EUVIMEDEUVIMED entdecken
Crossref

Harmonizing Aβ deposition threshold for 18F-florbetaben PET imaging: Addressing discrepancies and calibration between PET/CT and PET/MRI

Huamei Lin, Quanling Jiang, Yunhao Yang, Qi Huang, Ying Zhang, Zhengwei Zhang, Yuhua Zhu, Jiaying Lu, Jing Wang, Min Wang, Jianwei Men, Yufeng Yang und 6 weitere

European Journal of Nuclear Medicine and Molecular Imaging · 2025

DOI: 10.1007/s00259-025-07279-y ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Journal of Nuclear Medicine and Molecular Imaging, 2025. Verfasst von Huamei Lin und 17 weiteren Autor:innen. Beteiligte Einrichtung: Department of Nuclear Medicine/PET Center, Huashan Hospital, Fudan University, Shanghai, China. Hauptthemen laut MEDLINE: Amyloid beta-Peptides, Magnetic Resonance Imaging, Positron Emission Tomography Computed Tomography, Aniline Compounds. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 40 Literaturangaben. Gefördert von: National Nature Science Foundation of China, STI2030-Major Projects.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: Discrepancies between PET/CT and PET/MRI scanners can affect the determination of amyloid beta (Aβ) deposition thresholds in patients with cognitive impairment. This study aimed to identify these differences and propose a calibration method to standardize Aβ quantification across imaging modalities. METHODS: A total of 133 patients with cognitive impairment underwent Aβ PET imaging and were divided into four groups: a head-to-head PET/CT and PET/MRI cohort (group A, n = 6), an independent PET/CT cohort (group B, n = 48), an independent PET/MRI cohort (group C, n = 79), and another independent PET/MRI cohort (group D, n = 10). Standardized uptake value ratios (SUVR) of global cortical target (CTXsuvr) and centiloid (CL) values were compared within group A and between groups B and C. A whole cerebellum (WC)-referenced SUVR method was used to calibrate CL values in group C, with verification in group D. RESULTS: CTXsuvr values were significantly higher in PET/MRI than in PET/CT in both group A (P < 0.05) and group C versus group B (P < 0.001). Aβ-negative/positive cases showed mean ± variance of CTXsuvr as 1.023 ± 0.104/1.479 ± 0.203 in group B and 1.146 ± 0.100/1.743 ± 0.254 in group C, with cutoffs of 1.140 (CL = 20) and 1.401 (CL = 60), respectively. WC-referenced calibration adjusted PET/MRI cutoff to 1.132 (CL = 19) in group C, aligning it with PET/CT thresholds and validated in group D. CONCLUSION: WC-referenced SUVR calibration effectively mitigates differences in Aβ thresholds between PET/CT and PET/MRI, enhancing Aβ quantification standardization in multi-modal imaging.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Amyloid beta-PeptidesMagnetic Resonance ImagingPositron Emission Tomography Computed TomographyAniline CompoundsStilbenesHumansMaleFemaleAgedCalibrationMiddle AgedCognitive DysfunctionAged, 80 and over

Stichwörter der Autor:innen

18F-florbetabenCentiloidCutoffPET/CTPET/MRI

Substanzen

Amyloid beta-Peptides4-(N-methylamino)-4'-(2-(2-(2-fluoroethoxy)ethoxy)ethoxy)stilbeneAniline CompoundsStilbenes

Autor:innen und Institutionen

  • Department of Nuclear Medicine/PET Center, Huashan Hospital, Fudan University, Shanghai, China.
  • Institute of Biomedical Engineering, School of Medicine, Shanghai University, Shanghai, China.
  • Institute of Biomedical Engineering, School of Life Sciences, Shanghai University, Shanghai, 200444, China.
  • Beijing Sinotau International Pharmaceutical Technology Co., Ltd, Beijing, China.
  • Department of Nuclear Medicine/PET Center, Huashan Hospital, Fudan University, Shanghai, China. lovejingjie@126.com.
  • Department of Radiology and Nuclear Medicine, Xuanwu Hospital, Capital Medical University, Beijing, China. imaginglu@hotmail.com.

ORCID-Profile: Jiehui Jiang

Förderung

  • National Nature Science Foundation of China
  • STI2030-Major Projects

Zitieren

APA

Lin, H., Jiang, Q., Yang, Y., Huang, Q., Zhang, Y., Zhang, Z., Zhu, Y., Lu, J., Wang, J., Wang, M., Men, J., Yang, Y., Zhang, H., Guan, Y., Ge, J., Lu, J., Jiang, J., & Zuo, C. (2025). Harmonizing Aβ deposition threshold for 18F-florbetaben PET imaging: Addressing discrepancies and calibration between PET/CT and PET/MRI. European Journal of Nuclear Medicine and Molecular Imaging. https://doi.org/10.1007/s00259-025-07279-y

Vancouver

Lin H, Jiang Q, Yang Y, Huang Q, Zhang Y, Zhang Z, et al. Harmonizing Aβ deposition threshold for 18F-florbetaben PET imaging: Addressing discrepancies and calibration between PET/CT and PET/MRI. European Journal of Nuclear Medicine and Molecular Imaging. 2025. doi:10.1007/s00259-025-07279-y

BibTeX
@article{Lin2025,
  author = {Lin, Huamei and Jiang, Quanling and Yang, Yunhao and Huang, Qi and Zhang, Ying and Zhang, Zhengwei and Zhu, Yuhua and Lu, Jiaying and Wang, Jing and Wang, Min and Men, Jianwei and Yang, Yufeng and Zhang, Huiwei and Guan, Yihui and Ge, Jingjie and Lu, Jie and Jiang, Jiehui and Zuo, Chuantao},
  title = {Harmonizing Aβ deposition threshold for 18F-florbetaben PET imaging: Addressing discrepancies and calibration between PET/CT and PET/MRI},
  journal = {European Journal of Nuclear Medicine and Molecular Imaging},
  year = {2025},
  doi = {10.1007/s00259-025-07279-y}
}
Kostenlos starten →