Optimizing photon counting CT enterography: determining the optimal virtual monoenergy for bowel imaging
Abdominal Radiology · 12.02.2025 · 50 (9) · 3928-3935
DOI: 10.1007/s00261-025-04832-z ↗Kurz gefasst
Fachartikel in der Zeitschrift Abdominal Radiology, online erschienen am 12.02.2025. Verfasst von Arghavan Sharifi und 2 weiteren Autor:innen. Beteiligte Einrichtung: New York University Langone Medical Center, New York, US. arghavan.sharifi@nyulangone.org. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Radiographic Image Interpretation, Computer-Assisted, Intestines, Intestinal Diseases. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 24 Literaturangaben.
Abstract (Originalsprache)
OBJECTIVE: To determine the optimal virtual monoenergy for viewing the bowel at photon-counting CT enterography using quantitative assessment of mural attenuation, contrast-to-noise ratio, signal-to-noise ratio and noise. METHODS: This study was institutional review board approved and Health Insurance Portability and Accountability Act compliant. Consecutive adults (≥ 18 years) who underwent photon-counting CT enterography from 5/1/2022-5/31/2022 with available Spectral Postprocessing (SPP) images for retrospective virtual monoenergy creation were identified. Nine virtual monoenergetic series (40-120 keV, 10 keV increments) were created. Two region-of-interest measurements were placed in the stomach wall, jejunum wall, ileum wall, and each psoas muscle by two radiologists on 0.6 mm images in PACS. Region-of-interests were copied to other virtual monoenergies to ensure identical placement and size. Attenuation (HU) and noise (HU standard deviation) were recorded from each region-of-interest. Signal-to-noise ratio and contrast-to-noise ratio were computed for stomach, jejunum, ileum, and all bowel combined. Pairwise comparisons for attenuation, noise, signal-to-noise ratio and contrast-to-noise ratio for each virtual monoenergy were performed with ANOVA. A p .05). Signal-to-noise ratio was similar from 40 to 70 keV (all p >.05) for all bowel regions. Contrast-to-noise ratio decreased with increasing keV. Contrast-to-noise ratio was similar for all bowel at 40 keV and 50 keV (p =.06), for stomach from 40 to 70 keV (all p >.05), for jejunum from 40 to 50 keV (p =.21), and for ileum from 40 to 60 keV (all p >.05). CONCLUSION: 50 keV virtual monoenergetic images from photon-counting CT enterography optimizes contrast-to-noise ratio while mitigating noise and should routinely be utilized for bowel assessment at photon-counting CT enterography. As most photon-counting CT users primarily interpret virtual monoenergetic images in clinical practice, knowledge of the optimal virtual monoenergy can inform protocol development.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- New York University Langone Medical Center, New York, US. arghavan.sharifi@nyulangone.org.
- Siemens Healthineers (United States), Malvern, US.
- New York University Langone Medical Center, New York, US. bari.dane@nyulangone.org.
Zitieren
APA
Sharifi, A., O'Donnell, T., & Dane, B. (2025). Optimizing photon counting CT enterography: determining the optimal virtual monoenergy for bowel imaging. Abdominal Radiology, 50(9), 3928-3935. https://doi.org/10.1007/s00261-025-04832-z
Vancouver
Sharifi A, O'Donnell T, Dane B. Optimizing photon counting CT enterography: determining the optimal virtual monoenergy for bowel imaging. Abdominal Radiology. 2025;50(9):3928-3935. doi:10.1007/s00261-025-04832-z
BibTeX
@article{Sharifi2025,
author = {Sharifi, Arghavan and O'Donnell, Thomas and Dane, Bari},
title = {Optimizing photon counting CT enterography: determining the optimal virtual monoenergy for bowel imaging},
journal = {Abdominal Radiology},
year = {2025},
volume = {50},
number = {9},
pages = {3928--3935},
doi = {10.1007/s00261-025-04832-z}
}
EUVIMED