Downstream invasive coronary procedures following PET Versus SPECT myocardial perfusion imaging: a propensity-matched analysis
European Journal of Nuclear Medicine and Molecular Imaging · 2026
DOI: 10.1007/s00259-026-08062-3 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift European Journal of Nuclear Medicine and Molecular Imaging, 2026. Verfasst von Chadi Tabaja und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiovascular Medicine, Cleveland Clinic, Cleveland, OH, USA. Hauptthemen laut MEDLINE: Myocardial Perfusion Imaging, Positron-Emission Tomography, Tomography, Emission-Computed, Single-Photon, Percutaneous Coronary Intervention. Die Arbeit nennt 6 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Methods
We performed a retrospective analysis using the TriNetX Research Network. Adults undergoing PET or SPECT MPI without prior coronary revascularization were identified. The primary endpoint was invasive coronary angiography (ICA) within 90 days, with percutaneous coronary intervention (PCI) as a secondary endpoint. Propensity score matching (1:1) was performed to adjust for baseline differences.
Results
A total of 33,822 propensity-matched patients were included (PET n=16,911; SPECT n=16,911). At 90 days, ICA occurred less frequently after PET compared with SPECT (6.0% vs 6.8%; RR 0.89, 95% CI 0.82-0.97; p=0.005). Conversely, PCI was more frequent following PET (0.9% vs 0.4%; RR 2.00, 95% CI 1.51-2.65; p
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Cardiovascular Medicine, Cleveland Clinic, Cleveland, OH, USA.
- Department of Cardiovascular Medicine, Cleveland Clinic, Cleveland, OH, USA. JABERW@ccf.org.
Zitieren
APA
Tabaja, C., Motairek, I., Abadie, B., Young, L., Menon, V., & Jaber, W. A. (2026). Downstream invasive coronary procedures following PET Versus SPECT myocardial perfusion imaging: a propensity-matched analysis. European Journal of Nuclear Medicine and Molecular Imaging. https://doi.org/10.1007/s00259-026-08062-3
Vancouver
Tabaja C, Motairek I, Abadie B, Young L, Menon V, Jaber WA. Downstream invasive coronary procedures following PET Versus SPECT myocardial perfusion imaging: a propensity-matched analysis. European Journal of Nuclear Medicine and Molecular Imaging. 2026. doi:10.1007/s00259-026-08062-3
BibTeX
@article{Tabaja2026,
author = {Tabaja, Chadi and Motairek, Issam and Abadie, Bryan and Young, Laura and Menon, Venu and Jaber, Wael A},
title = {Downstream invasive coronary procedures following PET Versus SPECT myocardial perfusion imaging: a propensity-matched analysis},
journal = {European Journal of Nuclear Medicine and Molecular Imaging},
year = {2026},
doi = {10.1007/s00259-026-08062-3}
}
EUVIMED