EUVIMEDEUVIMED entdecken
Crossref

Inter-software agreement in abdominal computed diffusion-weighted imaging: apparent diffusion coefficient and image quality assessment

Tsukasa Yoshida, Atsushi Urikura, Kazuaki Nakashima, Ippei Kawashima, Masahiro Endo

Abdominal Radiology · 2025

DOI: 10.1007/s00261-025-05198-y ↗

Kurz gefasst

Fachartikel in der Zeitschrift Abdominal Radiology, 2025. Verfasst von Tsukasa Yoshida und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic Radiology, Shizuoka Cancer Center, Shizuoka, Japan. ts.yoshida@scchr.jp. Hauptthemen laut MEDLINE: Diffusion Magnetic Resonance Imaging, Software, Abdomen, Image Interpretation, Computer-Assisted. Die Arbeit nennt 33 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To investigate the agreement in apparent diffusion coefficient (ADC) values and the image quality of abdominal computed diffusion-weighted imaging (cDWI) generated by two software programs. METHODS: This retrospective study included 154 patients (64 males, 90 females; mean age: 70.1 ± 10.7 years) who underwent abdominal diffusion-weighted imaging (DWI) between November 2023 and October 2024. DWI was acquired with a b = 0 and 1000 s/mm2 using a 3.0T scanner. cDWIs with b 1500 and 2000 were generated by a scanner console software and a commercially available software program. The ADC and signal-to-noise ratio (SNR) were measured in normal tissues. The contrast-to-noise ratio (CNR) of normal tissues relative to the paraspinal muscle was also measured. Agreement and reliability of ADC value were assessed using Bland-Altman analysis and intraclass correlation coefficients (ICC), respectively. SNR and CNR were compared using paired t-tests. RESULTS: ADC bias and limits of agreement ranged from - 0.2 to 0.7% and 0.3-2.1%, respectively. ICCs for ADC values ranged within 0.991 and 1.000 (p < 0.05) for all tissues. Significant SNR differences were observed in b1500 (liver, spleen, kidney) and b2000 (liver, bile). Significant CNR differences were noted in b1500 (liver, pancreas, kidney) and b2000 (excluding spleen). CONCLUSION: There is strong agreement and high reliability in ADC values between the two software programs. Although significant differences in SNR and CNR were observed, their clinical impact appears minimal. These findings indicate that the ADC values and image quality of cDWI are consistent between the two software programs.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Diffusion Magnetic Resonance ImagingSoftwareAbdomenImage Interpretation, Computer-AssistedHumansFemaleMaleRetrospective StudiesAgedReproducibility of ResultsSignal-To-Noise RatioMiddle AgedAged, 80 and over

Stichwörter der Autor:innen

Apparent diffusion coefficientContrast-to-noise ratioDiffusion-weighted magnetic resonance imagingMagnetic resonance imagingSignal-to-noise ratio

Autor:innen und Institutionen

  • Department of Diagnostic Radiology, Shizuoka Cancer Center, Shizuoka, Japan. ts.yoshida@scchr.jp.
  • Graduate School of Health Sciences, Ibaraki Prefectural University of Health Sciences, Ibaraki, Japan.
  • Department of Diagnostic Radiology, National Cancer Center Hospital, Tokyo, Japan.
  • Department of Diagnostic Radiology, Shizuoka Cancer Center, Shizuoka, Japan.

Zitieren

APA

Yoshida, T., Urikura, A., Nakashima, K., Kawashima, I., & Endo, M. (2025). Inter-software agreement in abdominal computed diffusion-weighted imaging: apparent diffusion coefficient and image quality assessment. Abdominal Radiology. https://doi.org/10.1007/s00261-025-05198-y

Vancouver

Yoshida T, Urikura A, Nakashima K, Kawashima I, Endo M. Inter-software agreement in abdominal computed diffusion-weighted imaging: apparent diffusion coefficient and image quality assessment. Abdominal Radiology. 2025. doi:10.1007/s00261-025-05198-y

BibTeX
@article{Yoshida2025,
  author = {Yoshida, Tsukasa and Urikura, Atsushi and Nakashima, Kazuaki and Kawashima, Ippei and Endo, Masahiro},
  title = {Inter-software agreement in abdominal computed diffusion-weighted imaging: apparent diffusion coefficient and image quality assessment},
  journal = {Abdominal Radiology},
  year = {2025},
  doi = {10.1007/s00261-025-05198-y}
}
Kostenlos starten →