Decreasing safety events and reconciliation errors in CT imaging
Abdominal Radiology · 20.06.2026 · 51 (12) · 6636-6642
DOI: 10.1007/s00261-026-05625-8 ↗Kurz gefasst
Fachartikel in der Zeitschrift Abdominal Radiology, online erschienen am 20.06.2026. Verfasst von Vivek Batra und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Imaging, University of Rochester Medical Center, Rochester, USA. vivek_batra@urmc.rochester.edu. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Radiology Information Systems, Quality Improvement, Patient Safety. Die Arbeit nennt 17 Literaturangaben.
Abstract (Originalsprache)
Objective
Imaging reconciliation errors within Picture Archiving and Communication Systems (PACS) can lead to adverse patient outcomes, unnecessary procedures, and delayed care. Historically, our institution averaged 400 safety-related events annually, including high-priority errors such as images linked to the wrong patient, incomplete image transmissions, and images stored in incorrect PACS folders. Our quality improvement (QI) team aimed to decrease high-priority reconciliation event rates in Computed Tomography (CT) from a baseline of 4.75 events per 1,000 exams to 1.9 events per 1,000 exams by June 2024.
Methods
Conducted at a large academic medical center, this continuous QI initiative deployed a bundled intervention consisting of workflow redesign and mandatory forms, technological safeguards via barcode scanners, and a cultural shift driven by data transparency and targeted coaching. Data was analyzed using statistical process control (SPC) charts.
Results
Between July 2, 2023, and February 23, 2025, the overall rate of reconciliation events decreased to 0.1%. Potentially serious safety errors dropped to fewer than 100 per year, and the average time elapsed between reconciliation events increased by 493%. The operational burden of manual reconciliation was reduced by an estimated 150 h annually.
Discussion
A sustained reduction in errors was achieved through a comprehensive system redesign. Pairing standardized workflows and mandatory documentation with high-reliability technology, data transparency, and routine feedback proved highly effective at establishing a scalable reduction in imaging errors.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Imaging, University of Rochester Medical Center, Rochester, USA. vivek_batra@urmc.rochester.edu.
- Department of Imaging, University of Rochester Medical Center, Rochester, USA.
Zitieren
APA
Batra, V., Panter, E., Conley, A., Murray, T., & Wandtke, B. (2026). Decreasing safety events and reconciliation errors in CT imaging. Abdominal Radiology, 51(12), 6636-6642. https://doi.org/10.1007/s00261-026-05625-8
Vancouver
Batra V, Panter E, Conley A, Murray T, Wandtke B. Decreasing safety events and reconciliation errors in CT imaging. Abdominal Radiology. 2026;51(12):6636-6642. doi:10.1007/s00261-026-05625-8
BibTeX
@article{Batra2026,
author = {Batra, Vivek and Panter, Erin and Conley, Ashley and Murray, Thomas and Wandtke, Ben},
title = {Decreasing safety events and reconciliation errors in CT imaging},
journal = {Abdominal Radiology},
year = {2026},
volume = {51},
number = {12},
pages = {6636--6642},
doi = {10.1007/s00261-026-05625-8}
}
EUVIMED