Cholangio-PET/CT with [68Ga]Ga-TEoS-DAZA for bile leak localisation after hepatobiliary surgery
European Journal of Nuclear Medicine and Molecular Imaging · 2026
DOI: 10.1007/s00259-026-08087-8 ↗Kurz gefasst
Fachartikel in der Zeitschrift European Journal of Nuclear Medicine and Molecular Imaging, 2026. Verfasst von Anke Werner und 6 weiteren Autor:innen. Beteiligte Einrichtung: Clinic of Nuclear Medicine, Jena University Hospital, Am Klinikum 1, 07747, Jena, Germany. Hauptthemen laut MEDLINE: Positron Emission Tomography Computed Tomography, Gallium Radioisotopes, Bile, Biliary Tract Surgical Procedures. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universitätsklinikum Jena.
Abstract (Originalsprache)
Purpose
To evaluate the clinical feasibility and potential utility of dynamic [ 68 Ga]Ga-TEoS-DAZA PET/CT for the detection and localisation of bile leaks in patients after hepatobiliary surgery in a small, single-centre feasibility series.
Methods
Ten patients with clinically suspected postoperative bile leakage and prior inconclusive imaging underwent [ 68 Ga]Ga-TEoS-DAZA PET/CT between September 2024 and February 2026. Imaging was performed following intravenous administration of [ 68 Ga]Ga-TEoS-DAZA (mean activity 214 ± 27 MBq). Dynamic PET acquisition was conducted for 60 min. Findings were analysed and classified according to the Nagano system where applicable, and their contribution to subsequent clinical management was assessed. Results [ 68 Ga]Ga-TEoS-DAZA PET/CT enabled localisation of bile leaks in 9 of 10 patients (90%). Leak sites were diverse including central and peripheral locations, as well as complex locations, such as ducts of Luschka and bilioenteric anastomoses. Mean detection time was 28.7 min post injection. PET/CT findings informed subsequent clinical management in all patients, including endoscopic, percutaneous, surgical interventions, or continued drainage management. No adverse effects were observed.
Conclusion
Dynamic [ 68 Ga]Ga-TEoS-DAZA PET/CT was feasible for bile leak localisation in this selected cohort, including complex and peripheral leak sites. Its physiological, antegrade imaging approach provided clinically useful information in patients with inconclusive or unsuccessful conventional imaging. Further prospective comparative studies are warranted to validate these findings and evaluate its diagnostic performance in larger cohorts.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Clinic of Nuclear Medicine, Jena University Hospital, Am Klinikum 1, 07747, Jena, Germany.
- Clinic of General, Visceral and Vascular Surgery, Jena University Hospital, Am Klinikum 1, 07747, Jena, Germany.
- Interdisciplinary Center for Clinical Research (IZKF), Jena University Hospital, Am Klinikum 1, 07747, Jena, Germany.
- Clinic of Nuclear Medicine, Jena University Hospital, Am Klinikum 1, 07747, Jena, Germany. martin.freesmeyer@med.uni-jena.de.
Förderung
- Universitätsklinikum Jena
Zitieren
APA
Werner, A., Drescher, R., Dondorf, F., Rohland, O., Settmacher, U., Greiser, J., & Freesmeyer, M. (2026). Cholangio-PET/CT with [68Ga]Ga-TEoS-DAZA for bile leak localisation after hepatobiliary surgery. European Journal of Nuclear Medicine and Molecular Imaging. https://doi.org/10.1007/s00259-026-08087-8
Vancouver
Werner A, Drescher R, Dondorf F, Rohland O, Settmacher U, Greiser J, et al. Cholangio-PET/CT with [68Ga]Ga-TEoS-DAZA for bile leak localisation after hepatobiliary surgery. European Journal of Nuclear Medicine and Molecular Imaging. 2026. doi:10.1007/s00259-026-08087-8
BibTeX
@article{Werner2026,
author = {Werner, Anke and Drescher, Robert and Dondorf, Felix and Rohland, Oliver and Settmacher, Utz and Greiser, Julia and Freesmeyer, Martin},
title = {Cholangio-PET/CT with [68Ga]Ga-TEoS-DAZA for bile leak localisation after hepatobiliary surgery},
journal = {European Journal of Nuclear Medicine and Molecular Imaging},
year = {2026},
doi = {10.1007/s00259-026-08087-8}
}
EUVIMED