A formula for instability-related bone loss: estimating glenoid width and redefining bare spot
International Orthopaedics · 2024
DOI: 10.1007/s00264-024-06095-7 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Orthopaedics, 2024. Verfasst von Zhongkai Ren und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Sports Medicine, Affiliated Hospital of Qingdao University, Qingdao, Shandong, China. Hauptthemen laut MEDLINE: Shoulder Joint, Bone Diseases, Metabolic, Joint Instability, Glenoid Cavity. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Purpose
The aim of the study reveals a new intuitive method for preoperatively assessing defect ratio in glenoid deficiency based on the native glenoid width and the bare spot.
Methods
A linear relationship, i.e. the rh formula, between the native glenoid width (2 r ) and height ( h ) was revealed by a cadaver cohort ( n = 204). To validate the reliability of the rh formula, 280 3D-CT images of intact glenoids were recruited. To evaluate the accuracy of rh formula in estimating glenoid defect, the 65 anterior–inferior defect models were artificially established based on the 3D-CT images of intact glenoids. Moreover, a clinically common anterior–posterior (AP) method was compared with the rh formula, to verify the technical superiority of rh formula.
Results
The regression analysis indicated a linear relationship between the width and height of intact glenoid: 2 r = 0.768 × h − 1.222 mm ( R 2 = 0.820, p < 0.001). An excellent reliability was found between the formula prediction and model width ( ICC = 0.911, p = 0.266). An excellent agreement was found between the predicted values and model parameters (glenoid width, ICC rh = 0.967, p rh = 0.778; defect ratio, p rh = 0.572, ICC rh = 0.997). And, it is of higher accuracy compared to the AP method (glenoid width, ICC AP = 0.933, p AP = 0.001; defect ratio, ICC AP = 0.911, p AP = 0.033).
Conclusion
Applying the cadaver-based formula on 3D-CT scans accurately predicts native glenoid width and redefines bare spot for preoperatively determining glenoid bone loss.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Sports Medicine, Affiliated Hospital of Qingdao University, Qingdao, Shandong, China.
- School of Medicine, Nankai University, Tianjing, China.
- Medical Research Center, Shandong Institute of Traumatic Orthopedics, The Affiliated Hospital of Qingdao University, Qingdao, China.
- Department of Hand and Foot Surgery, The Affiliated Hospital of Qingdao University, Qingdao, China.
- Department of Orthopedics, The Third Hospital of Hebei Medical University, Shijiazhuang, China. dryzzhang@126.com.
- Department of Orthopedics, The Affiliated Hospital of Qingdao University, Qingdao, China. dryzzhang@126.com.
ORCID-Profile: Yingze Zhang, Tengbo Yu
Zitieren
APA
Ren, Z., Wang, F., Huang, X., Wang, J., Zhang, Y., & Yu, T. (2024). A formula for instability-related bone loss: estimating glenoid width and redefining bare spot. International Orthopaedics. https://doi.org/10.1007/s00264-024-06095-7
Vancouver
Ren Z, Wang F, Huang X, Wang J, Zhang Y, Yu T. A formula for instability-related bone loss: estimating glenoid width and redefining bare spot. International Orthopaedics. 2024. doi:10.1007/s00264-024-06095-7
BibTeX
@article{Ren2024,
author = {Ren, Zhongkai and Wang, Fengkun and Huang, Xiaohong and Wang, Jian and Zhang, Yingze and Yu, Tengbo},
title = {A formula for instability-related bone loss: estimating glenoid width and redefining bare spot},
journal = {International Orthopaedics},
year = {2024},
doi = {10.1007/s00264-024-06095-7}
}
EUVIMED