Myocardial blood flow reference values for 13N-ammonia PET myocardial perfusion imaging in patients without flow-limiting coronary artery disease
European Journal of Nuclear Medicine and Molecular Imaging · 2025
DOI: 10.1007/s00259-025-07196-0 ↗Kurz gefasst
Fachartikel in der Zeitschrift European Journal of Nuclear Medicine and Molecular Imaging, 2025. Verfasst von Rita Pingree und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Nuclear Medicine, Cardiac Imaging, University Hospital and University of Zurich, Zurich, Switzerland. Hauptthemen laut MEDLINE: Ammonia, Myocardial Perfusion Imaging, Nitrogen Radioisotopes, Coronary Artery Disease. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of Zurich.
Abstract (Originalsprache)
Purpose
To determine the most important patient factors influencing quantitative MBF and to report the lower (LRL) and upper (URL) reference limits for 13N-ammonia positron emission tomography (PET) myocardial perfusion imaging (MPI).
Methods
Patients who underwent 13N-ammonia PET-MPI were screened, and those with evidence of myocardial ischemia or scar, known cardiomyopathy, impaired left ventricular function, non-response to vasodilators, and those who underwent a stress-rest protocol were excluded. Multiple linear regression analyses were performed to identify independent predictors of rest MBF (rMBF), stress MBF (sMBF), and myocardial flow reserve (MFR), and predictor importance was calculated. Finally, median, LRL, and URL for rMBF, sMBF, and MFR were calculated based on the presence of predictors.
Results
Among 784 patients with a median coronary artery calcium score (CACS) of 69, median rMBF was 0.75mL∙min − 1 ∙g − 1 (LRL = 0.49 mL∙min − 1 ∙g − 1 ; URL = 1.33 mL∙min − 1 ∙g − 1 ), median sMBF was 2.41mL∙min − 1 ∙g − 1 (LRL = 1.42 mL∙min − 1 ∙g − 1 ; URL = 3.73 mL∙min − 1 ∙g − 1 ), and median MFR was 3.09 (LRL = 2.11; URL = 4.65). The body mass index (BMI) was the single most important independent predictor of rMBF, sMBF, and MFR (predictor importance of 72%, 87%, and 41%, respectively; standardized β=-0.434, -0.566 and − 0.174, respectively). Additional predictors were sex and hypertension for rMBF, sex for sMBF, and hypertension and CACS for MFR.
Conclusion
In patients without flow-limiting CAD, MBF is strongly influenced by the patient’s habitus, whereby median and reference limits for sMBF and rMBF decrease with increasing BMI. Consequently, MFR exhibits stable lower reference limits across a wide range of BMI and may be considered the most robust quantitative parameter derived from 13N-ammonia PET-MPI.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Nuclear Medicine, Cardiac Imaging, University Hospital and University of Zurich, Zurich, Switzerland.
- Department of Cardiology, Gødstrup Hospital, Herning, Denmark.
- Department of Nuclear Medicine, Cardiac Imaging, University Hospital and University of Zurich, Zurich, Switzerland. ronny.buechel@usz.ch.
ORCID-Profile: Ronny R Buechel
Förderung
- University of Zurich
Zitieren
APA
Pingree, R., Markendorf, S., Moysidis, D., Ryffel, C., Stuetz, M., Ghenzi, R., Gajic, M., Benz, D. C., Pazhenkottil, A. P., Giannopoulos, A. A., Kaufmann, P. A., Winther, S., & Buechel, R. R. (2025). Myocardial blood flow reference values for 13N-ammonia PET myocardial perfusion imaging in patients without flow-limiting coronary artery disease. European Journal of Nuclear Medicine and Molecular Imaging. https://doi.org/10.1007/s00259-025-07196-0
Vancouver
Pingree R, Markendorf S, Moysidis D, Ryffel C, Stuetz M, Ghenzi R, et al. Myocardial blood flow reference values for 13N-ammonia PET myocardial perfusion imaging in patients without flow-limiting coronary artery disease. European Journal of Nuclear Medicine and Molecular Imaging. 2025. doi:10.1007/s00259-025-07196-0
BibTeX
@article{Pingree2025,
author = {Pingree, Rita and Markendorf, Susanne and Moysidis, Dimitrios and Ryffel, Christoph and Stuetz, Magdalena and Ghenzi, Raffael and Gajic, Marko and Benz, Dominik C and Pazhenkottil, Aju P and Giannopoulos, Andreas A and Kaufmann, Philipp A and Winther, Simon and Buechel, Ronny R},
title = {Myocardial blood flow reference values for 13N-ammonia PET myocardial perfusion imaging in patients without flow-limiting coronary artery disease},
journal = {European Journal of Nuclear Medicine and Molecular Imaging},
year = {2025},
doi = {10.1007/s00259-025-07196-0}
}
EUVIMED