EUVIMEDEUVIMED entdecken
Crossref

Effectiveness of T2-weighted and contrast-enhanced T1-weighted multivane sequences in the preoperative evaluation of uterine endometrial cancer

Tomohiro Ando, Hiroki Kato, Takahide Maeda, Takuya Seko, Tatsuro Furui, Masanori Isobe, Kimihiro Kajita, Masaya Kawaguchi, Yoshifumi Noda, Abdelazim Elsayed Elhelaly, Hirohiko Imai, Masayuki Matsuo

Abdominal Radiology · 2025

DOI: 10.1007/s00261-025-05107-3 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Abdominal Radiology, 2025. Verfasst von Tomohiro Ando und 11 weiteren Autor:innen. Beteiligte Einrichtung: Gifu University, Gifu City, Japan. ando.tomohiro.y6@f.gifu-u.ac.jp. Hauptthemen laut MEDLINE: Endometrial Neoplasms, Magnetic Resonance Imaging, Preoperative Care, Image Enhancement. Die Arbeit nennt 19 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: The purpose of this study was to evaluate the clinical effectiveness of MultiVane (MV) sequence, which is a motion correction technique using rotating blades, for patients with uterine endometrial cancer. MATERIALS AND METHODS: This study enrolled 42 patients with histopathologically confirmed uterine endometrial cancer, who underwent preoperative MRI including sagittal T2-weighted images (T2WI) and contrast-enhanced T1-weighted images (CE-T1WI) acquired using both turbo spin-echo (TSE) and MV sequences with approximately matched acquisition times. Two experienced radiologists independently evaluated all sagittal images. First, the readers assessed the degree of motion artifacts and measured the signal intensity of the tumor and myometrium to calculate the signal-to-noise ratio (SNR) and tumor-to-myometrium contrast ratio (CR). Second, the readers assessed the depth of myometrial invasion on sagittal T2WI and CE-T1WI acquired using TSE and MV sequences. Image quality and diagnostic performance for assessing myometrial invasion were compared between TSE and MV sequences. RESULTS: Motion artifacts were significantly improved on MV sequence than on TSE sequence (p 0.05). Sensitivities, specificities, accuracies, and area under the curve for the diagnosis of myometrial invasion were slightly increased on MV sequence than on TSE sequence, but these differences were not statistically significant (p > 0.05). CONCLUSION: MV sequence contributes to the improvement of motion artifacts in the female pelvis without degrading SNR and CR of endometrial cancer and myometrium compared to TSE sequence. MV sequence did not significantly improve the diagnostic performance for assessing myometrial invasion in endometrial cancer, possibly due to the limited imaging plane and small sample size.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Endometrial NeoplasmsMagnetic Resonance ImagingPreoperative CareImage EnhancementHumansFemaleContrast MediaMiddle AgedAgedArtifactsAdultRetrospective StudiesAged, 80 and overNeoplasm InvasivenessSignal-To-Noise Ratio

Stichwörter der Autor:innen

Motion artifactMultiVaneMyometrial invasionUterine endometrial cancer

Substanzen

Contrast Media

Autor:innen und Institutionen

  • Gifu University, Gifu City, Japan. ando.tomohiro.y6@f.gifu-u.ac.jp.
  • Gifu University, Gifu City, Japan.
  • Massachusetts General Hospital, Boston, United States.

Zitieren

APA

Ando, T., Kato, H., Maeda, T., Seko, T., Furui, T., Isobe, M., Kajita, K., Kawaguchi, M., Noda, Y., Elhelaly, A. E., Imai, H., & Matsuo, M. (2025). Effectiveness of T2-weighted and contrast-enhanced T1-weighted multivane sequences in the preoperative evaluation of uterine endometrial cancer. Abdominal Radiology. https://doi.org/10.1007/s00261-025-05107-3

Vancouver

Ando T, Kato H, Maeda T, Seko T, Furui T, Isobe M, et al. Effectiveness of T2-weighted and contrast-enhanced T1-weighted multivane sequences in the preoperative evaluation of uterine endometrial cancer. Abdominal Radiology. 2025. doi:10.1007/s00261-025-05107-3

BibTeX
@article{Ando2025,
  author = {Ando, Tomohiro and Kato, Hiroki and Maeda, Takahide and Seko, Takuya and Furui, Tatsuro and Isobe, Masanori and Kajita, Kimihiro and Kawaguchi, Masaya and Noda, Yoshifumi and Elhelaly, Abdelazim Elsayed and Imai, Hirohiko and Matsuo, Masayuki},
  title = {Effectiveness of T2-weighted and contrast-enhanced T1-weighted multivane sequences in the preoperative evaluation of uterine endometrial cancer},
  journal = {Abdominal Radiology},
  year = {2025},
  doi = {10.1007/s00261-025-05107-3}
}
Kostenlos starten →