EUVIMEDEUVIMED entdecken
Crossref

Robotic arm-assisted 18F-FDG PET/CT-guided biopsy in febrile patients with biopsy accessible FDG-avid lesions: a single-centre experience

Piyush Aggarwal iD, Harmandeep Singh iD, Rajender Kumar iD, Bhagwant Rai Mittal, Ashok Kumar Pannu, Amanjit Bal, Gaurav Prakash, Navneet Singh, Deepak Bansal, Aman Sharma

European Journal of Nuclear Medicine and Molecular Imaging · 2026-07 · 53 (9) · 5597-5604

DOI: 10.1007/s00259-026-07928-w ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Journal of Nuclear Medicine and Molecular Imaging, online erschienen am 18.05.2026. Verfasst von Piyush Aggarwal und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Nuclear Medicine, Post Graduate Institute of Medical Education and Research, Chandigarh, 160012, India. Hauptthemen laut MEDLINE: Positron Emission Tomography Computed Tomography, Fluorodeoxyglucose F18, Fever of Unknown Origin, Image-Guided Biopsy. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 26 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: Fever of unknown origin (FUO) is a prolonged fever with unknown etiology after an extensive outpatient or inpatient workup. 18F-Flurodeoxyglucose (FDG) positron emission tomography (PET) with computed tomography (CT) has shown a higher diagnostic yield than CT. This study assesses the diagnostic yield of 18F-FDG PET/CT-guided targeted biopsy in FUO. METHODS: This single-centre retrospective study included FUO patients who underwent 18F-FDG PET/CT-guided biopsy. A distinct focal area of FDG-uptake above the surrounding background within the organ of interest was considered PET-positive and targeted using automated robotic arm-assisted PET/CT-guided biopsy systems. Procedure-related complications were recorded, and histopathological examination was taken as the reference standard. Diagnostic yield and other PET-based parameters were calculated. RESULTS: Data from 165 FUO patients [median age 47 years (IQR, 30-60)] who underwent 18F-FDG PET/CT-guided biopsy between 2017 and June 2025 were analysed. 64 (39%) had undergone a previous procedure with negative or inconclusive results. The most common site of targeted biopsy was the lungs (71/165, 43%). The diagnostic yield of 18F-FDG PET/CT-guided biopsy in FUO patients was 96.4% (159/165), with the most common cause being malignancy (70/165, 42%), followed by infection (58/165, 35%), autoimmune (16/165, 10%) and inflammatory (7/165, 4%) causes. The median SUVmax of the target lesions was 11.8 (IQR, 8.6-16.3; range, 3.3-53.8) with no significant difference among target lesions of different etiologies (p = 0.412). Only six patients (3.6%) had procedure-related complications. CONCLUSION: Robotic arm-assisted 18F-FDG PET/CT-guided biopsy is a safe and accurate procedure in FUO patients having FDG-avid accessible lesions and may help in early diagnosis and management.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Positron Emission Tomography Computed TomographyFluorodeoxyglucose F18Fever of Unknown OriginImage-Guided BiopsyRobotic Surgical ProceduresHumansMiddle AgedFemaleMaleAdultRetrospective StudiesRadiopharmaceuticals

Stichwörter der Autor:innen

BiopsyFeverFluorodeoxyglucose 18FPositron emission tomography computed tomography

Substanzen

Fluorodeoxyglucose F18Radiopharmaceuticals

Autor:innen und Institutionen

  • Department of Nuclear Medicine, Post Graduate Institute of Medical Education and Research, Chandigarh, 160012, India.
  • Department of Nuclear Medicine, Post Graduate Institute of Medical Education and Research, Chandigarh, 160012, India. drrajender2010@gmail.com.
  • Department of Internal Medicine, Post Graduate Institute of Medical Education and Research, Chandigarh, India.
  • Department of Histopathology, Post Graduate Institute of Medical Education and Research, Chandigarh, India.
  • Department of Clinical Hematology and Medical Oncology, Post Graduate Institute of Medical Education and Research, Chandigarh, India.
  • Department of Pulmonary Medicine, Post Graduate Institute of Medical Education and Research, Chandigarh, India.

ORCID-Profile: Piyush Aggarwal, Harmandeep Singh, Rajender Kumar

Zitieren

APA

Aggarwal, P., Singh, H., Kumar, R., Mittal, B. R., Pannu, A. K., Bal, A., Prakash, G., Singh, N., Bansal, D., & Sharma, A. (2026). Robotic arm-assisted 18F-FDG PET/CT-guided biopsy in febrile patients with biopsy accessible FDG-avid lesions: a single-centre experience. European Journal of Nuclear Medicine and Molecular Imaging, 53(9), 5597-5604. https://doi.org/10.1007/s00259-026-07928-w

Vancouver

Aggarwal P, Singh H, Kumar R, Mittal BR, Pannu AK, Bal A, et al. Robotic arm-assisted 18F-FDG PET/CT-guided biopsy in febrile patients with biopsy accessible FDG-avid lesions: a single-centre experience. European Journal of Nuclear Medicine and Molecular Imaging. 2026;53(9):5597-5604. doi:10.1007/s00259-026-07928-w

BibTeX
@article{Aggarwal2026,
  author = {Aggarwal, Piyush and Singh, Harmandeep and Kumar, Rajender and Mittal, Bhagwant Rai and Pannu, Ashok Kumar and Bal, Amanjit and Prakash, Gaurav and Singh, Navneet and Bansal, Deepak and Sharma, Aman},
  title = {Robotic arm-assisted 18F-FDG PET/CT-guided biopsy in febrile patients with biopsy accessible FDG-avid lesions: a single-centre experience},
  journal = {European Journal of Nuclear Medicine and Molecular Imaging},
  year = {2026},
  volume = {53},
  number = {9},
  pages = {5597--5604},
  doi = {10.1007/s00259-026-07928-w}
}
Kostenlos starten →