Robotic arm-assisted 18F-FDG PET/CT-guided biopsy in febrile patients with biopsy accessible FDG-avid lesions: a single-centre experience
European Journal of Nuclear Medicine and Molecular Imaging · 2026-07 · 53 (9) · 5597-5604
DOI: 10.1007/s00259-026-07928-w ↗Kurz gefasst
Fachartikel in der Zeitschrift European Journal of Nuclear Medicine and Molecular Imaging, online erschienen am 18.05.2026. Verfasst von Piyush Aggarwal und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Nuclear Medicine, Post Graduate Institute of Medical Education and Research, Chandigarh, 160012, India. Hauptthemen laut MEDLINE: Positron Emission Tomography Computed Tomography, Fluorodeoxyglucose F18, Fever of Unknown Origin, Image-Guided Biopsy. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 26 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: Fever of unknown origin (FUO) is a prolonged fever with unknown etiology after an extensive outpatient or inpatient workup. 18F-Flurodeoxyglucose (FDG) positron emission tomography (PET) with computed tomography (CT) has shown a higher diagnostic yield than CT. This study assesses the diagnostic yield of 18F-FDG PET/CT-guided targeted biopsy in FUO. METHODS: This single-centre retrospective study included FUO patients who underwent 18F-FDG PET/CT-guided biopsy. A distinct focal area of FDG-uptake above the surrounding background within the organ of interest was considered PET-positive and targeted using automated robotic arm-assisted PET/CT-guided biopsy systems. Procedure-related complications were recorded, and histopathological examination was taken as the reference standard. Diagnostic yield and other PET-based parameters were calculated. RESULTS: Data from 165 FUO patients [median age 47 years (IQR, 30-60)] who underwent 18F-FDG PET/CT-guided biopsy between 2017 and June 2025 were analysed. 64 (39%) had undergone a previous procedure with negative or inconclusive results. The most common site of targeted biopsy was the lungs (71/165, 43%). The diagnostic yield of 18F-FDG PET/CT-guided biopsy in FUO patients was 96.4% (159/165), with the most common cause being malignancy (70/165, 42%), followed by infection (58/165, 35%), autoimmune (16/165, 10%) and inflammatory (7/165, 4%) causes. The median SUVmax of the target lesions was 11.8 (IQR, 8.6-16.3; range, 3.3-53.8) with no significant difference among target lesions of different etiologies (p = 0.412). Only six patients (3.6%) had procedure-related complications. CONCLUSION: Robotic arm-assisted 18F-FDG PET/CT-guided biopsy is a safe and accurate procedure in FUO patients having FDG-avid accessible lesions and may help in early diagnosis and management.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Nuclear Medicine, Post Graduate Institute of Medical Education and Research, Chandigarh, 160012, India.
- Department of Nuclear Medicine, Post Graduate Institute of Medical Education and Research, Chandigarh, 160012, India. drrajender2010@gmail.com.
- Department of Internal Medicine, Post Graduate Institute of Medical Education and Research, Chandigarh, India.
- Department of Histopathology, Post Graduate Institute of Medical Education and Research, Chandigarh, India.
- Department of Clinical Hematology and Medical Oncology, Post Graduate Institute of Medical Education and Research, Chandigarh, India.
- Department of Pulmonary Medicine, Post Graduate Institute of Medical Education and Research, Chandigarh, India.
ORCID-Profile: Piyush Aggarwal, Harmandeep Singh, Rajender Kumar
Zitieren
APA
Aggarwal, P., Singh, H., Kumar, R., Mittal, B. R., Pannu, A. K., Bal, A., Prakash, G., Singh, N., Bansal, D., & Sharma, A. (2026). Robotic arm-assisted 18F-FDG PET/CT-guided biopsy in febrile patients with biopsy accessible FDG-avid lesions: a single-centre experience. European Journal of Nuclear Medicine and Molecular Imaging, 53(9), 5597-5604. https://doi.org/10.1007/s00259-026-07928-w
Vancouver
Aggarwal P, Singh H, Kumar R, Mittal BR, Pannu AK, Bal A, et al. Robotic arm-assisted 18F-FDG PET/CT-guided biopsy in febrile patients with biopsy accessible FDG-avid lesions: a single-centre experience. European Journal of Nuclear Medicine and Molecular Imaging. 2026;53(9):5597-5604. doi:10.1007/s00259-026-07928-w
BibTeX
@article{Aggarwal2026,
author = {Aggarwal, Piyush and Singh, Harmandeep and Kumar, Rajender and Mittal, Bhagwant Rai and Pannu, Ashok Kumar and Bal, Amanjit and Prakash, Gaurav and Singh, Navneet and Bansal, Deepak and Sharma, Aman},
title = {Robotic arm-assisted 18F-FDG PET/CT-guided biopsy in febrile patients with biopsy accessible FDG-avid lesions: a single-centre experience},
journal = {European Journal of Nuclear Medicine and Molecular Imaging},
year = {2026},
volume = {53},
number = {9},
pages = {5597--5604},
doi = {10.1007/s00259-026-07928-w}
}
EUVIMED