When US and MRI disagree: association of pre- high-intensity focused ultrasound imaging discordance with technical, safety, and clinical outcomes in uterine fibroid ablation
Abdominal Radiology · 17.11.2026
DOI: 10.1007/s00261-026-05888-1 ↗Kurz gefasst
Fachartikel in der Zeitschrift Abdominal Radiology, online erschienen am 17.11.2026. Verfasst von Alisa Mohebbi und 4 weiteren Autor:innen. Beteiligte Einrichtung: Tehran University of Medical Sciences, Tehran, Islamic Republic of Iran. Die Arbeit nennt 16 Literaturangaben.
Abstract (Originalsprache)
Purpose
To evaluate the prevalence of pre-procedural US-MRI discordance and its association with Society of Interventional Radiology (SIR)-standardized outcomes in patients undergoing US-guided high-intensity focused ultrasound (HIFU) ablation for symptomatic uterine fibroids. Materials and methods 308 consecutive patients were included. Discordance was defined as mismatch in fibroid type, location, uterine position, or absolute volume percentage difference > 50%. Patients were stratified into concordant ( n = 252) and discordant ( n = 56) groups. Outcomes were assessed according to SIR domains: technical success (non-perfused volume ratio on day-1 contrast-enhanced MRI), technical efficacy (through six procedural surrogates as a whole: energy-efficiency factor, overall treatment time, cumulative sonication time, treatment intensity, average sonication power, and oxytocin dose), adverse events (SIR classification), and favorable short-term procedural outcome.
Results
Discordance occurred in 18.2% of cases. Categorical agreement was high, with Gwet’s AC1 > 0.93, and volume agreement was good, with an intraclass correlation coefficient of 0.773. Day-1 non-perfused volume ratio and technical-success thresholds were comparable between groups. In unadjusted analysis, the energy-efficiency factor was higher after discordant imaging ( p = 0.024) and oxytocin use was shifted toward the 60 IU dose ( p = 0.036). After adjustment, neither association remained significant ( p = 0.191 and 0.228). Adverse-event profiles and the favorable short-term procedural outcome did not differ significantly.
Conclusion
In this study, pre-HIFU US–MRI discordance was not associated with clear differences in technical success, technical efficacy, adverse events, or short-term procedural outcomes. Recognition of discordance may still help inform procedural planning and patient counseling within SIR-standardized frameworks.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Tehran University of Medical Sciences, Tehran, Islamic Republic of Iran.
- Johns Hopkins Medicine, Baltimore, USA.
- Danube Private University, Krems, Austria.
- Urmia University of Medical Sciences, Urmia, Islamic Republic of Iran. mohammadi.a@umsu.ac.ir.
ORCID-Profile: Alisa Mohebbi, Zahra Moradi
Zitieren
APA
Mohebbi, A., Mirza-Aghazadeh-Attari, M., Moradi, Z., Ardakani, A. A., & Mohammadi, A. (2026). When US and MRI disagree: association of pre- high-intensity focused ultrasound imaging discordance with technical, safety, and clinical outcomes in uterine fibroid ablation. Abdominal Radiology. https://doi.org/10.1007/s00261-026-05888-1
Vancouver
Mohebbi A, Mirza-Aghazadeh-Attari M, Moradi Z, Ardakani AA, Mohammadi A. When US and MRI disagree: association of pre- high-intensity focused ultrasound imaging discordance with technical, safety, and clinical outcomes in uterine fibroid ablation. Abdominal Radiology. 2026. doi:10.1007/s00261-026-05888-1
BibTeX
@article{Mohebbi2026,
author = {Mohebbi, Alisa and Mirza-Aghazadeh-Attari, Mohammad and Moradi, Zahra and Ardakani, Ali Abbasian and Mohammadi, Afshin},
title = {When US and MRI disagree: association of pre- high-intensity focused ultrasound imaging discordance with technical, safety, and clinical outcomes in uterine fibroid ablation},
journal = {Abdominal Radiology},
year = {2026},
doi = {10.1007/s00261-026-05888-1}
}
EUVIMED