Failure of the linkage mechanism in a semi-constrained total elbow arthroplasty is a rare and unpredictable event: a review of seven cases
International Orthopaedics · 2024
DOI: 10.1007/s00264-023-06015-1 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift International Orthopaedics, 2024. Verfasst von Po-An Chen und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedic Surgery and Comprehensive Sports Medicine Center, Chang Gung Memorial Hospital-Linkou, Taoyuan, Taiwan. Hauptthemen laut MEDLINE: Elbow Joint, Periprosthetic Fractures, Osteolysis, Arthroplasty, Replacement, Elbow. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 21 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: Linked component of total elbow arthroplasty (TEA) consisted of bushing and locking pins. Failure of linked components is a rare complication of TEA. This study aims to investigate the mechanism and consequence of failure of the linkage mechanism in TEA surgeries. METHODS: Between 2010 and 2021, five patients received revision operation due to linked component failure. Besides, two patients underwent primary operation at another institute were also analyzed due to failure of the linkage mechanism. RESULTS: All seven patients underwent primary TEA and mean age for primary TEA was 48 (range, 27-62). Two patients had TEA for post-traumatic arthritis, three patients for rheumatoid arthritis, and two patients for comminuted distal humerus fracture. The average time between primary TEA and revision TEA for linked component failure was 13.6 years. Three bushing wear and four locking pin dissociation were diagnosed according to pre-operative radiography. Elbow pain and swelling are the most common clinical symptoms. Severe osteolysis, periprosthetic fracture, and stem loosening were noted in three bushing wear cases. In four dissociation of locking pin cases, breakage of male locking pin phalanges was demonstrated in two patients. For revision procedures, both the locking pins and bushings were replaced. No patients in the study required additional surgery after the revision operation for linked component failure. CONCLUSION: Osteolysis, component loosening, periprosthetic fracture may be expected after linked component failure. Patients should be regularly followed up from short-term to long-term with radiography. Early diagnosis and intervention with linked component exchange can prevent extensive revision surgery.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopedic Surgery and Comprehensive Sports Medicine Center, Chang Gung Memorial Hospital-Linkou, Taoyuan, Taiwan.
- Department of Orthopedic Surgery and Comprehensive Sports Medicine Center, Chang Gung Memorial Hospital-Linkou, Taoyuan, Taiwan. bencycheng@gmail.com.
Zitieren
APA
Chen, P. A., Chen, A. C., & Cheng, C. Y. (2024). Failure of the linkage mechanism in a semi-constrained total elbow arthroplasty is a rare and unpredictable event: a review of seven cases. International Orthopaedics. https://doi.org/10.1007/s00264-023-06015-1
Vancouver
Chen PA, Chen AC, Cheng CY. Failure of the linkage mechanism in a semi-constrained total elbow arthroplasty is a rare and unpredictable event: a review of seven cases. International Orthopaedics. 2024. doi:10.1007/s00264-023-06015-1
BibTeX
@article{Chen2024,
author = {Chen, Po-An and Chen, Alvin Chao-Yu and Cheng, Chun-Ying},
title = {Failure of the linkage mechanism in a semi-constrained total elbow arthroplasty is a rare and unpredictable event: a review of seven cases},
journal = {International Orthopaedics},
year = {2024},
doi = {10.1007/s00264-023-06015-1}
}
EUVIMED