Restoration of constitutional alignment optimizes outcomes of computer navigated total knee arthroplasty: a prospective randomized controlled trial
International Orthopaedics · 2024-04 · 48 (4) · 971-981
DOI: 10.1007/s00264-024-06093-9 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift International Orthopaedics, online erschienen am 30.01.2024. Verfasst von Kai Zheng und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics, The First Affiliated Hospital of Soochow University, No.188 Shizi Street, Suzhou, China. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Osteoarthritis, Knee, Surgery, Computer-Assisted, Femoral Fractures. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 29 Literaturangaben. Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
PURPOSE: The value of computer navigation in total knee arthroplasty (TKA) for arthritic knees continues to be debated. The purpose of this study was to evaluate the value of navigated TKA associated with updated alignment philosophy. METHODS: This prospective randomized controlled trial enrolled 38 consecutive patients (76 knees) and were randomly assigned to both groups. The demographic data and perioperative data were recorded. The coronal plane alignment of the knee (CPAK) classification was used to classify knee alignment phenotypes. Radiographic outcomes were measured and subgroup analysis was further performed. Clinical outcomes were evaluated using patient-reported outcome measures (PROMs). Surgery-related complications were recorded. RESULTS: The distribution of CPAK phenotypes following constitutional aligned TKA was equivalent to the native cohort, whereas the mechanical aligned TKA dramatically altered the phenotype distribution from type I and type II to type V and type IV. Final implant positioning was different between groups, with constitutional aligned TKA having larger cTCA (P = .004), joint line obliquity (P = .006), joint line distance (P = .033) and smaller sFCA (P = .013). Subgroup analysis showed higher actual accuracy of component positioning was achieved in navigated TKA, especially in knees with deformity of > 10° (P < .05). Patients reported higher HSS score at three months postoperatively in constitutional aligned group (P = .002). One patient in navigated group suffered femoral pin site fracture caused by a minor trauma. CONCLUSION: Computer navigated TKA allows for restoration of constitutional alignment and minimizes soft tissue release, which when compared to mechanical alignment may be associated with superior early outcomes.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopaedics, The First Affiliated Hospital of Soochow University, No.188 Shizi Street, Suzhou, China.
- Department of Orthopedics, Wuxi Ninth People's Hospital Affiliated to Soochow University, Wuxi, China.
- Department of Orthopaedics, The First Affiliated Hospital of Soochow University, No.188 Shizi Street, Suzhou, China. xuyaozeng@163.com.
ORCID-Profile: Yaozeng Xu
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Zheng, K., Wang, Y., Wang, T., Zhu, F., Zhang, L., Li, R., Zhou, J., Geng, D., & Xu, Y. (2024). Restoration of constitutional alignment optimizes outcomes of computer navigated total knee arthroplasty: a prospective randomized controlled trial. International Orthopaedics, 48(4), 971-981. https://doi.org/10.1007/s00264-024-06093-9
Vancouver
Zheng K, Wang Y, Wang T, Zhu F, Zhang L, Li R, et al. Restoration of constitutional alignment optimizes outcomes of computer navigated total knee arthroplasty: a prospective randomized controlled trial. International Orthopaedics. 2024;48(4):971-981. doi:10.1007/s00264-024-06093-9
BibTeX
@article{Zheng2024,
author = {Zheng, Kai and Wang, Yijun and Wang, Tianhao and Zhu, Feng and Zhang, Lianfang and Li, Rongqun and Zhou, Jun and Geng, Dechun and Xu, Yaozeng},
title = {Restoration of constitutional alignment optimizes outcomes of computer navigated total knee arthroplasty: a prospective randomized controlled trial},
journal = {International Orthopaedics},
year = {2024},
volume = {48},
number = {4},
pages = {971--981},
doi = {10.1007/s00264-024-06093-9}
}
EUVIMED