EUVIMEDEUVIMED entdecken
Crossref

Deep learning-based iodine contrast-augmenting algorithm for low-contrast-dose liver CT to assess hypovascular hepatic metastasis

Taehee Lee iD, Jeong Hee Yoon iD, Jin Young Park iD, Jihyuk Lee iD, Jae Won Choi iD, Chulkyun Ahn iD, Jeong Min Lee iD

Abdominal Radiology · 2023

DOI: 10.1007/s00261-023-04039-0 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Abdominal Radiology, 2023. Verfasst von Taehee Lee und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Seoul National University Hospital, Seoul, Republic of Korea. Hauptthemen laut MEDLINE: Iodine, Deep Learning, Radiography, Dual-Energy Scanned Projection, Liver Neoplasms. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 24 Literaturangaben. Gefördert von: ClariPI.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To investigate the image quality and diagnostic performance of low-contrast-dose liver CT using a deep learning-based iodine contrast-augmenting algorithm (DLICA) for hypovascular hepatic metastases. METHODS: This retrospective study included 128 patients who underwent contrast-enhanced dual-energy CT for hepatic metastasis surveillance between July 2019 and June 2022 using a 30% reduced iodine contrast dose in the portal phase. Three image types were reconstructed: 50-keV virtual monoenergetic images (50-keV VMI); linearly blended images simulating 120-kVp images (120-kVp); and post-processed 120-kVp images using DLICA (DLICA 120-kVp). Three reviewers evaluated lesion conspicuity, image contrast, and subjective image noise. We also measured image noise, contrast-to-noise ratios (CNRs), and signal-to-noise ratios (SNRs). The diagnostic performance for hepatic metastases was evaluated using a jackknife alternative free-response receiver operating characteristic method with the consensus of two independent radiologists as the reference standard. RESULTS: DLICA 120-kVp demonstrated significantly higher CNR of lesions to liver (5.7 ± 3.1 vs. 3.8 ± 2.1 vs. 3.8 ± 2.1) and higher SNR compared with 50-keV VMI and 120-kVp (p < 0.001 for all). DLICA 120-kVp had significantly lower image noise than 50-kVp VMI for all regions (p < 0.001 for all). DLICA 120-kVp also exhibited superior lesion conspicuity (4.0 [3.3-4.3] vs. 3.7 [3.0-4.0] vs. 3.7 [3.0-4.0]), higher image contrast, and lower subjective image noise compared with 50-keV VMI and 120-kVp (p < 0.001 for all). Although there was no significant difference in the figure of merit for lesion diagnosis among the three methods (p = 0.11), DLICA 120-kVp had a significantly higher figure of merit for lesions with a diameter < 20 mm than 50-keV VMI (0.677 vs. 0.648, p = 0.007). On a per-lesion basis, DLICA 120-kVp also demonstrated higher sensitivity than the 50-keV VMI (81.2% vs. 72.9%, p < 0.001). The specificities per lesion were not significantly different among the three algorithms (p = 0.15). CONCLUSION: DLICA at 120-kVp provided superior lesion conspicuity and image quality and similar diagnostic performance for hypovascular hepatic metastases compared with 50-keV VMI.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

IodineDeep LearningRadiography, Dual-Energy Scanned ProjectionLiver NeoplasmsHumansRetrospective StudiesRadiographic Image Interpretation, Computer-AssistedTomography, X-Ray ComputedSignal-To-Noise RatioAlgorithmsIodine Radioisotopes

Stichwörter der Autor:innen

Contrast mediaDeep learningLiverNeoplasm metastasisX-ray computed tomography

Substanzen

IodineIodine-120Iodine Radioisotopes

Autor:innen und Institutionen

  • Department of Radiology, Seoul National University Hospital, Seoul, Republic of Korea.
  • Department of Radiology, Seoul National University College of Medicine, 101, Daehak-ro, Jongno-gu, Seoul, 03080, Republic of Korea.
  • Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Republic of Korea.
  • Department of Radiology, Busan Paik Hospital, Inje University College of Medicine, Busan, Republic of Korea.
  • Department of Radiology, Armed Forces Yangju Hospital, Yangju, Republic of Korea.
  • Department of Transdisciplinary Studies, Program in Biomedical Radiation Sciences, Graduate School of Convergence Science and Technology, Seoul National University, Seoul, Republic of Korea.

ORCID-Profile: Taehee Lee, Jeong Hee Yoon, Jin Young Park, Jihyuk Lee, Jae Won Choi, Chulkyun Ahn, Jeong Min Lee

Förderung

  • ClariPI

Zitieren

APA

Lee, T., Yoon, J. H., Park, J. Y., Lee, J., Choi, J. W., Ahn, C., & Lee, J. M. (2023). Deep learning-based iodine contrast-augmenting algorithm for low-contrast-dose liver CT to assess hypovascular hepatic metastasis. Abdominal Radiology. https://doi.org/10.1007/s00261-023-04039-0

Vancouver

Lee T, Yoon JH, Park JY, Lee J, Choi JW, Ahn C, et al. Deep learning-based iodine contrast-augmenting algorithm for low-contrast-dose liver CT to assess hypovascular hepatic metastasis. Abdominal Radiology. 2023. doi:10.1007/s00261-023-04039-0

BibTeX
@article{Lee2023,
  author = {Lee, Taehee and Yoon, Jeong Hee and Park, Jin Young and Lee, Jihyuk and Choi, Jae Won and Ahn, Chulkyun and Lee, Jeong Min},
  title = {Deep learning-based iodine contrast-augmenting algorithm for low-contrast-dose liver CT to assess hypovascular hepatic metastasis},
  journal = {Abdominal Radiology},
  year = {2023},
  doi = {10.1007/s00261-023-04039-0}
}
Kostenlos starten →