EUVIMEDEUVIMED entdecken
Crossref

Could a three-dimensional contralateral meniscus segmentation for allograft or scaffold sizing be possible? A prospective study

Valcarenghi Jérôme, Hernigou Jacques, Chahidi Esfandiar, Collard Xavier, Francotte Dorothée, Jennart Harold, Verdonk René

International Orthopaedics · 2023

DOI: 10.1007/s00264-023-05923-6 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Orthopaedics, 2023. Verfasst von Valcarenghi Jérôme und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics and Traumatology, Centre Hospitalier Universitaire d'Ambroise Paré, Hainaut, Belgium. jerome.valcarenghi@gmail.com. Hauptthemen laut MEDLINE: Menisci, Tibial, Imaging, Three-Dimensional, Tissue Scaffolds. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 34 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: Meniscal allografts and biodegradable meniscal implants are attractive surgical options for painful subtotal or total meniscectomies. In order to get the best results, these should be as similar as possible to the original meniscus in terms of shape, structure, and volume. Three-dimensional meniscus sizing could be an approach to improve the accuracy of meniscus matching. Therefore, the aims of this study were to perform a comparative morphological and volumetric analysis of the healthy meniscus based on manual tri-planar segmentation and to demonstrate that the menisci from the contralateral knee could be used as a reference in the sizing of a meniscal graft or a scaffold. METHODS: Three-dimensional meniscal models were created based on 120 MRIs in 60 healthy subjects (bilateral knees). The differences between the pairs of menisci concerning the widths, thicknesses, lateromedial distances, anteroposterior distances, angles of coverage, and meniscal volumes were evaluated. T-Student tests were used to compare the quantitative numerical variables of the different groups. Pearson's linear regression was used to determine if correlations existed between demographic variables (age, gender, height, weight) and anatomical parameters. Statistical significance was set at p < 0.05. RESULTS: Comparing the 120 pairs of menisci of each subject, there was no statistically significant difference for all parameters studied for both the medial and lateral meniscus. When the measurements were stratified by gender, statistically significant differences were observed for all parameters except meniscal coverage angles. We observed that anteroposterior and lateromedial distances were positively correlated with height and body mass index both at the level of the medial meniscus (r = 0.68; r = 0.66; r = 0.65; and r = 0.63) and lateral (r = 0.68; r = 0.69; r = 0.61; and r = 0.60). CONCLUSION: Our study demonstrated that the intra-individual 3D shapes of the left and right menisci are very similar. Therefore, the contralateral side could be used as a template for the 3D sizing of meniscal allografts or meniscal implants.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Menisci, TibialImaging, Three-DimensionalTissue ScaffoldsHumansFemaleMaleAdultProspective StudiesMagnetic Resonance ImagingMiddle AgedAllograftsYoung AdultTransplantation, HomologousKnee Joint

Stichwörter der Autor:innen

3D MRI segmentationKneeMeniscal allograft transplantationMeniscectomyMeniscus scaffold

Autor:innen und Institutionen

  • Department of Orthopaedics and Traumatology, Centre Hospitalier Universitaire d'Ambroise Paré, Hainaut, Belgium. jerome.valcarenghi@gmail.com.
  • Department of Orthopaedics and Traumatology, Centre Hospitalier EpiCURA, Hainaut, Belgium.
  • Department of Orthopaedics and Traumatology, Centre Hospitalier Universitaire d'Ambroise Paré, Hainaut, Belgium.
  • Department of Radiology, Centre Hospitalier Universitaire de Tivoli, Hainaut, Belgium.
  • Department of Orthopaedics and Traumatology, Centre Hospitalier Universitaire de Tivoli, Hainaut, Belgium.
  • Department of Orthopaedics and Traumatology, Cliniques Universitaires de Bruxelles - Hôpital Erasme, Hainaut, Belgium.

Zitieren

APA

Jérôme, V., Jacques, H., Esfandiar, C., Xavier, C., Dorothée, F., Harold, J., & René, V. (2023). Could a three-dimensional contralateral meniscus segmentation for allograft or scaffold sizing be possible? A prospective study. International Orthopaedics. https://doi.org/10.1007/s00264-023-05923-6

Vancouver

Jérôme V, Jacques H, Esfandiar C, Xavier C, Dorothée F, Harold J, et al. Could a three-dimensional contralateral meniscus segmentation for allograft or scaffold sizing be possible? A prospective study. International Orthopaedics. 2023. doi:10.1007/s00264-023-05923-6

BibTeX
@article{Jrme2023,
  author = {Jérôme, Valcarenghi and Jacques, Hernigou and Esfandiar, Chahidi and Xavier, Collard and Dorothée, Francotte and Harold, Jennart and René, Verdonk},
  title = {Could a three-dimensional contralateral meniscus segmentation for allograft or scaffold sizing be possible? A prospective study},
  journal = {International Orthopaedics},
  year = {2023},
  doi = {10.1007/s00264-023-05923-6}
}
Kostenlos starten →