EUVIMEDEUVIMED entdecken
Vergleichsstudie

Deep learning reconstruction of diffusion-weighted imaging with single-shot echo-planar imaging in endometrial cancer: a comparison with multi-shot echo-planar imaging

Taewoo Heo, Nam Kyung Lee, Suk Kim, Seung Baek Hong, Dong Soo Suh, Jin You Kim, Ji Won Lee, Tae Un Kim

Abdominal Radiology · 2025

DOI: 10.1007/s00261-025-04955-3 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Abdominal Radiology, 2025. Verfasst von Taewoo Heo und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, and Biomedical Research Institute, Pusan National University Hospital, Pusan National University School of Medicine, Busan, …. Hauptthemen laut MEDLINE: Endometrial Neoplasms, Echo-Planar Imaging, Diffusion Magnetic Resonance Imaging, Deep Learning. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 42 Literaturangaben. Gefördert von: clinical research grant from Pusan National University Hospital in 2024.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To evaluate the efficacy of deep learning reconstruction (DLR) in diffusion-weighted imaging (DWI) with single-shot echo-planar imaging (SSEPI) for endometrial cancer, compared to multiplexed sensitivity-encoding (MUSE) DWI. METHODS: We retrospectively reviewed 31 women with surgically confirmed endometrial cancer who underwent preoperative pelvic magnetic resonance imaging (MRI) including DWI. Qualitative analysis including overall image quality, susceptibility artifacts, sharpness of the uterine edge, and lesion conspicuity were compared among conventional SSEPI (SSEPI-C), SSEPI with DLR (SSEPI-DL), and MUSE using the Friedman's test. Quantitative analysis including the apparent diffusion coefficient (ADC) values, noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were also compared among three DWI sequences using the Friedman's test. In addition, the diagnostic accuracy for deep myometrial invasion was compared to three DWI sequences using Cochran's Q test. RESULTS: The scores of overall image quality, sharpness of the uterine edge, and lesion conspicuity in SSEPI-DL were higher than SSEPI-C (p 0.05). Noise in SSEPI-DL was lower than SSEPI-C (p 0.05). SNR and CNR in SSEPI-DL were also superior to SSEPI-C (p 0.05). The diagnostic accuracy for detecting deep myometrial invasion showed no significant difference among SSEPI-C, SSEPI-DL and MUSE (p > 0.05). CONCLUSION: DLR improves the image quality of DWI in endometrial cancer, demonstrating image quality equivalent to that of SSEPI-DL and MUSE. SSEPI-DL can be an alternative to MUSE in female pelvic MRI, with the benefit of significantly shortened scan time.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Endometrial NeoplasmsEcho-Planar ImagingDiffusion Magnetic Resonance ImagingDeep LearningImage Interpretation, Computer-AssistedHumansFemaleRetrospective StudiesMiddle AgedAgedAdultAged, 80 and overSignal-To-Noise Ratio

Stichwörter der Autor:innen

Deep learningDiffusion magnetic resonance imagingEndometrial neoplasmsImage reconstructionMagnetic resonance imaging

Autor:innen und Institutionen

  • Department of Radiology, and Biomedical Research Institute, Pusan National University Hospital, Pusan National University School of Medicine, Busan, Republic of Korea.
  • Department of Radiology, and Biomedical Research Institute, Pusan National University Hospital, Pusan National University School of Medicine, Busan, Republic of Korea. leenk77@hanmail.net.
  • Department of Obstetrics and Gynecology, and Biomedical Research Institute, Pusan National University Hospital, Pusan National University School of Medicine, Busan, Republic of Korea.
  • Department of Radiology, Pusan National University Yangsan Hospital, Pusan National University School of Medicine, Yangsan, Republic of Korea.

Förderung

  • clinical research grant from Pusan National University Hospital in 2024

Zitieren

APA

Heo, T., Lee, N. K., Kim, S., Hong, S. B., Suh, D. S., Kim, J. Y., Lee, J. W., & Kim, T. U. (2025). Deep learning reconstruction of diffusion-weighted imaging with single-shot echo-planar imaging in endometrial cancer: a comparison with multi-shot echo-planar imaging. Abdominal Radiology. https://doi.org/10.1007/s00261-025-04955-3

Vancouver

Heo T, Lee NK, Kim S, Hong SB, Suh DS, Kim JY, et al. Deep learning reconstruction of diffusion-weighted imaging with single-shot echo-planar imaging in endometrial cancer: a comparison with multi-shot echo-planar imaging. Abdominal Radiology. 2025. doi:10.1007/s00261-025-04955-3

BibTeX
@article{Heo2025,
  author = {Heo, Taewoo and Lee, Nam Kyung and Kim, Suk and Hong, Seung Baek and Suh, Dong Soo and Kim, Jin You and Lee, Ji Won and Kim, Tae Un},
  title = {Deep learning reconstruction of diffusion-weighted imaging with single-shot echo-planar imaging in endometrial cancer: a comparison with multi-shot echo-planar imaging},
  journal = {Abdominal Radiology},
  year = {2025},
  doi = {10.1007/s00261-025-04955-3}
}
Kostenlos starten →