A prospective comparison of three ultrasound-based techniques in quantitative diagnosis of hepatic steatosis in NAFLD
Abdominal Radiology · 2023
DOI: 10.1007/s00261-023-04078-7 ↗Kurz gefasst
Fachartikel in der Zeitschrift Abdominal Radiology, 2023. Verfasst von Yuli Zhu und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ultrasound, Zhongshan Hospital, Fudan University, No. 180 Fenglin Road, Shanghai, 200032, China. Hauptthemen laut MEDLINE: Non-alcoholic Fatty Liver Disease, Elasticity Imaging Techniques. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 27 Literaturangaben. Gefördert von: Health Commission Health Sector Clinical Research Special Clinical Project, Science and Technology Commission of Shanghai Municipality, Shanghai Municipal Health Commission.
Abstract (Originalsprache)
PURPOSE: To investigate the correlation between different ultrasound attenuation-based techniques and to compare their diagnostic performances using proton magnetic resonance spectroscopy (1H-MRS) as a reference standard. METHODS: Participants who had clinical suspicion of nonalcoholic fatty liver disease (NAFLD) were prospectively recruited. Each subject had ultrasound with attenuation imaging (ATI) or quantitative ultrasound including tissue attenuation imaging (TAI) and tissue scatter-distribution imaging (TSI), and controlled-attenuation parameter (CAP) and 1H-MRS if available. The technical success rates, intra-observer repeatabilities of attenuation and backscattering coefficient were evaluated. ATI, TAI and CAP were three attenuation-based techniques. Spearman coefficient was used to test correlations among them and 1H-MRS. In addition, the diagnostic performances of these parameters for detecting ≥ 5% or 10% hepatic steatosis were evaluated. RESULTS: 130 participants had ultrasound scanning. Among them, 67 had CAP and 48 had 1H-MRS. The technical success rates were all 100%. The intra-observer repeatabilities of them were also excellent (ICCs > 0.90) and AC-ATI correlated well with AC-TAI (r = 0.752). AC-ATI, AC-TAI showed moderate correlation with CAP, (rATI = 0.623, 95% CI 0.446-0.752, P < 0.001; rTAI = 0.573, 95% CI 0.377-0.720, P < 0.001). For correlation with 1H-MRS, ATI and TAI performed better than CAP(rATI = 0.587; rTAI = 0.712; r CAP = 0.485). The AUCs of ATI, TAI, TSI and CAP for detecting ≥ 5% hepatic steatosis were 0.883, 0.862, 0.870 and 0.868, respectively. The AUC improved to 0.907 when TAI and TSI were combined (P < 0.05). When detecting ≥ 10% hepatic steatosis, the AUCs were 0.855, 0.702, 0.822 and 0.838, respectively. CONCLUSION: Different ultrasound attenuation-based techniques were well correlated and exhibited good diagnostic performances in quantitative diagnosis of hepatic steatosis, however, the threshold values were different. Combinations of multiple parameters may improve the diagnostic performance in detecting hepatic steatosis. TRIAL REGISTRATION: The study has been registered online ( https://www.chictr.org.cn ; unique identifier: ChiCTR2300069459).
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Ultrasound, Zhongshan Hospital, Fudan University, No. 180 Fenglin Road, Shanghai, 200032, China.
- Shanghai Institute of Medical Imaging, Fudan University, Shanghai, 200032, China.
- Institute of Ultrasound in Medicine and Engineering, Fudan University, Shanghai, 200032, China.
- Department of Gastroenterology, Zhongshan Hospital, Fudan University, Shanghai, 200032, China.
- Department of Ultrasound, Zhongshan Hospital, Fudan University, No. 180 Fenglin Road, Shanghai, 200032, China. han.hong@zs-hospital.sh.cn.
- Department of Ultrasound, Zhongshan Hospital, Fudan University, No. 180 Fenglin Road, Shanghai, 200032, China. xu.huixiong@zs-hospital.sh.cn.
ORCID-Profile: Huixiong Xu
Förderung
- Health Commission Health Sector Clinical Research Special Clinical Project
- Science and Technology Commission of Shanghai Municipality
- Shanghai Municipal Health Commission
- Scientific Research and Development Fund of Zhongshan Hospital of Fudan University
- Pilot Medical Construction Project of Fudan University
Zitieren
APA
Zhu, Y., Yin, H., Zhou, D., Zhao, Q., Wang, K., Fan, Y., Chen, K., Han, H., & Xu, H. (2023). A prospective comparison of three ultrasound-based techniques in quantitative diagnosis of hepatic steatosis in NAFLD. Abdominal Radiology. https://doi.org/10.1007/s00261-023-04078-7
Vancouver
Zhu Y, Yin H, Zhou D, Zhao Q, Wang K, Fan Y, et al. A prospective comparison of three ultrasound-based techniques in quantitative diagnosis of hepatic steatosis in NAFLD. Abdominal Radiology. 2023. doi:10.1007/s00261-023-04078-7
BibTeX
@article{Zhu2023,
author = {Zhu, Yuli and Yin, Haohao and Zhou, Da and Zhao, Qiannan and Wang, Kun and Fan, Yunling and Chen, Kailing and Han, Hong and Xu, Huixiong},
title = {A prospective comparison of three ultrasound-based techniques in quantitative diagnosis of hepatic steatosis in NAFLD},
journal = {Abdominal Radiology},
year = {2023},
doi = {10.1007/s00261-023-04078-7}
}
EUVIMED