Dynamic frame-by-frame motion correction for 18F-flurpiridaz PET-MPI using convolution neural network
European Journal of Nuclear Medicine and Molecular Imaging · 2026
DOI: 10.1007/s00259-025-07660-x ↗Kurz gefasst
Fachartikel in der Zeitschrift European Journal of Nuclear Medicine and Molecular Imaging, 2026. Verfasst von Meghana Urs und 8 weiteren Autor:innen. Beteiligte Einrichtung: Artificial Intelligence in Medicine Research Center, Departments of Biomedical Sciences, Medicine, and Cardiology, Cedars-Sinai Medical Center, 6500 …. Hauptthemen laut MEDLINE: Positron-Emission Tomography, Pyridazines, Myocardial Perfusion Imaging, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIBIB NIH HHS, NHLBI NIH HHS, Cedars-Sinai Medical Center.
Abstract (Originalsprache)
Purpose
Precise quantification of myocardial blood flow (MBF) and flow reserve (MFR) in 18 F-flurpiridaz PET significantly relies on motion correction (MC). However, the manual frame-by-frame correction leads to significant inter-observer variability, time-consuming, and requires significant experience. We propose a deep learning (DL) framework for automatic MC of 18 F-flurpiridaz PET.
Methods
The method employs a 3D-ResNet based architecture that takes 3D PET volumes and outputs motion vectors. It was validated using 5-fold cross-validation on data from 32-sites of a Phase-III clinical trial (NCT01347710). Manual corrections from two experienced operators served as ground truth, and data augmentation using simulated vectors enhanced training robustness. The study compared the DL approach to both manual and standard non-AI automatic MC methods, assessing agreement and diagnostic accuracy using minimal segmental stress MBF and MFR.
Results
The area under the receiver operating characteristic curves (AUC) for significant CAD were comparable between DL-MC stress MBF, manual-MC stress MBF from Operators (AUC = 0.897, 0.892 and 0.889, respectively; p > 0.05), standard non-AI automatic MC (AUC = 0.877; p > 0.05) and significantly higher than No-MC (AUC = 0.835; p < 0.05). Similar findings were observed with MFR. The 95% confidence limits for agreement with the operator were ± 0.49 (mean difference = 0.00) for MFR and ± 0.24 ml/g/min (mean difference = 0.00) for stress MBF.
Conclusion
DL-MC is significantly faster but diagnostically comparable to manual-MC. The quantitative results obtained with DL-MC for stress MBF and MFR are in excellent agreement with those manually corrected by experienced operators compared to standard non-AI automatic MC in patients undergoing 18 F-flurpiridaz PET-MPI.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Artificial Intelligence in Medicine Research Center, Departments of Biomedical Sciences, Medicine, and Cardiology, Cedars-Sinai Medical Center, 6500 Wilshire Blvd, Los Angeles, CA, 90048, USA.
- Pharmaceutical Diagnostics, GE Healthcare, Buckinghamshire, England, UK.
- Artificial Intelligence in Medicine Research Center, Departments of Biomedical Sciences, Medicine, and Cardiology, Cedars-Sinai Medical Center, 6500 Wilshire Blvd, Los Angeles, CA, 90048, USA. Piotr.Slomka@cshs.org.
ORCID-Profile: Piotr J Slomka
Förderung
- NIBIB NIH HHS
- NHLBI NIH HHS
- Cedars-Sinai Medical Center
Zitieren
APA
Urs, M., Killekar, A., Builoff, V., Lemley, M., Wei, C. C., Ramirez, G., Kavanagh, P., Buckley, C., & Slomka, P. J. (2026). Dynamic frame-by-frame motion correction for 18F-flurpiridaz PET-MPI using convolution neural network. European Journal of Nuclear Medicine and Molecular Imaging. https://doi.org/10.1007/s00259-025-07660-x
Vancouver
Urs M, Killekar A, Builoff V, Lemley M, Wei CC, Ramirez G, et al. Dynamic frame-by-frame motion correction for 18F-flurpiridaz PET-MPI using convolution neural network. European Journal of Nuclear Medicine and Molecular Imaging. 2026. doi:10.1007/s00259-025-07660-x
BibTeX
@article{Urs2026,
author = {Urs, Meghana and Killekar, Aditya and Builoff, Valerie and Lemley, Mark and Wei, Chih-Chun and Ramirez, Giselle and Kavanagh, Paul and Buckley, Christopher and Slomka, Piotr J},
title = {Dynamic frame-by-frame motion correction for 18F-flurpiridaz PET-MPI using convolution neural network},
journal = {European Journal of Nuclear Medicine and Molecular Imaging},
year = {2026},
doi = {10.1007/s00259-025-07660-x}
}
EUVIMED