Quantitative and qualitative evaluation of pancreatic cancer on photon-counting detector CT and dual-energy CT using standard reference images
Abdominal Radiology · 03.03.2026 · 51 (9) · 4465-4474
DOI: 10.1007/s00261-026-05444-x ↗Kurz gefasst
Fachartikel in der Zeitschrift Abdominal Radiology, online erschienen am 03.03.2026. Verfasst von Takahito Niiyama und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, University of Toyama, Toyama, Japan. Hauptthemen laut MEDLINE: Pancreatic Neoplasms, Tomography, X-Ray Computed, Radiography, Dual-Energy Scanned Projection. Die Arbeit nennt 36 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: To compare the depiction performance of photon-counting detector CT (PCD-CT) and dual-energy CT (DE-CT) quantitatively and qualitatively for pancreatic cancer under reference conditions equivalent to 120 kVp, used in clinical practice. METHOD: For this retrospective single-center study, 124 patients with pathologically proven pancreatic cancer who had undergone initial dynamic contrast-enhanced upper abdominal CT between January 2023 and October 2024 were included (PCD-CT: n = 62; DE-CT: n = 62). Reference images were 70 keV virtual monoenergetic images for PCD-CT and 80/Sn150 kVp linearly blended images for DE-CT. The tumor-to-pancreas ratio (TPR) and contrast-to-noise ratio (CNR) were calculated in the pancreatic and equilibrium phases. After two radiologists rated tumor visibility independently using a five-point scale, the mean visibility score was analyzed. Group differences were assessed using Welch's t test and linear regression adjusted for age, body mass index (BMI), tumor size, and tumor location. A predefined subgroup analysis was conducted for tumors ≤ 20 mm (pancreatic phase). RESULT: In the equilibrium phase, the visibility score was higher with PCD-CT than with DE-CT (3.065 vs. 2.548; p < 0.001) and remained significant after adjustment (β = +0.305; p = 0.032). TPR and CNR were similar in both phases (pancreatic: TPR 0.495 vs. 0.537, p = 0.088; CNR 13.789 vs. 12.231, p = 0.246; equilibrium: TPR 1.027 vs. 1.017, p = 0.868; CNR 0.901 vs. 0.110, p = 0.597), as was pancreatic-phase visibility (4.250 vs. 4.065; p = 0.136). Results for tumors ≤ 20 mm were consistent with the main analysis. CONCLUSION: Under 120 kVp-equivalent conditions, PCD-CT and DE-CT showed comparable quantitative performance for pancreatic cancer, whereas PCD-CT provided superior subjective tumor visibility in the equilibrium phase, suggesting improved visual detectability without loss of quantitative image quality.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Radiology, University of Toyama, Toyama, Japan.
- Department of Radiology, Toyama University Hospital, Toyama, Japan.
- Department of Radiology, University of Toyama, Toyama, Japan. akido.toyama@gmail.com.
Zitieren
APA
Niiyama, T., Naruto, N., Nishikawa, K., Yamamoto, K., Kawahara, Y., Doai, M., Kido, A., & Noguchi, K. (2026). Quantitative and qualitative evaluation of pancreatic cancer on photon-counting detector CT and dual-energy CT using standard reference images. Abdominal Radiology, 51(9), 4465-4474. https://doi.org/10.1007/s00261-026-05444-x
Vancouver
Niiyama T, Naruto N, Nishikawa K, Yamamoto K, Kawahara Y, Doai M, et al. Quantitative and qualitative evaluation of pancreatic cancer on photon-counting detector CT and dual-energy CT using standard reference images. Abdominal Radiology. 2026;51(9):4465-4474. doi:10.1007/s00261-026-05444-x
BibTeX
@article{Niiyama2026,
author = {Niiyama, Takahito and Naruto, Norihito and Nishikawa, Kazuma and Yamamoto, Ken and Kawahara, Yasuhiro and Doai, Mariko and Kido, Aki and Noguchi, Kyo},
title = {Quantitative and qualitative evaluation of pancreatic cancer on photon-counting detector CT and dual-energy CT using standard reference images},
journal = {Abdominal Radiology},
year = {2026},
volume = {51},
number = {9},
pages = {4465--4474},
doi = {10.1007/s00261-026-05444-x}
}