Low-keV virtual monoenergetic images with rapid kilovoltage-switching DECT for differentiating complicated from uncomplicated appendicitis in adults
Abdominal Radiology · 2025
DOI: 10.1007/s00261-025-05124-2 ↗Kurz gefasst
Fachartikel in der Zeitschrift Abdominal Radiology, 2025. Verfasst von Dhanawin Wongsaengchan und 5 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand. Hauptthemen laut MEDLINE: Appendicitis, Tomography, X-Ray Computed, Radiography, Dual-Energy Scanned Projection. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Mahidol University.
Abstract (Originalsprache)
Objectives
Low-keV virtual monoenergetic images on dual-energy CT (DECT) enhance iodine attenuation in inflamed appendiceal walls, but the role in differentiating complicated from uncomplicated appendicitis remains unclear. This is particularly relevant given the shift toward nonoperative management of uncomplicated appendicitis.
Methods
Consecutive adult patients with pathologically confirmed acute appendicitis who underwent preoperative rapid-kVP-switching DECT and appendectomy within 24 h were retrospectively included. Two radiologists reviewed DECT images, including a finding of appendiceal wall enhancement defects, using three series: 50-keV monoenergetic, 120-kVp-equivalent, and combined series, with discrepancies resolved by a third radiologist. Diagnostic performance of three series for differentiating complicated from uncomplicated appendicitis was assessed. Detection rates of appendiceal wall enhancement defects and radiologist confidence among three series were compared.
Results
Among 155 patients (50 men, mean age 47.4±19.0 years), 59 had complicated appendicitis. The combined 50-keV/120-kVp-equivalent series provided balanced sensitivity (83.1%) and specificity (86.5%), with an accuracy of 85.2% in differentiating uncomplicated and complicated appendicitis. Although 50-keV images revealed the most wall enhancement defects (48/122; 39.3%), radiologists’ confidence was significantly higher using the combined series (91.8% vs. 72.1%, p < 0.001).
Conclusions
Low-keV virtual monoenergetic DECT, when combined with 120-kVP-equivalent images, improved the detection of appendiceal wall enhancement defects and increased radiologist confidence in differentiating complicated from uncomplicated appendicitis in adult patients with acute appendicitis.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand.
- Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand. rathachai@gmail.com.
Förderung
- Mahidol University
Zitieren
APA
Wongsaengchan, D., Chatpuwaphat, J., Thiravit, S., Tongsai, S., Noppakunsomboon, N., & Kaewlai, R. (2025). Low-keV virtual monoenergetic images with rapid kilovoltage-switching DECT for differentiating complicated from uncomplicated appendicitis in adults. Abdominal Radiology. https://doi.org/10.1007/s00261-025-05124-2
Vancouver
Wongsaengchan D, Chatpuwaphat J, Thiravit S, Tongsai S, Noppakunsomboon N, Kaewlai R. Low-keV virtual monoenergetic images with rapid kilovoltage-switching DECT for differentiating complicated from uncomplicated appendicitis in adults. Abdominal Radiology. 2025. doi:10.1007/s00261-025-05124-2
BibTeX
@article{Wongsaengchan2025,
author = {Wongsaengchan, Dhanawin and Chatpuwaphat, Jitti and Thiravit, Shanigarn and Tongsai, Sasima and Noppakunsomboon, Napakadol and Kaewlai, Rathachai},
title = {Low-keV virtual monoenergetic images with rapid kilovoltage-switching DECT for differentiating complicated from uncomplicated appendicitis in adults},
journal = {Abdominal Radiology},
year = {2025},
doi = {10.1007/s00261-025-05124-2}
}
EUVIMED