMED