EUVIMEDEUVIMED entdecken
Open Access

Reference values for 4D flow magnetic resonance imaging of the portal venous system

Andrew Huang, Grant S Roberts, Alejandro Roldán-Alzate, Oliver Wieben, Scott B Reeder, Thekla H Oechtering

Abdominal Radiology · 2023

DOI: 10.1007/s00261-023-03892-3 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Abdominal Radiology, 2023. Verfasst von Andrew Huang und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, University of Wisconsin, Madison, WI, USA. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Abdomen. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 45 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIDDK NIH HHS, NIH HHS, National Institutes of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: The purpose of this work was to establish normal reference values for 4D flow MRI-derived flow, velocity, and vessel diameters, and to define characteristic flow patterns in the portal venous system of healthy adult subjects. METHODS: For this retrospective study, we screened all available 4D flow MRI exams of the upper abdomen in healthy adults acquired at our institution between 2012 and 2022 at either 1.5 T or 3.0 T MRI after ≥ 5 h fasting. Flow, velocity, and effective diameter were quantified in the 8 planes in the portal venous system (splenic vein, superior mesenteric vein, main, right, and left portal veins). Vessel delineation was manually adjusted over time. Reference ranges for were defined as the mean ± 2 standard deviations. Three readers noted helical and vortical flow on time-resolved pathline visualizations. Conservation of mass flow analysis was performed for quality assurance. RESULTS: We included 44 healthy subjects (26 female, 18-74 years) in the analysis. We report reference values for mean and peak flow, mean velocity, and vessel diameter in the healthy portal vein using 4D flow MRI. Normal flow patterns in the portal vein included faint helical (66%) or linear flow (34%). Conservation of mass analysis demonstrated a relative error of 1.1 ± 4.6% standard deviation (SD) at the splenomesenteric confluence and - 1.4 ± 4.1% SD at the portal bifurcation. CONCLUSION: We have reported normal hemodynamic values that are necessary baseline data for emerging clinical applications of 4D flow MRI in the portal venous system. Results are consistent with previously published values from smaller cohorts.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingAbdomenAdultHumansFemaleReference ValuesRetrospective StudiesBlood Flow VelocityPortal VeinImaging, Three-Dimensional

Stichwörter der Autor:innen

4D flow MRIPortal hypertensionPortal veinReference values

Autor:innen und Institutionen

  • Department of Radiology, University of Wisconsin, Madison, WI, USA.
  • Section of Vascular Surgery, Department of Surgery, University of Michigan, Ann Arbor, MI, USA.
  • Department of Medical Physics, University of Wisconsin School of Medicine and Public Health, Madison, WI, USA.
  • Department of Mechanical Engineering, University of Wisconsin, Madison, WI, USA.
  • Department of Biomedical Engineering, University of Wisconsin, Madison, WI, USA.
  • Department of Medicine, University of Wisconsin, Madison, WI, USA.

Förderung

  • NIDDK NIH HHS
  • NIH HHS
  • National Institutes of Health
  • Deutsche Forschungsgemeinschaft

Zitieren

APA

Huang, A., Roberts, G. S., Roldán-Alzate, A., Wieben, O., Reeder, S. B., & Oechtering, T. H. (2023). Reference values for 4D flow magnetic resonance imaging of the portal venous system. Abdominal Radiology. https://doi.org/10.1007/s00261-023-03892-3

Vancouver

Huang A, Roberts GS, Roldán-Alzate A, Wieben O, Reeder SB, Oechtering TH. Reference values for 4D flow magnetic resonance imaging of the portal venous system. Abdominal Radiology. 2023. doi:10.1007/s00261-023-03892-3

BibTeX
@article{Huang2023,
  author = {Huang, Andrew and Roberts, Grant S and Roldán-Alzate, Alejandro and Wieben, Oliver and Reeder, Scott B and Oechtering, Thekla H},
  title = {Reference values for 4D flow magnetic resonance imaging of the portal venous system},
  journal = {Abdominal Radiology},
  year = {2023},
  doi = {10.1007/s00261-023-03892-3}
}
Kostenlos starten →