Impact of deep learning denoising on kinetic modelling for low-dose dynamic PET: application to single- and dual-tracer imaging protocols

Florence M Muller iD, Elizabeth J Li iD, Margaret E Daube-Witherspoon iD, Austin R Pantel iD, Corinde E Wiers iD, Jacob G Dubroff iD, Christian Vanhove iD, Stefaan Vandenberghe iD, Joel S Karp iD

European Journal of Nuclear Medicine and Molecular Imaging · 2025

DOI: 10.1007/s00259-025-07182-6 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Journal of Nuclear Medicine and Molecular Imaging, 2025. Verfasst von Florence M Muller und 8 weiteren Autor:innen. Beteiligte Einrichtung: Medical Image and Signal Processing, Faculty of Engineering and Architecture, Ghent University, Ghent, Belgium. florencemarie.muller@ugent.be. Hauptthemen laut MEDLINE: Deep Learning, Positron-Emission Tomography, Signal-To-Noise Ratio, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 20-mal zitiert (Crossref) und nennt 55 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Research Foundation Flanders (FWO), Fulbright U.S. Student Program, NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Long-axial field-of-view PET scanners capture multi-organ tracer distribution with high sensitivity, enabling lower dose dynamic protocols and dual-tracer imaging for comprehensive disease characterization. However, reducing dose may compromise data quality and time-activity curve (TAC) fitting, leading to higher bias in kinetic parameters. Parametric imaging poses further challenges due to noise amplification in voxel-based modelling. We explore the potential of deep learning denoising (DL-DN) to improve quantification for low-dose dynamic PET.

Methods

Using 16 [ 18 F]FDG PET studies from the PennPET Explorer, we trained a DL framework on 10-min images from late-phase uptake (static data) that were sub-sampled from 1/2 to 1/300 of the counts. This model was used to denoise early-to-late dynamic frame images. Its impact on quantification was evaluated using compartmental modelling and voxel-based graphical analysis for parametric imaging for single- and dual-tracer dynamic studies with [ 18 F]FDG and [ 18 F]FGln at original (injected) and reduced (sub-sampled) doses. Quantification differences were evaluated for the area under the curve of TACs, K i for [ 18 F]FDG and V T for [ 18 F]FGln, and parametric images.

Results

DL-DN consistently improved image quality across all dynamic frames, systematically enhancing TAC consistency and reducing tissue-dependent bias and variability in K i and V T down to 40 MBq doses. DL-DN preserved tumor heterogeneity in Logan V T images and delineation of high-flux regions in Patlak K i maps. In a /[ 18 F]FDG dual-tracer study, bias trends aligned with single-tracer results but showed reduced accuracy for [¹⁸F]FGln in breast lesions at very low doses (4 MBq).

Conclusion

This study demonstrates that applying DL-DN trained on static [ 18 F]FDG PET images to dynamic [ 18 F]FDG and [ 18 F]FGln PET can permit significantly reduced doses, preserving accurate FDG K i and FGln V T measurements, and enhancing parametric image quality. DL-DN shows promise for improving dynamic PET quantification at reduced doses, including novel dual-tracer studies.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Deep LearningPositron-Emission TomographySignal-To-Noise RatioImage Processing, Computer-AssistedRadiation DosageHumansKineticsFluorodeoxyglucose F18FemaleRadiopharmaceuticalsRadioactive Tracers

Stichwörter der Autor:innen

Deep learning denoisingDual-tracer protocolsDynamic LAFOV PETLow-dose imaging

Substanzen

Fluorodeoxyglucose F18RadiopharmaceuticalsRadioactive Tracers

Autor:innen und Institutionen

  • Medical Image and Signal Processing, Faculty of Engineering and Architecture, Ghent University, Ghent, Belgium. florencemarie.muller@ugent.be.
  • Physics and Instrumentation, Department of Radiology, University of Pennsylvania, Philadelphia, PA, US. florencemarie.muller@ugent.be.
  • Physics and Instrumentation, Department of Radiology, University of Pennsylvania, Philadelphia, PA, US.
  • Division of Nuclear Medicine Imaging and Therapy, Department of Radiology, University of Pennsylvania, Philadelphia, PA, US.
  • Center for Studies of Addiction, Department of Psychiatry, University of Pennsylvania, Philadelphia, PA, US.
  • Medical Image and Signal Processing, Faculty of Engineering and Architecture, Ghent University, Ghent, Belgium.

ORCID-Profile: Florence M Muller, Elizabeth J Li, Margaret E Daube-Witherspoon, Austin R Pantel, Corinde E Wiers, Jacob G Dubroff, Christian Vanhove, Stefaan Vandenberghe, Joel S Karp

Förderung

  • Research Foundation Flanders (FWO)
  • Fulbright U.S. Student Program
  • NIH HHS
  • Belgian American Educational Foundation
  • NCI NIH HHS
  • UPenn's Institute for Translational Medicine and Therapeutics
  • National Institutes of Health
  • UPenn’s Institute for Translational Medicine and Therapeutics

Zitieren

APA

Muller, F. M., Li, E. J., Daube-Witherspoon, M. E., Pantel, A. R., Wiers, C. E., Dubroff, J. G., Vanhove, C., Vandenberghe, S., & Karp, J. S. (2025). Impact of deep learning denoising on kinetic modelling for low-dose dynamic PET: application to single- and dual-tracer imaging protocols. European Journal of Nuclear Medicine and Molecular Imaging. https://doi.org/10.1007/s00259-025-07182-6

Vancouver

Muller FM, Li EJ, Daube-Witherspoon ME, Pantel AR, Wiers CE, Dubroff JG, et al. Impact of deep learning denoising on kinetic modelling for low-dose dynamic PET: application to single- and dual-tracer imaging protocols. European Journal of Nuclear Medicine and Molecular Imaging. 2025. doi:10.1007/s00259-025-07182-6

BibTeX
@article{Muller2025,
  author = {Muller, Florence M and Li, Elizabeth J and Daube-Witherspoon, Margaret E and Pantel, Austin R and Wiers, Corinde E and Dubroff, Jacob G and Vanhove, Christian and Vandenberghe, Stefaan and Karp, Joel S},
  title = {Impact of deep learning denoising on kinetic modelling for low-dose dynamic PET: application to single- and dual-tracer imaging protocols},
  journal = {European Journal of Nuclear Medicine and Molecular Imaging},
  year = {2025},
  doi = {10.1007/s00259-025-07182-6}
}
Kostenlos starten →