Predicting successful ultrasound-guided biopsy of liver lesions
Abdominal Radiology · 2023
DOI: 10.1007/s00261-023-04017-6 ↗Kurz gefasst
Fachartikel in der Zeitschrift Abdominal Radiology, 2023. Verfasst von Yarab Al Bulushi und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Beth Israel Deaconess Medical Center, 330 Brookline Avenue, Boston, MA, 02215, USA. Hauptthemen laut MEDLINE: Ultrasonography, Interventional, Image-Guided Biopsy, Liver Neoplasms. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 18 Literaturangaben.
Abstract (Originalsprache)
OBJECTIVES: To determine the factors that affect successful ultrasound-guided biopsy of liver lesions and build a model predicting feasibility of US-guided liver biopsy. METHODS: This is IRB-approved HIPAA-compliant retrospective review of consecutive ultrasound-guided targeted liver biopsies performed or attempted between 1/2018 and 9/2020 at a single tertiary academic institution with a total of 501 patients included. Mann-Whitney and chi-square tests were used to compare continuous and categorical variables, respectively. Logistic regression model was built to predict feasibility of successful ultrasound-guided biopsy. RESULTS: Liver lesion biopsy was successfully performed with US guidance in 429/501 (86%) patients. Lesions not amenable for US biopsy were smaller (median size 1.6 cm vs 3.3 cm, p < 0.0001) and deeper within the liver (median depth 9.0 cm vs 5.8 cm, p < 0.0001). The technical success rate was lowest for lesions in segment II (40/53, 75%), while lesions in segment IVb (87/91, 96%) had highest success rate (p < 0.003). US targeting in patients with 1 or 2 lesions was less feasible than in patients with 3 or more lesions, 126/180 (70%) vs. 303/321 (94%), (p < 0.0001). Model including lesion size, depth, location, and number of lesions predicts feasibility of US-guided biopsy with Area under the ROC curve (AUC) = 0.92. CONCLUSIONS: Linear logistic regression model that includes lesion size, depth and location, and number of lesions is highly successful in predicting feasibility of ultrasound-guided biopsy for liver lesions. Smaller lesions, deeper lesions, and lesions in segment II and VIII in patients with less than 3 lesions were less feasible for ultrasound-guided biopsy of liver lesions.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, Beth Israel Deaconess Medical Center, 330 Brookline Avenue, Boston, MA, 02215, USA.
- Department of Radiology, Beth Israel Deaconess Medical Center, 330 Brookline Avenue, Boston, MA, 02215, USA. obrook@bidmc.harvard.edu.
ORCID-Profile: Olga R Brook
Zitieren
APA
Al Bulushi, Y., Cruz-Romero, C., Kavandi, H., Brook, A., & Brook, O. R. (2023). Predicting successful ultrasound-guided biopsy of liver lesions. Abdominal Radiology. https://doi.org/10.1007/s00261-023-04017-6
Vancouver
Al Bulushi Y, Cruz-Romero C, Kavandi H, Brook A, Brook OR. Predicting successful ultrasound-guided biopsy of liver lesions. Abdominal Radiology. 2023. doi:10.1007/s00261-023-04017-6
BibTeX
@article{AlBulushi2023,
author = {Al Bulushi, Yarab and Cruz-Romero, Cinthia and Kavandi, Hadiseh and Brook, Alexander and Brook, Olga R},
title = {Predicting successful ultrasound-guided biopsy of liver lesions},
journal = {Abdominal Radiology},
year = {2023},
doi = {10.1007/s00261-023-04017-6}
}
EUVIMED