EUVIMEDEUVIMED entdecken
Crossref

Inter-observer agreement and accuracy of LI-RADS v2018 for differentiating tumor in vein from bland thrombus using gadoxetic acid-enhanced magnetic resonance imaging

Shintaro Ichikawa, Claude B Sirlin, Guilherme Moura Cunha, Tanya Wolfson, Kathryn J Fowler, Hiroyuki Morisaka, Kojiro Onohara, Tatsuya Shimizu, Yoshie Omiya, Hiroki Sugiyama, Akihiro Okumura, Hiroshi Onishi

Abdominal Radiology · 2023

DOI: 10.1007/s00261-023-03964-4 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Abdominal Radiology, 2023. Verfasst von Shintaro Ichikawa und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Hamamatsu University School of Medicine, 1-20-1 Handayama, Higashi-ku, Hamamatsu, Shizuoka, 431-3192, Japan. shintaro@hama-m…. Hauptthemen laut MEDLINE: Liver Neoplasms, Carcinoma, Hepatocellular, Thrombosis, Vascular Diseases. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 23 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To assess inter-observer agreement and accuracy of LI-RADS v2018 for differentiating tumor in vein (TIV) from bland thrombus on gadoxetic acid-enhanced magnetic resonance imaging (Gx-MRI). Secondarily, to determine whether a multi-feature model improves accuracy compared to LI-RADS. METHODS: We retrospectively identified consecutive patients at risk for hepatocellular carcinoma with venous occlusion(s) reported on Gx-MRI. Five radiologists independently classified each occlusion as TIV or bland thrombus using the LI-RADS TIV criterion (enhancing soft tissue in vein). They also evaluated imaging features suggestive of TIV or bland thrombus. Intra-class correlation coefficient (ICC) was calculated for individual features. A multi-feature model was developed based on consensus scores of features with > 5% consensus prevalence and > 0.40 ICC. Sensitivity and specificity of the LI-RADS criterion and of the cross-validated multi-feature model were compared. RESULTS: Ninety-eight patients with 103 venous occlusions (58 TIV, 45 bland thrombus) were included. The LI-RADS criterion provided 0.63 ICC and, depending on the reader, 0.62-0.93 sensitivity and 0.87-1.00 specificity. Five other features had > 5% consensus prevalence and > 0.40 ICC, including three LI-RADS suggestive features and two non-LI-RADS features. The optimal multi-feature model incorporated the LI-RADS criterion and one LI-RADS suggestive feature (occluded or obscured vein contiguous with malignant parenchymal mass). After cross-validation, the multi-feature model did not improve sensitivity or specificity compared to the LI-RADS criterion (P = 0.23 and 0.25, respectively). CONCLUSION: Using Gx-MRI, the LI-RADS criterion for TIV provides substantial inter-observer agreement, variable sensitivity, and high specificity for differentiating TIV from bland thrombus. A cross-validated multi-feature model did not improve diagnostic performance.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Liver NeoplasmsCarcinoma, HepatocellularThrombosisVascular DiseasesHumansRetrospective StudiesObserver VariationContrast MediaMagnetic Resonance ImagingSensitivity and SpecificityGadolinium DTPA

Stichwörter der Autor:innen

Bland thrombusGadoxetic acidLI-RADSLiver Imaging Reporting and Data SystemMagnetic resonance imagingTumor in vein

Substanzen

Contrast Mediagadolinium ethoxybenzyl DTPAGadolinium DTPA

Autor:innen und Institutionen

  • Department of Radiology, Hamamatsu University School of Medicine, 1-20-1 Handayama, Higashi-ku, Hamamatsu, Shizuoka, 431-3192, Japan. shintaro@hama-med.ac.jp.
  • Department of Radiology, University of Yamanashi, Chuo, Yamanashi, Japan. shintaro@hama-med.ac.jp.
  • Liver Imaging Group, Department of Radiology, University of California San Diego, San Diego, CA, USA.
  • Department of Radiology, University of Washington, Seattle, WA, USA.
  • Computational and Applied Statistics Laboratory (CASL), San Diego Supercomputer Center at UCSD, San Diego, CA, USA.
  • Department of Radiology, University of Yamanashi, Chuo, Yamanashi, Japan.

Zitieren

APA

Ichikawa, S., Sirlin, C. B., Cunha, G. M., Wolfson, T., Fowler, K. J., Morisaka, H., Onohara, K., Shimizu, T., Omiya, Y., Sugiyama, H., Okumura, A., & Onishi, H. (2023). Inter-observer agreement and accuracy of LI-RADS v2018 for differentiating tumor in vein from bland thrombus using gadoxetic acid-enhanced magnetic resonance imaging. Abdominal Radiology. https://doi.org/10.1007/s00261-023-03964-4

Vancouver

Ichikawa S, Sirlin CB, Cunha GM, Wolfson T, Fowler KJ, Morisaka H, et al. Inter-observer agreement and accuracy of LI-RADS v2018 for differentiating tumor in vein from bland thrombus using gadoxetic acid-enhanced magnetic resonance imaging. Abdominal Radiology. 2023. doi:10.1007/s00261-023-03964-4

BibTeX
@article{Ichikawa2023,
  author = {Ichikawa, Shintaro and Sirlin, Claude B and Cunha, Guilherme Moura and Wolfson, Tanya and Fowler, Kathryn J and Morisaka, Hiroyuki and Onohara, Kojiro and Shimizu, Tatsuya and Omiya, Yoshie and Sugiyama, Hiroki and Okumura, Akihiro and Onishi, Hiroshi},
  title = {Inter-observer agreement and accuracy of LI-RADS v2018 for differentiating tumor in vein from bland thrombus using gadoxetic acid-enhanced magnetic resonance imaging},
  journal = {Abdominal Radiology},
  year = {2023},
  doi = {10.1007/s00261-023-03964-4}
}
Kostenlos starten →