Direct comparison of the diagnostic accuracy of PET/CT, cranial MRI, ultrasound and temporal artery biopsy in giant cell arteritis
European Journal of Nuclear Medicine and Molecular Imaging · 2025-07 · 52 (9) · 3333-3341
DOI: 10.1007/s00259-025-07166-6 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift European Journal of Nuclear Medicine and Molecular Imaging, online erschienen am 26.02.2025. Verfasst von Lien Moreel und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of General Internal Medicine, UZ Leuven, Herestraat 49, 3000, Leuven, Belgium. Lien.Moreel@uzleuven.be. Hauptthemen laut MEDLINE: Giant Cell Arteritis, Positron Emission Tomography Computed Tomography, Temporal Arteries, Magnetic Resonance Imaging. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 16 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: To evaluate the diagnostic accuracy of PET/CT, cranial MRI, ultrasound and temporal artery biopsy (TAB) in patients with suspected giant cell arteritis (GCA) in a direct comparison. METHODS: Consecutive patients with a suspicion of GCA and at least 2 diagnostic tests ≤ 7 days after initiation of glucocorticoids between June 2021 and June 2024, were included retrospectively. The gold standard for the diagnosis of GCA was the judgment of experienced clinicians after a follow-up of ≥ 6 months. Examinations were compared within subgroups undergoing the same tests. RESULTS: Sixty-one GCA patients and 50 patients with an alternative diagnosis were included. Combined cranial and large vessel PET/CT had the highest sensitivity (89% [95%CI 77-96%]) and specificity (98% [95%CI 88-100%]). Cranial PET/CT and TAB yielded a better sensitivity compared to temporal artery ultrasound (83% [95%CI 64-94%], 77% [95%CI 59-90%] and 55% [95%CI 36-74%], respectively, p = 0.023) without difference in specificity (100% [95%CI 100 - 84%], 95% [95%CI 76-100%] and 81% [95%CI 58-95%], respectively, p = 0.136). Cranial MRI had a sensitivity of 56% (95%CI 21-86%) and specificity of 82% (95%CI 48-98%). Large vessel PET/CT resulted in a better sensitivity compared to axillary artery ultrasound (68% [95%CI 45-86%] vs. 18% [95%CI 5-40%], p = 0.001) without difference in specificity (100% [95% CI 82-100%] vs. 90% [95%CI 67-99%], p = 0.50). CONCLUSION: PET/CT had a better sensitivity than ultrasound and cranial MRI. TAB and cranial PET/CT had a similar diagnostic yield. CLINICAL TRIAL NUMBER: Not applicable.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of General Internal Medicine, UZ Leuven, Herestraat 49, 3000, Leuven, Belgium. Lien.Moreel@uzleuven.be.
- Department of Microbiology, Immunology, and Transplantation, KU Leuven, Leuven, Belgium. Lien.Moreel@uzleuven.be.
- Department of General Internal Medicine, UZ Leuven, Herestraat 49, 3000, Leuven, Belgium.
- Department of Microbiology, Immunology, and Transplantation, KU Leuven, Leuven, Belgium.
- Department of Nuclear Medicine, UZ Leuven, Leuven, Belgium.
- Department of Imaging and Pathology, Nuclear Medicine and Molecular Imaging, KU Leuven, Leuven, Belgium.
ORCID-Profile: Lien Moreel
Zitieren
APA
Moreel, L., Betrains, A., Boeckxstaens, L., Pieters, G., Wuyts, E., Weynand, B., Fourneau, I., Van Laere, K., Demaerel, P., De Langhe, E., Vanderschueren, S., & Blockmans, D. (2025). Direct comparison of the diagnostic accuracy of PET/CT, cranial MRI, ultrasound and temporal artery biopsy in giant cell arteritis. European Journal of Nuclear Medicine and Molecular Imaging, 52(9), 3333-3341. https://doi.org/10.1007/s00259-025-07166-6
Vancouver
Moreel L, Betrains A, Boeckxstaens L, Pieters G, Wuyts E, Weynand B, et al. Direct comparison of the diagnostic accuracy of PET/CT, cranial MRI, ultrasound and temporal artery biopsy in giant cell arteritis. European Journal of Nuclear Medicine and Molecular Imaging. 2025;52(9):3333-3341. doi:10.1007/s00259-025-07166-6
BibTeX
@article{Moreel2025,
author = {Moreel, Lien and Betrains, Albrecht and Boeckxstaens, Lennert and Pieters, Griet and Wuyts, Els and Weynand, Birgit and Fourneau, Inge and Van Laere, Koen and Demaerel, Philippe and De Langhe, Ellen and Vanderschueren, Steven and Blockmans, Daniel},
title = {Direct comparison of the diagnostic accuracy of PET/CT, cranial MRI, ultrasound and temporal artery biopsy in giant cell arteritis},
journal = {European Journal of Nuclear Medicine and Molecular Imaging},
year = {2025},
volume = {52},
number = {9},
pages = {3333--3341},
doi = {10.1007/s00259-025-07166-6}
}
EUVIMED