Deep learning-based iodine contrast-augmenting algorithm for low-contrast-dose liver CT to assess hypovascular hepatic metastasis
Abdominal Radiology · 2023
DOI: 10.1007/s00261-023-04039-0 ↗Kurz gefasst
Fachartikel in der Zeitschrift Abdominal Radiology, 2023. Verfasst von Taehee Lee und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Seoul National University Hospital, Seoul, Republic of Korea. Hauptthemen laut MEDLINE: Iodine, Deep Learning, Radiography, Dual-Energy Scanned Projection, Liver Neoplasms. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 24 Literaturangaben. Gefördert von: ClariPI.
Abstract (Originalsprache)
PURPOSE: To investigate the image quality and diagnostic performance of low-contrast-dose liver CT using a deep learning-based iodine contrast-augmenting algorithm (DLICA) for hypovascular hepatic metastases. METHODS: This retrospective study included 128 patients who underwent contrast-enhanced dual-energy CT for hepatic metastasis surveillance between July 2019 and June 2022 using a 30% reduced iodine contrast dose in the portal phase. Three image types were reconstructed: 50-keV virtual monoenergetic images (50-keV VMI); linearly blended images simulating 120-kVp images (120-kVp); and post-processed 120-kVp images using DLICA (DLICA 120-kVp). Three reviewers evaluated lesion conspicuity, image contrast, and subjective image noise. We also measured image noise, contrast-to-noise ratios (CNRs), and signal-to-noise ratios (SNRs). The diagnostic performance for hepatic metastases was evaluated using a jackknife alternative free-response receiver operating characteristic method with the consensus of two independent radiologists as the reference standard. RESULTS: DLICA 120-kVp demonstrated significantly higher CNR of lesions to liver (5.7 ± 3.1 vs. 3.8 ± 2.1 vs. 3.8 ± 2.1) and higher SNR compared with 50-keV VMI and 120-kVp (p < 0.001 for all). DLICA 120-kVp had significantly lower image noise than 50-kVp VMI for all regions (p < 0.001 for all). DLICA 120-kVp also exhibited superior lesion conspicuity (4.0 [3.3-4.3] vs. 3.7 [3.0-4.0] vs. 3.7 [3.0-4.0]), higher image contrast, and lower subjective image noise compared with 50-keV VMI and 120-kVp (p < 0.001 for all). Although there was no significant difference in the figure of merit for lesion diagnosis among the three methods (p = 0.11), DLICA 120-kVp had a significantly higher figure of merit for lesions with a diameter < 20 mm than 50-keV VMI (0.677 vs. 0.648, p = 0.007). On a per-lesion basis, DLICA 120-kVp also demonstrated higher sensitivity than the 50-keV VMI (81.2% vs. 72.9%, p < 0.001). The specificities per lesion were not significantly different among the three algorithms (p = 0.15). CONCLUSION: DLICA at 120-kVp provided superior lesion conspicuity and image quality and similar diagnostic performance for hypovascular hepatic metastases compared with 50-keV VMI.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Radiology, Seoul National University Hospital, Seoul, Republic of Korea.
- Department of Radiology, Seoul National University College of Medicine, 101, Daehak-ro, Jongno-gu, Seoul, 03080, Republic of Korea.
- Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Republic of Korea.
- Department of Radiology, Busan Paik Hospital, Inje University College of Medicine, Busan, Republic of Korea.
- Department of Radiology, Armed Forces Yangju Hospital, Yangju, Republic of Korea.
- Department of Transdisciplinary Studies, Program in Biomedical Radiation Sciences, Graduate School of Convergence Science and Technology, Seoul National University, Seoul, Republic of Korea.
ORCID-Profile: Taehee Lee, Jeong Hee Yoon, Jin Young Park, Jihyuk Lee, Jae Won Choi, Chulkyun Ahn, Jeong Min Lee
Förderung
- ClariPI
Zitieren
APA
Lee, T., Yoon, J. H., Park, J. Y., Lee, J., Choi, J. W., Ahn, C., & Lee, J. M. (2023). Deep learning-based iodine contrast-augmenting algorithm for low-contrast-dose liver CT to assess hypovascular hepatic metastasis. Abdominal Radiology. https://doi.org/10.1007/s00261-023-04039-0
Vancouver
Lee T, Yoon JH, Park JY, Lee J, Choi JW, Ahn C, et al. Deep learning-based iodine contrast-augmenting algorithm for low-contrast-dose liver CT to assess hypovascular hepatic metastasis. Abdominal Radiology. 2023. doi:10.1007/s00261-023-04039-0
BibTeX
@article{Lee2023,
author = {Lee, Taehee and Yoon, Jeong Hee and Park, Jin Young and Lee, Jihyuk and Choi, Jae Won and Ahn, Chulkyun and Lee, Jeong Min},
title = {Deep learning-based iodine contrast-augmenting algorithm for low-contrast-dose liver CT to assess hypovascular hepatic metastasis},
journal = {Abdominal Radiology},
year = {2023},
doi = {10.1007/s00261-023-04039-0}
}
EUVIMED