EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Iodine density mapping for the diagnosis of acute bowel ischemia using fast kV-switching dual-energy CT

Jack Junchi Xu iD, Peter Sommer Ulriksen, Samir Jawad, Yecatarina Zincuk Rohde, Morten Sejer, Michael Patrick Achiam, Timothy Andrew Resch, Lars Lönn, Kristoffer Lindskov Hansen

Abdominal Radiology · 2023

DOI: 10.1007/s00261-023-04097-4 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Abdominal Radiology, 2023. Verfasst von Jack Junchi Xu und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic Radiology, Copenhagen University Hospital, Rigshospitalet, 2100, Copenhagen, Denmark. jack.junchi.xu@regionh.dk. Hauptthemen laut MEDLINE: Iodine, Mesenteric Ischemia. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Royal Library, Copenhagen University Library.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To evaluate the diagnostic capabilities of a supplementary color ramped iodine density map compared to virtual monoenergetic images (VMIs) at 74 keV in the diagnosis of acute bowel ischemia (ABI).

Methods

Data for this study were prospectively gathered and retrospectively evaluated. Patients referred to the Department of Diagnostic Radiology between October 2020 and August 2022 on the suspicion of ABI and underwent surgery < 12 h following fast kV-switching venous phase abdominal dual-energy CT (DECT) were consecutively included. Images were evaluated by two board-certified radiologists and two radiology residents. First round included only 74 keV VMIs resembling conventional 120 kVp images, and the second round included a supplementary iodine density map. Readers were asked to register presence of ABI as well as their confidence in their diagnosis based on a 5-point Likert scale. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated for each observer with the surgical findings as the gold-standard. McNemar’s and Wilcoxon signed-rank test were used to compare registrations and diagnostic confidence across assessment rounds.

Results

A total of 29 patients resulting in 31 DECT scans were included. Fourteen cases of ischemic/necrotic bowel were reported following surgery. Sensitivity and NPV were decreased with the use of supplementary iodine map images compared to 120 kVp-like images without supplementary iodine map images for three of four observers (round 1 range: 71.4–92.9% and 78.0–94.8%; round 2 range: 57.1–78.6% and 70.1–83.3%, respectively), while specificity and PPV were increased for three of four observers (round 1 range: 64.7–94.1% and 67.4–93.1%; round 2 range: 88.2–94.1% and 73.8–91.1%, respectively). However, no significant difference in ABI diagnosis or diagnostic confidence was found ( p -value range: 0.07–1.00 and 0.23–0.58, respectively).

Conclusion

No significant difference for the diagnosis of ABI was found using supplementary iodine mapping. Our study may suggest a trend of increased specificity and decreased sensitivity, hence, the use of supplementary iodine mapping should be carefully considered.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

IodineMesenteric IschemiaHumansTomography, X-Ray ComputedRetrospective StudiesPredictive Value of TestsIschemiaContrast Media

Stichwörter der Autor:innen

Bowel ischemiaComputed tomographyDual-energy CT

Substanzen

IodineContrast Media

Autor:innen und Institutionen

  • Department of Diagnostic Radiology, Copenhagen University Hospital, Rigshospitalet, 2100, Copenhagen, Denmark. jack.junchi.xu@regionh.dk.
  • Department of Clinical Medicine, University of Copenhagen, 2100, Copenhagen, Denmark. jack.junchi.xu@regionh.dk.
  • Department of Diagnostic Radiology, Copenhagen University Hospital, Rigshospitalet, 2100, Copenhagen, Denmark.
  • Department of Clinical Medicine, University of Copenhagen, 2100, Copenhagen, Denmark.
  • Department of Surgery and Transplantation, Copenhagen University Hospital, Rigshospitalet, 2100, Copenhagen, Denmark.
  • Department of Vascular Surgery, Copenhagen University Hospital, Rigshospitalet, 2100, Copenhagen, Denmark.

ORCID-Profile: Jack Junchi Xu

Förderung

  • Royal Library, Copenhagen University Library

Zitieren

APA

Xu, J. J., Ulriksen, P. S., Jawad, S., Rohde, Y. Z., Sejer, M., Achiam, M. P., Resch, T. A., Lönn, L., & Hansen, K. L. (2023). Iodine density mapping for the diagnosis of acute bowel ischemia using fast kV-switching dual-energy CT. Abdominal Radiology. https://doi.org/10.1007/s00261-023-04097-4

Vancouver

Xu JJ, Ulriksen PS, Jawad S, Rohde YZ, Sejer M, Achiam MP, et al. Iodine density mapping for the diagnosis of acute bowel ischemia using fast kV-switching dual-energy CT. Abdominal Radiology. 2023. doi:10.1007/s00261-023-04097-4

BibTeX
@article{Xu2023,
  author = {Xu, Jack Junchi and Ulriksen, Peter Sommer and Jawad, Samir and Rohde, Yecatarina Zincuk and Sejer, Morten and Achiam, Michael Patrick and Resch, Timothy Andrew and Lönn, Lars and Hansen, Kristoffer Lindskov},
  title = {Iodine density mapping for the diagnosis of acute bowel ischemia using fast kV-switching dual-energy CT},
  journal = {Abdominal Radiology},
  year = {2023},
  doi = {10.1007/s00261-023-04097-4}
}
Kostenlos starten →