Optimising safe margins in shoulder surgeries: a cadaveric study on brachial plexus nerves with anthropometric and movement correlation
International Orthopaedics · 2024
DOI: 10.1007/s00264-024-06163-y ↗Kurz gefasst
Fachartikel in der Zeitschrift International Orthopaedics, 2024. Verfasst von K Kodandapani und 3 weiteren Autor:innen. Beteiligte Einrichtung: Orthopaedic Dept., Osmania General Hospital, Hyderabad, 500012, India. Hauptthemen laut MEDLINE: Cadaver, Brachial Plexus, Humerus. Die Arbeit nennt 23 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: Shoulder surgeries, vital for diverse pathologies, pose a risk of iatrogenic nerve damage. Existing literature lacks diverse bone landmark-specific nerve position data. The purpose of this study is to address this gap by investigating such relationships. METHOD: This cadaveric study examines axillary, radial and suprascapular nerves' relation with acromion, coracoid and greater tuberosity of the humerus (GT). It also correlates this data with humeral lengths and explores nerve dynamics in relation to arm positions. RESULTS: The mean distance from the axillary nerve to (i) GT was 4.38 cm (range 3.32-5.44, SD 0.53), (ii) acromion was 6.42 cm (range 5.03-7.8, SD 0.694) and (iii) coracoid process was 4.3 cm (range 2.76-5.84, SD 0.769). Abduction brought the nerve closer by 0.36 cm, 0.35 cm and 0.53 cm, respectively. The mean distance from radial nerve to (i) GT was 5.46 cm (range 3.78-7.14, SD 0.839), (ii) acromion was 7.82 cm (range 5.4-10.24, SD 1.21) and (iii) tip of the coracoid process was 6.09 cm (range 4.07-8.11 cm, SD 1.01). The mean distance from the suprascapular nerve to the acromion was 4.2 cm (range 3.1-5.4, SD 0.575). The mean humeral length was noted to be 27.83 cm (range 25.3-30.7, SD 1.13). There was no significant correlation between these distances and humeral lengths. CONCLUSION: It is essential to exercise caution to avoid axillary nerve damage during the abduction manoeuvre, as its distance from the greater tuberosity and tip of the coracoid process has shown a significant reduction. The safe margins, in relation to the length of the humerus and consequently the patient's stature, exhibit no significant variation. In situations where the greater tuberosity (GT) and the border of the acromion are inaccessible due to reasons such as trauma, the tip of the coracoid process can serve as a dependable bone landmark for establishing a secure surgical margin.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Orthopaedic Dept., Osmania General Hospital, Hyderabad, 500012, India.
- Orthopaedic Dept., Osmania General Hospital, Hyderabad, 500012, India. mrbonesthehealer@gmail.com.
ORCID-Profile: Karthik Sangani
Zitieren
APA
Kodandapani, K., Sangani, K., Chakrapani, A., & Vedapriya, A. K. (2024). Optimising safe margins in shoulder surgeries: a cadaveric study on brachial plexus nerves with anthropometric and movement correlation. International Orthopaedics. https://doi.org/10.1007/s00264-024-06163-y
Vancouver
Kodandapani K, Sangani K, Chakrapani A, Vedapriya AK. Optimising safe margins in shoulder surgeries: a cadaveric study on brachial plexus nerves with anthropometric and movement correlation. International Orthopaedics. 2024. doi:10.1007/s00264-024-06163-y
BibTeX
@article{Kodandapani2024,
author = {Kodandapani, K and Sangani, Karthik and Chakrapani, Arjun and Vedapriya, Aparna K},
title = {Optimising safe margins in shoulder surgeries: a cadaveric study on brachial plexus nerves with anthropometric and movement correlation},
journal = {International Orthopaedics},
year = {2024},
doi = {10.1007/s00264-024-06163-y}
}
EUVIMED