Balloon assisted gastrostomy tube placement
Abdominal Radiology · 2025
DOI: 10.1007/s00261-025-04962-4 ↗Kurz gefasst
Fachartikel in der Zeitschrift Abdominal Radiology, 2025. Verfasst von Norbert Kuc und 4 weiteren Autor:innen. Beteiligte Einrichtung: Montefiore Medical Center, The Bronx, USA. nkuc@montefiore.org. Hauptthemen laut MEDLINE: Gastrostomy, Radiography, Interventional. Die Arbeit nennt 10 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
PURPOSE: To compare the safety and efficacy of balloon-assisted gastrostomy (BAG) placement to the conventional serial dilation technique. METHODS: This study is an IRB-approved retrospective review of all percutaneous gastrostomy tubes placed by an interventional radiology department at a single institution between 2012 and 2021. There were 476 patients identified (average age 63, 44% female): 385 in the serial dilation group and 91 in the balloon assisted gastrostomy (BAG) group. Patient demographic, procedure, and radiological data were reviewed in the medical record to determine procedure success, procedure/fluoroscopy time, and tube failures. Gastrostomy tube failure was defined as tube leak, clogging, or dislodgement. Adverse events were classified as per Society of Interventional Radiology guidelines. Statistical analysis was performed using Fisher’s exact test, student’s t-test, and Mann-Whitney U-test as appropriate. RESULTS: Gastrostomy tubes were successfully placed in 97.7% (377/385) of patients undergoing the serial dilation technique and 100% (91/91) of patients undergoing the BAG placement technique. BAG tube placement was associated with a 2.5 min decrease (47%) in average fluoroscopy time ( p = 0.0002, CI: 3.76 to 1.20). Total procedure time was reduced by an average of 17.2 min (22%) ( p = 0.0006, CI: 26.9 to 7.4). BAG was also associated with an 11% reduction in all cause gastrostomy tube failure ( p = 0.0399). There were no statistically significant differences in the adverse event rates or median days to tube failure. Material costs were $178.32 higher in the BAG group. CONCLUSION: BAG catheter placement can be performed safely and effectively, and is associated with reduced fluoroscopy time, procedure time, and overall failure rate compared to the serial dilation technique.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Montefiore Medical Center, The Bronx, USA. nkuc@montefiore.org.
- Albert Einstein College of Medicine, The Bronx, USA. nkuc@montefiore.org.
- Albert Einstein College of Medicine, The Bronx, USA.
- Columbia University Irving Medical Center, New York, USA.
- St. John's Riverside Hospital, Yonkers, USA.
- Montefiore Medical Center, The Bronx, USA.
Zitieren
APA
Kuc, N., Felman, A., Small, I., Cynamon, J., & Gohari, A. (2025). Balloon assisted gastrostomy tube placement. Abdominal Radiology. https://doi.org/10.1007/s00261-025-04962-4
Vancouver
Kuc N, Felman A, Small I, Cynamon J, Gohari A. Balloon assisted gastrostomy tube placement. Abdominal Radiology. 2025. doi:10.1007/s00261-025-04962-4
BibTeX
@article{Kuc2025,
author = {Kuc, Norbert and Felman, Ariel and Small, Ilan and Cynamon, Jacob and Gohari, Arash},
title = {Balloon assisted gastrostomy tube placement},
journal = {Abdominal Radiology},
year = {2025},
doi = {10.1007/s00261-025-04962-4}
}
EUVIMED