The evaluation of non-contrast MRA using a modified balanced steady state free precession technique in the follow-up of renal artery aneurysm after embolotherapy
Abdominal Radiology · 2025
DOI: 10.1007/s00261-025-05193-3 ↗Kurz gefasst
Fachartikel in der Zeitschrift Abdominal Radiology, 2025. Verfasst von Pengyun Zhang und 5 weiteren Autor:innen. Beteiligte Einrichtung: Peking University First Hospital, Beijing, China. Hauptthemen laut MEDLINE: Embolization, Therapeutic, Renal Artery, Magnetic Resonance Angiography, Aneurysm. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 28 Literaturangaben. Gefördert von: Scientific Research Seed Fund of Peking University First Hospital.
Abstract (Originalsprache)
PURPOSE: To evaluate the feasibility and clinical utility of non-contrast magnetic resonance angiography (NC-MRA) using a modified balanced steady-state free precession (b-SSFP) technique combined with arterial spin labeling (ASL) for post-embolotherapy follow-up of renal artery aneurysms (RAAs), with digital subtraction angiography (DSA) as the reference standard. METHOD: A total of 57 patients with RAAs underwent embolotherapy between June 2013 and July 2024. Among them, 15 RAAs from 14 patients underwent post-embolization surveillance with the NC-MRA and DSA. NC-MRA was performed at 12 months after coil embolization, followed by DSA. On NC-MRA images, complete occlusion is indicated by the absence of high signal within the aneurysm, whereas on DSA images, complete occlusion is defined as the absence of contrast enhancement within the aneurysm. We compare the NC-MRA and DSA results for each aneurysm during follow-up. RESULTS: Of the 15 aneurysms, 12 achieved complete occlusion and 3 exhibited incomplete occlusion. There was no aneurysmal growth, and no adverse events such as rupture or renal infarction occurred. We acquired 15 groups of follow-up MRA and DSA images, and the results were in perfect concordance. CONCLUSION: The NC-MRA using the modified b-SSFP combined with ASL shows good agreement with DSA in assessing recanalization of RAAs after embolotherapy and may serve as a reliable, non-invasive follow-up modality.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Peking University First Hospital, Beijing, China.
- Peking University First Hospital, Beijing, China. ygglww@sina.com.
Förderung
- Scientific Research Seed Fund of Peking University First Hospital
Zitieren
APA
Zhang, P., Yan, Z., Li, P., Zhang, B., Niu, G., & Yang, M. (2025). The evaluation of non-contrast MRA using a modified balanced steady state free precession technique in the follow-up of renal artery aneurysm after embolotherapy. Abdominal Radiology. https://doi.org/10.1007/s00261-025-05193-3
Vancouver
Zhang P, Yan Z, Li P, Zhang B, Niu G, Yang M. The evaluation of non-contrast MRA using a modified balanced steady state free precession technique in the follow-up of renal artery aneurysm after embolotherapy. Abdominal Radiology. 2025. doi:10.1007/s00261-025-05193-3
BibTeX
@article{Zhang2025,
author = {Zhang, Pengyun and Yan, Ziguang and Li, Pengyu and Zhang, Bihui and Niu, Guochen and Yang, Min},
title = {The evaluation of non-contrast MRA using a modified balanced steady state free precession technique in the follow-up of renal artery aneurysm after embolotherapy},
journal = {Abdominal Radiology},
year = {2025},
doi = {10.1007/s00261-025-05193-3}
}
EUVIMED