Agreement between single and multiple ROI strategies for hepatic T1 and ECV mapping in tetralogy of Fallot and Fontan circulation

Adriana Macintyre Innocenzi, Fernanda Padrão Fernandes, José Carlos Pizzolante Secco, Igor Costa Costermani, José Lucas Rebelo, Aline Silva de Medeiros, Daniella Braz Parente, Renata Mello Perez, Ronir Raggio Luiz, Gabriel Cordeiro Camargo, Renata Moll-Bernardes, Mariana Póvoa-Corrêa

Abdominal Radiology · 09.03.2026 · 51 (9) · 4421-4430

DOI: 10.1007/s00261-026-05441-0 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Abdominal Radiology, online erschienen am 09.03.2026. Verfasst von Adriana Macintyre Innocenzi und 11 weiteren Autor:innen. Beteiligte Einrichtung: D'Or Institute for Research and Education, Rio de Janeiro, Brazil. adrianaminnocenzi@gmail.com. Hauptthemen laut MEDLINE: Tetralogy of Fallot, Fontan Procedure, Magnetic Resonance Imaging. Die Arbeit nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Faculdade Idor De Ciências Médicas.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Native T1 and extracellular volume (ECV) mapping have emerged as promising tools for noninvasive assessment of hepatic congestion and fibrosis; however, optimal strategies for region-of-interest (ROI) selection remain uncertain. The aim was to evaluate the level of agreement between two methods for quantifying hepatic native T1 and ECV: single wide ROI versus multiple small ROIs, in patients with repaired tetralogy of Fallot (TOF) and Fontan circulation.

Methods

This agreement study prospectively enrolled outpatients with repaired TOF or Fontan circulation between 2022 and 2025. All participants underwent hepatic evaluation using a cardiac Magnetic Resonance Imaging (MRI) protocol on a 3.0-T scanner. Native and post-contrast T1 mapping were acquired using Modified Look-Locker Inversion Recovery (MOLLI) sequences. Hepatic T1 and ECV were measured using (1) one wide ROI avoiding vascular structures and (2) three small circular ROIs placed in distinct parenchymal regions. Agreement was assessed using intraclass correlation coefficients (ICC) and survival-agreement plots.

Results

A total of 61 patients was included (31 with TOF; 30 with Fontan circulation). Agreement between single-ROI and multiple-ROI strategies was excellent in TOF patients for both native T1 and ECV (ICC = 0.98), and good in patients with Fontan circulation for both parameters (ICC = 0.79). Survival-agreement analysis demonstrated that in TOF patients, all measurements differed by less than 80 ms for native T1 and less than 5% for ECV. In Fontan patients, 86% of measurements showed differences < 80 ms for native T1 and < 5% for ECV, reflecting greater hepatic heterogeneity while preserving overall concordance between ROI strategies.

Conclusions

Hepatic native T1 and ECV measurements showed excellent agreement between single-wide and multiple-small ROI strategies in repaired TOF, supporting interchangeable use for longitudinal follow-up. In Fontan patients, concordance between methods was also good, as demonstrated by both ICC and survival-agreement analyses, indicating that either strategy remains feasible; nonetheless, the greater hepatic heterogeneity in this population warrants some caution when comparing measurements obtained with different ROI approaches.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tetralogy of FallotFontan ProcedureMagnetic Resonance ImagingHumansFemaleMaleProspective StudiesChildAdolescentLiverContrast MediaChild, PreschoolAdult

Stichwörter der Autor:innen

FibrosisFontan procedureLiver diseasesMagnetic resonance imagingTetralogy of fallot

Substanzen

Contrast Media

Autor:innen und Institutionen

  • D'Or Institute for Research and Education, Rio de Janeiro, Brazil. adrianaminnocenzi@gmail.com.
  • Instituto Nacional de Cardiologia, Rio de Janeiro, Brazil. adrianaminnocenzi@gmail.com.
  • D'Or Institute for Research and Education, Rio de Janeiro, Brazil.
  • Instituto Nacional de Cardiologia, Rio de Janeiro, Brazil.
  • Federal University of Rio de Janeiro, Rio de Janeiro, Brazil.
  • D'Or Institute for Research and Education, Rio de Janeiro, Brazil. renata.moll@idor.org.

Förderung

  • Faculdade Idor De Ciências Médicas

Zitieren

APA

Innocenzi, A. M., Fernandes, F. P., Secco, J. C. P., Costermani, I. C., Rebelo, J. L., Medeiros, A. S., Parente, D. B., Perez, R. M., Luiz, R. R., Camargo, G. C., Moll-Bernardes, R., & Póvoa-Corrêa, M. (2026). Agreement between single and multiple ROI strategies for hepatic T1 and ECV mapping in tetralogy of Fallot and Fontan circulation. Abdominal Radiology, 51(9), 4421-4430. https://doi.org/10.1007/s00261-026-05441-0

Vancouver

Innocenzi AM, Fernandes FP, Secco JCP, Costermani IC, Rebelo JL, Medeiros AS, et al. Agreement between single and multiple ROI strategies for hepatic T1 and ECV mapping in tetralogy of Fallot and Fontan circulation. Abdominal Radiology. 2026;51(9):4421-4430. doi:10.1007/s00261-026-05441-0

BibTeX
@article{Innocenzi2026,
  author = {Innocenzi, Adriana Macintyre and Fernandes, Fernanda Padrão and Secco, José Carlos Pizzolante and Costermani, Igor Costa and Rebelo, José Lucas and Medeiros, Aline Silva de and Parente, Daniella Braz and Perez, Renata Mello and Luiz, Ronir Raggio and Camargo, Gabriel Cordeiro and Moll-Bernardes, Renata and Póvoa-Corrêa, Mariana},
  title = {Agreement between single and multiple ROI strategies for hepatic T1 and ECV mapping in tetralogy of Fallot and Fontan circulation},
  journal = {Abdominal Radiology},
  year = {2026},
  volume = {51},
  number = {9},
  pages = {4421--4430},
  doi = {10.1007/s00261-026-05441-0}
}
Kostenlos starten →