EUVIMEDEUVIMED entdecken
Vergleichsstudie

68Ga-DOTA-FAPI-04 and 18F-FDG PET/CT: a head-to-head comparison for peritoneal carcinomatosis diagnostic accuracy

Xiaolin Chen, Xiao Pang, Yan Zhao, Yunuan Liu, Fenglian Jing, Huiqing Yuan, Xiaoshan Chen, Tianyue Li, Yingchen Wang, Yali Liu, Jingya Han, Jingmian Zhang und 3 weitere

Abdominal Radiology · 2025

DOI: 10.1007/s00261-024-04653-6 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Abdominal Radiology, 2025. Verfasst von Xiaolin Chen und 14 weiteren Autor:innen. Beteiligte Einrichtung: Department of Nuclear Medicine, The Fourth Hospital of Hebei Medical University, 12 Jiankang Road, Shijiazhuang, 050011, Hebei, China. Hauptthemen laut MEDLINE: Positron Emission Tomography Computed Tomography, Peritoneal Neoplasms, Fluorodeoxyglucose F18, Radiopharmaceuticals. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 31 Literaturangaben. Gefördert von: Hebei Provincial Health Committee, Hebei Provincial Medical Applicable Technology Tracking Project, Hebei Provincial Department of Science and Technology in China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: The study aimed to compare the diagnostic accuracy of 68Ga-DOTA-FAPI-04 (68Ga-FAPI) and 18F-FDG PET/CT for peritoneal carcinomatosis (PC) in patients with various types of cancer. METHODS: The study enrolled 113 patients with suspected peritoneal malignancy, each of whom underwent 68Ga-FAPI and 18F-FDG PET/CT scans. Lesions in all patients were confirmed through pathology or radiological follow-up. The evaluation and comparison of diagnostic performance, visual scores, maximum standardized uptake value (SUVmax), mean tumor-to-background ratio (TBR), and the peritoneal cancer index (PCI) score were conducted. RESULTS: Compared to 18F-FDG, 68Ga-FAPI PET/CT presented higher sensitivity, negative predictive value, and accuracy for detecting PC on a patient-level (100% vs. 93.2%, 100% vs. 22.22% and 93.81% vs. 86.73%, respectively). Semi-quantitative evaluation revealed that 68Ga-FAPI PET/CT had significantly higher SUVmax and TBR for PC [(6.06 ± 3.04 vs. 4.82 ± 2.75, P = 0.001) and (8.50 ± 5.01 vs. 2.92 ± 1.67, P < 0.001)]. The PCI-FAPI score for PC was higher than the PCI-FDG score (11.28 ± 7.10 vs. 5.69 ± 5.15, P < 0.001). CONCLUSIONS: 68Ga-FAPI has demonstrated superior diagnostic accuracy compared to 18F-FDG PET/CT in detecting PC with various types of cancer, particularly gastric cancer. Additionally, 68Ga-FAPI has shown significantly higher uptake and PCI score in PC compared to 18F-FDG, indicating its potential importance in clinical.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Positron Emission Tomography Computed TomographyPeritoneal NeoplasmsFluorodeoxyglucose F18RadiopharmaceuticalsOrganometallic CompoundsHumansMaleFemaleMiddle AgedAgedSensitivity and SpecificityAdultAged, 80 and overGallium RadioisotopesRetrospective StudiesCoordination ComplexesQuinolines

Stichwörter der Autor:innen

18F-FDG68Ga-FAPIPET/CTPeritoneal cancer indexPeritoneal carcinomatosis

Substanzen

Fluorodeoxyglucose F18RadiopharmaceuticalsOrganometallic Compounds68Ga-FAPIGallium RadioisotopesCoordination ComplexesQuinolines

Autor:innen und Institutionen

  • Department of Nuclear Medicine, The Fourth Hospital of Hebei Medical University, 12 Jiankang Road, Shijiazhuang, 050011, Hebei, China.
  • Department of Oncology, The Fourth Hospital of Hebei Medical University, Shijiazhuang, 050011, Hebei, China.
  • Department of Nuclear Medicine, The Fourth Hospital of Hebei Medical University, 12 Jiankang Road, Shijiazhuang, 050011, Hebei, China. xinmingzhao@hebmu.edu.cn.

Förderung

  • Hebei Provincial Health Committee
  • Hebei Provincial Medical Applicable Technology Tracking Project
  • Hebei Provincial Department of Science and Technology in China

Zitieren

APA

Chen, X., Pang, X., Zhao, Y., Liu, Y., Jing, F., Yuan, H., Chen, X., Li, T., Wang, Y., Liu, Y., Han, J., Zhang, J., Wang, J., Zhang, Z., & Zhao, X. (2025). 68Ga-DOTA-FAPI-04 and 18F-FDG PET/CT: a head-to-head comparison for peritoneal carcinomatosis diagnostic accuracy. Abdominal Radiology. https://doi.org/10.1007/s00261-024-04653-6

Vancouver

Chen X, Pang X, Zhao Y, Liu Y, Jing F, Yuan H, et al. 68Ga-DOTA-FAPI-04 and 18F-FDG PET/CT: a head-to-head comparison for peritoneal carcinomatosis diagnostic accuracy. Abdominal Radiology. 2025. doi:10.1007/s00261-024-04653-6

BibTeX
@article{Chen2025,
  author = {Chen, Xiaolin and Pang, Xiao and Zhao, Yan and Liu, Yunuan and Jing, Fenglian and Yuan, Huiqing and Chen, Xiaoshan and Li, Tianyue and Wang, Yingchen and Liu, Yali and Han, Jingya and Zhang, Jingmian and Wang, Jianfang and Zhang, Zhaoqi and Zhao, Xinming},
  title = {68Ga-DOTA-FAPI-04 and 18F-FDG PET/CT: a head-to-head comparison for peritoneal carcinomatosis diagnostic accuracy},
  journal = {Abdominal Radiology},
  year = {2025},
  doi = {10.1007/s00261-024-04653-6}
}
Kostenlos starten →