EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Preoperative evaluation of femoral and tibial sagittal alignment in robotic-assisted and conventional total knee arthroplasty and consequences for practice

Yue Peng, Ran Ding, Ming Li, Guangxue Wang, Zikang Zhong, Lingbo Wei, Cheng Huang, Nianfei Zhang, Philippe Hernigou, Weiguo Wang iD

International Orthopaedics · 2024-08 · 48 (8) · 2047-2054

DOI: 10.1007/s00264-024-06229-x ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift International Orthopaedics, online erschienen am 29.05.2024. Verfasst von Yue Peng und 9 weiteren Autor:innen. Beteiligte Einrichtung: China-Japan Friendship Hospital (Institute of Clinical Medical Sciences), Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing…. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Tibia, Femur, Robotic Surgical Procedures. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Robot-assisted total knee arthroplasty (TKA) was developed to improve the precision and accuracy of implant placement in conventional TKA. However, the angular differences between referenced axes in robot-assisted TKA and conventional TKA remain unclear. The aim of this study was to investigate the angular differences in sagittal alignment between robot-assisted TKA and conventional TKA for both the femur and the tibia and to discuss their clinical implications.

Methods

We conducted a retrospective analysis of data from 100 patients (97 patients) who underwent computed tomography (CT) for Mako TKA. We measured the angle between the robot femoral axis (RFA) and conventional femoral axis (CFA) in the sagittal plane and the angle between the robot tibial axis (RTA) and the conventional tibial axis (CTA). Angles were compared between the sexes. Correlation analysis was conducted between the angles and height.

Results

In the sagittal plane, the mean RFA-CFA angle was 2.2° ± 1.6°, and the mean RTA-CTA angle was 2.3° ± 1.6°. There were no significant differences between the two angles among males and females (p > 0.05). There was a correlation between the RFA-CFA angle and RTA-CTA angle ( p < 0.001, r = 0.33), and there was a correlation between height and the combination of the RFA-CFA angle and RTA-CTA angle ( p = 0.03, r = 0.22).

Conclusion

There are angular differences between the axes referenced by robot-assisted TKA and those referenced by conventional TKA, which may be influenced by patient height. Correctly understanding these differences is crucial when evaluating the implant position and surgical outcomes after robot-assisted TKA. Furthermore, caution should be taken when assessing the flexion–extension angle of the knee since the angles displayed in the Mako system are different from the angles measured with intramedullary anatomical axes. After all, sagittal alignment principles differ between robot-assisted and conventional TKA; however, further studies are required to determine which principle is more appropriate or to modify these principles.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneeTibiaFemurRobotic Surgical ProceduresHumansMaleFemaleRetrospective StudiesAgedMiddle AgedTomography, X-Ray ComputedKnee JointAged, 80 and overOsteoarthritis, Knee

Stichwörter der Autor:innen

Angular differencesKnee arthroplastyRobotic surgerySagittal alignment

Autor:innen und Institutionen

  • China-Japan Friendship Hospital (Institute of Clinical Medical Sciences), Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, China.
  • Department of Orthopaedic Surgery, China-Japan Friendship Hospital, No.2 Yinghuayuan East Street, Chaoyang District, Beijing, 100029, China.
  • Peking University China-Japan Friendship School of Clinical Medicine, Beijing, China.
  • Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College (CAMS & PUMC), Beijing, China.
  • Department of Orthopaedic Surgery, University Paris East (UPEC), Hôpital Henri Mondor, Creteil, France. philippe.hernigou@wanadoo.fr.
  • Department of Orthopaedic Surgery, China-Japan Friendship Hospital, No.2 Yinghuayuan East Street, Chaoyang District, Beijing, 100029, China. jointwwg@163.com.

ORCID-Profile: Weiguo Wang

Zitieren

APA

Peng, Y., Ding, R., Li, M., Wang, G., Zhong, Z., Wei, L., Huang, C., Zhang, N., Hernigou, P., & Wang, W. (2024). Preoperative evaluation of femoral and tibial sagittal alignment in robotic-assisted and conventional total knee arthroplasty and consequences for practice. International Orthopaedics, 48(8), 2047-2054. https://doi.org/10.1007/s00264-024-06229-x

Vancouver

Peng Y, Ding R, Li M, Wang G, Zhong Z, Wei L, et al. Preoperative evaluation of femoral and tibial sagittal alignment in robotic-assisted and conventional total knee arthroplasty and consequences for practice. International Orthopaedics. 2024;48(8):2047-2054. doi:10.1007/s00264-024-06229-x

BibTeX
@article{Peng2024,
  author = {Peng, Yue and Ding, Ran and Li, Ming and Wang, Guangxue and Zhong, Zikang and Wei, Lingbo and Huang, Cheng and Zhang, Nianfei and Hernigou, Philippe and Wang, Weiguo},
  title = {Preoperative evaluation of femoral and tibial sagittal alignment in robotic-assisted and conventional total knee arthroplasty and consequences for practice},
  journal = {International Orthopaedics},
  year = {2024},
  volume = {48},
  number = {8},
  pages = {2047--2054},
  doi = {10.1007/s00264-024-06229-x}
}
Kostenlos starten →