Time-robust myocardial [68Ga]Ga-FAPI PET biomarker reflects aortic stenosis severity and predicts post-TAVI outcomes
European Journal of Nuclear Medicine and Molecular Imaging · 2026
DOI: 10.1007/s00259-026-07815-4 ↗Kurz gefasst
Fachartikel in der Zeitschrift European Journal of Nuclear Medicine and Molecular Imaging, 2026. Verfasst von Song Xue und 10 weiteren Autor:innen. Beteiligte Einrichtung: Division of Nuclear Medicine, Department of Biomedical Imaging and Image-guided Therapy, Vienna General Hospital, Medical University of Vienna, Vienn…. Hauptthemen laut MEDLINE: Aortic Valve Stenosis, Positron Emission Tomography Computed Tomography, Transcatheter Aortic Valve Replacement, Serine Endopeptidases. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Medical University of Vienna.
Abstract (Originalsprache)
Background
Aortic stenosis (AS) induces myocardial remodeling and fibroblast activation, yet modifiable biomarkers capable of capturing active fibrogenesis and predicting post-transcatheter aortic valve implantation (TAVI) recovery are currently scarce. Fibroblast activation protein (FAP)–targeted PET serves as a noninvasive tool to visualize activated fibroblasts in vivo. We evaluated a time-robust, blood-pool–normalized myocardial [ 68 Ga]Ga-FAPI PET imaging biomarker that reflects AS burden and predicts outcomes after TAVI.
Methods
Nineteen patients with severe symptomatic AS underwent [ 68 Ga]Ga-FAPI-04 PET/CT at 60, 70, and 120 min. Using an in-house semi-automatic pipeline, the left ventricular (LV) myocardium was segmented, and regions of elevated fibroblast activity (EFM) were delineated using a blood-pool–anchored, time-point–specific threshold. We quantified myocardial SUV mean , blood-pool SUV mean , and a normalized myocardium-to-blood index, TBR(EFM), and assessed associations with N-terminal pro-brain natriuretic peptide (NT-proBNP) and left-ventricular ejection fraction (LVEF). One-year outcomes ( n = 11) were assessed using a predefined composite clinical response.
Results
Blood-pool SUV mean declined from 60 to 120 min, whereas myocardial SUV mean decreased less, yielding stable TBR(EFM) across time points (60/70/120 min: 2.2 ± 0.8, 2.1 ± 0.9, 2.3 ± 0.9; ANOVA p = 0.596). By contrast, myocardial SUV mean fell from 3.8 ± 0.7 (60 min) to 2.1 ± 0.9 (120 min; p < 0.001). TBR(EFM) correlated with NT-proBNP at all time-points (60 min r = 0.65, p = 0.007; 120 min r = 0.72, p = 0.003), whereas SUV mean did not (60 min p = 0.576; 120 min p = 0.109). Baseline TBR(EFM) was significantly lower in one-year responders than non-responders (1.7 ± 0.2 vs. 2.9 ± 0.9; p = 0.013), with separation present at each time point ( p < 0.05). Higher baseline TBR(EFM) associated with lower reductions in NT-proBNP at one year ( p < 0.05).
Conclusions
Myocardial [ 68 Ga]Ga-FAPI TBR may provide a time-robust index of active fibroblast signaling that relates to myocardial hemodynamic stress and stratifies one-year clinical response after TAVI. A single 60-minute acquisition with TBR quantification may be sufficient for myocardial [ 68 Ga]Ga-FAPI assessment. These hypothesis-generating findings require validation in larger, multicenter cohorts. Graphical abstract
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Division of Nuclear Medicine, Department of Biomedical Imaging and Image-guided Therapy, Vienna General Hospital, Medical University of Vienna, Vienna, Austria.
- Ludwig Boltzmann Institute for Cardiovascular Research, Center for Biomedical Research and Translational Surgery, Medical University of Vienna, Vienna, Austria.
- Division of Cardiology, Department of Internal Medicine II, Medical University of Vienna, Vienna, Austria.
- Division of Nuclear Medicine, Department of Biomedical Imaging and Image-guided Therapy, Vienna General Hospital, Medical University of Vienna, Vienna, Austria. Xiang.li@meduniwien.ac.at.
- Department of Nuclear Medicine, Beijing Chest Hospital, Capital Medical University, Beijing, China. Xiang.li@meduniwien.ac.at.
ORCID-Profile: Xiang Li
Förderung
- Medical University of Vienna
Zitieren
APA
Xue, S., Ye, Q., Lazarević, A., Hamzaraj, K., Binder, P., Nitsche, C., Kiss, A., Podesser, B. K., Hacker, M., Li, X., & Calabretta, R. (2026). Time-robust myocardial [68Ga]Ga-FAPI PET biomarker reflects aortic stenosis severity and predicts post-TAVI outcomes. European Journal of Nuclear Medicine and Molecular Imaging. https://doi.org/10.1007/s00259-026-07815-4
Vancouver
Xue S, Ye Q, Lazarević A, Hamzaraj K, Binder P, Nitsche C, et al. Time-robust myocardial [68Ga]Ga-FAPI PET biomarker reflects aortic stenosis severity and predicts post-TAVI outcomes. European Journal of Nuclear Medicine and Molecular Imaging. 2026. doi:10.1007/s00259-026-07815-4
BibTeX
@article{Xue2026,
author = {Xue, Song and Ye, Qianling and Lazarević, Aleksa and Hamzaraj, Kevin and Binder, Patrick and Nitsche, Christian and Kiss, Attila and Podesser, Bruno K and Hacker, Marcus and Li, Xiang and Calabretta, Raffaella},
title = {Time-robust myocardial [68Ga]Ga-FAPI PET biomarker reflects aortic stenosis severity and predicts post-TAVI outcomes},
journal = {European Journal of Nuclear Medicine and Molecular Imaging},
year = {2026},
doi = {10.1007/s00259-026-07815-4}
}
EUVIMED