Comparison of [18F]FAPI-42 and [11C]methionine PET/MRI in defining biological tumor volume with conventional gross tumor volume: consistency and differences
European Journal of Nuclear Medicine and Molecular Imaging · 2026
DOI: 10.1007/s00259-025-07483-w ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift European Journal of Nuclear Medicine and Molecular Imaging, 2026. Verfasst von He Long und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Nuclear Medicine, Daping Hospital, Army Medical University, Chongqing, China. Hauptthemen laut MEDLINE: Methionine, Tumor Burden, Magnetic Resonance Imaging, Positron-Emission Tomography. Die Arbeit nennt 32 Literaturangaben. Gefördert von: Natural Science Foundation of Chongqing, Chongqing Science and Health Joint Medical Research Project-Young and Middle-aged High-level Talent Project, Science and Technology Innovation Ability Enhancement Project of Army Medical University.
Abstract (Originalsprache)
PURPOSE: High-grade gliomas are highly aggressive brain tumors, and precise target volume delineation is crucial for effective treatment. This study aimed to evaluate the concordance and discrepancy between biological tumor volume (BTV) delineated using union of [18F]FAPI-42 and [11C]methionine and conventional gross tumor volume (GTV) in gliomas. METHODS: Nineteen glioma patients were retrospectively enrolled, who underwent [18F]FAPI-42 and [11C]methionine PET/MRI before radiation therapy. The optimal [18F]FAPI-42 threshold for delineation was determined from five predefined thresholds based on volumetric consistency. Target volumes, including BTV based on [18F]FAPI-42 PET (BTV-FAPI), [11C]methionine (BTV-MET), their union (BTV-UNION), GTV on contrast-enhanced T1-weighted MRI (GTV-ce-T1w), clinical target volume (CTV)-UNION, and CTV-ce-T1w were delineated, and geometric comparisons were made between BTV-FAPI and BTV-MET, BTV-UNION and GTV-ce-T1w, and CTV-UNION and CTV-ce-T1w. Dice Similarity Coefficient (DSC), Jaccard similarity coefficient (JSC), and overlap volumes (OV) parameters were calculated for comparison among the different target volumes. RESULTS: The 20% standardized uptake value maximum (SUVmax) threshold was chosen as the optimal value for [18F]FAPI-42 delineation. No significant volume difference was found between BTV-FAPI and BTV-MET (12.64 vs. 9.67 cc; P = 0.562), with low DSC (0.28), JSC (0.17), and OV (0.39). BTV-UNION showed no significant volume difference compared to GTV-ce-T1w (18.41 vs. 8.67 cc; P = 0.073), but had higher OV (0.82) and moderate improvements in DSC (0.50) and JSC (0.33). CTV-UNION was significantly larger than CTV-ce-T1w (198.03 vs. 118.58 cc; P = 0.011), with significant increases in DSC (0.82), JSC (0.70), and OV (0.96). CONCLUSION: The union of [11C]methionine and [18F]FAPI-42 PET for target delineation offers complementary value, enabling the identification of a broader tumor-infiltrated region compared to that delineated by ce-T1w MRI, with potential for reduced glioma recurrence risk.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Nuclear Medicine, Daping Hospital, Army Medical University, Chongqing, China.
- Department of Oncology, Daping Hospital, Army Medical University, Chongqing, China.
- Department of Medical Engineering, Daping Hospital, Army Medical University, Chongqing, China.
- Department of Infectious Diseases, Southwest Hospital, Army Medical University, Chongqing, China.
- Outpatient Department, 32268 Unit, Dali, Yunnan, China.
- Department of Radiology, Daping Hospital, Army Medical University, Chongqing, China. wgzhang01@163.com.
Förderung
- Natural Science Foundation of Chongqing
- Chongqing Science and Health Joint Medical Research Project-Young and Middle-aged High-level Talent Project
- Science and Technology Innovation Ability Enhancement Project of Army Medical University
- AI Medical Research Project of Army Medical Center
- Chongqing Clinical Research Centre of Imaging and Nuclear Medicine
Zitieren
APA
Long, H., He, R., Du, Z., You, J., Li, X., Wang, F., Yao, Y., Cheng, J., Zhang, W., Geng, M., & Chen, X. (2026). Comparison of [18F]FAPI-42 and [11C]methionine PET/MRI in defining biological tumor volume with conventional gross tumor volume: consistency and differences. European Journal of Nuclear Medicine and Molecular Imaging. https://doi.org/10.1007/s00259-025-07483-w
Vancouver
Long H, He R, Du Z, You J, Li X, Wang F, et al. Comparison of [18F]FAPI-42 and [11C]methionine PET/MRI in defining biological tumor volume with conventional gross tumor volume: consistency and differences. European Journal of Nuclear Medicine and Molecular Imaging. 2026. doi:10.1007/s00259-025-07483-w
BibTeX
@article{Long2026,
author = {Long, He and He, Rong and Du, Zhenwei and You, Jianping and Li, Xin and Wang, Fangyang and Yao, Yun and Cheng, Jun and Zhang, Weiguo and Geng, Mingying and Chen, Xiao},
title = {Comparison of [18F]FAPI-42 and [11C]methionine PET/MRI in defining biological tumor volume with conventional gross tumor volume: consistency and differences},
journal = {European Journal of Nuclear Medicine and Molecular Imaging},
year = {2026},
doi = {10.1007/s00259-025-07483-w}
}
EUVIMED