EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Agreement of axial T2-MRI versus Contrast-Enhanced CT for solid renal mass active surveillance

Bendik Breen, Khalefa Alghofaily, Heidi Søgaard Christensen, Jens Brøndum Frøkjær, Ole Graumann, Mats Kleivane, Lise Medrud, Rasa Mikalone, Stig Müller, Gintare Naujokaite, Anne Negård, Ivar Mjåland Salte und 2 weitere

Abdominal Radiology · 2026

DOI: 10.1007/s00261-026-05376-6 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Abdominal Radiology, 2026. Verfasst von Bendik Breen und 13 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Akershus University Hospital, Lillestrøm, Norway. Hauptthemen laut MEDLINE: Contrast Media, Kidney Neoplasms, Tomography, X-Ray Computed, Magnetic Resonance Imaging. Die Arbeit nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Akershus University Hospital.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Active surveillance (AS) of small renal masses (SRMs) typically relies on contrast-enhanced CT for serial size measurement. Non-contrast (NC) MRI protocols may provide an alternative. To assess the agreement of maximum axial tumor diameter and tumor nearness between NC MRI and contrast-enhanced CT for SRM surveillance, and to compare diagnostic confidence in tumor delineation across modalities.

Methods

We retrospectively identified 50 patients (mean age, 62.9 years; 44% women) who underwent both contrast-enhanced CT and axial T2-weighted MRI within 3 months as part of AS protocol. Nine radiologists from five hospitals independently assessed maximum tumor diameter (axial plane) and tumor nearness to the collecting system (TN, three-tier scale) and subjectively graded their diagnostic confidence in delineating the tumor contour (DC, 5-point scale) in 50 CT and MRI scans across four randomized reading sessions. Observer agreement for diameter assessment was quantified using the limits of agreement with the mean (LOAM), whereas TN and DC were analyzed using Gwet’s AC2.

Results

Mean tumor diameters were 19.9 mm for CT and 19.5 mm for MRI (mean difference, 0.4 mm; p = 0.051). Reproducibility LOAMs were ± 2.9 [2.7–3.2] mm (CT) and ± 3.1 [2.9–3.4] mm (MRI), with overlapping confidence intervals. TN ratings and agreement were similar for CT and MRI ( p = 0.61; p = 0.86, respectively), whereas DC ratings were higher and interobserver agreement was better for CT ( p < 0.001 and p = 0.009, respectively)..

Conclusion

NC axial T2-weighted MRI demonstrated tumor diameter agreement comparable to contrast-enhanced CT, along with comparable TN ratings and agreement, whereas CT yielded higher DC and better interobserver agreement for DC.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Contrast MediaKidney NeoplasmsTomography, X-Ray ComputedMagnetic Resonance ImagingWatchful WaitingHumansFemaleMiddle AgedRetrospective StudiesMaleReproducibility of ResultsAged

Stichwörter der Autor:innen

Active surveillanceContrast-enhanced CTNon-contrast MRISmall renal massesTumor diameter measurement

Substanzen

Contrast Media

Autor:innen und Institutionen

  • Department of Radiology, Akershus University Hospital, Lillestrøm, Norway.
  • Institute of Clinical Medicine, University of Oslo, Oslo, Norway.
  • Department of Radiology, Ottawa Hospital, Ottawa, Canada.
  • Department of Radiology, College of Medicine, Qassim University, Qassim, Saudi Arabia.
  • Department of Clinical Medicine, Aalborg University, Aalborg, Denmark.
  • Department of Radiology, Aalborg University Hospital, Aalborg, Denmark.

Förderung

  • Akershus University Hospital

Zitieren

APA

Breen, B., Alghofaily, K., Christensen, H. S., Frøkjær, J. B., Graumann, O., Kleivane, M., Medrud, L., Mikalone, R., Müller, S., Naujokaite, G., Negård, A., Salte, I. M., Schieda, N., & Borgbjerg, J. (2026). Agreement of axial T2-MRI versus Contrast-Enhanced CT for solid renal mass active surveillance. Abdominal Radiology. https://doi.org/10.1007/s00261-026-05376-6

Vancouver

Breen B, Alghofaily K, Christensen HS, Frøkjær JB, Graumann O, Kleivane M, et al. Agreement of axial T2-MRI versus Contrast-Enhanced CT for solid renal mass active surveillance. Abdominal Radiology. 2026. doi:10.1007/s00261-026-05376-6

BibTeX
@article{Breen2026,
  author = {Breen, Bendik and Alghofaily, Khalefa and Christensen, Heidi Søgaard and Frøkjær, Jens Brøndum and Graumann, Ole and Kleivane, Mats and Medrud, Lise and Mikalone, Rasa and Müller, Stig and Naujokaite, Gintare and Negård, Anne and Salte, Ivar Mjåland and Schieda, Nicola and Borgbjerg, Jens},
  title = {Agreement of axial T2-MRI versus Contrast-Enhanced CT for solid renal mass active surveillance},
  journal = {Abdominal Radiology},
  year = {2026},
  doi = {10.1007/s00261-026-05376-6}
}
Kostenlos starten →