Evaluation of deep learning-based scatter correction on a long-axial field-of-view PET scanner
European Journal of Nuclear Medicine and Molecular Imaging · 2025-06 · 52 (7) · 2563-2576
DOI: 10.1007/s00259-025-07120-6 ↗Kurz gefasst
Evaluationsstudie in der Zeitschrift European Journal of Nuclear Medicine and Molecular Imaging, online erschienen am 07.02.2025. Verfasst von Baptiste Laurent und 5 weiteren Autor:innen. Beteiligte Einrichtung: LaTIM, Inserm UMR 1101, University of Brest, Brest, France. Hauptthemen laut MEDLINE: Deep Learning, Positron-Emission Tomography, Scattering, Radiation, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 37 Literaturangaben.
Abstract (Originalsprache)
OBJECTIVE: Long-axial field-of-view (LAFOV) positron emission tomography (PET) systems allow higher sensitivity, with an increased number of detected lines of response induced by a larger angle of acceptance. However this extended angle increases the number of multiple scatters and the scatter contribution within oblique planes. As scattering affects both quality and quantification of the reconstructed image, it is crucial to correct this effect with more accurate methods than the state-of-the-art single scatter simulation (SSS) that can reach its limits with such an extended field-of-view (FOV). In this work, which is an extension of our previous assessment of deep learning-based scatter estimation (DLSE) carried out on a conventional PET system, we aim to evaluate the DLSE method performance on LAFOV total-body PET. APPROACH: The proposed DLSE method based on an convolutional neural network (CNN) U-Net architecture uses emission and attenuation sinograms to estimate scatter sinogram. The network was trained from Monte-Carlo (MC) simulations of XCAT phantoms [ 18 F]-FDG PET acquisitions using a Siemens Biograph Vision Quadra scanner model, with multiple morphologies and dose distributions. We firstly evaluated the method performance on simulated data in both sinogram and image domain by comparing it to the MC ground truth and SSS scatter sinograms. We then tested the method on seven [ 18 F]-FDG and [ 18 F]-PSMA clinical datasets, and compare it to SSS estimations. RESULTS: DLSE showed superior accuracy on phantom data, greater robustness to patient size and dose variations compared to SSS, and better lesion contrast recovery. It also yielded promising clinical results, improving lesion contrasts in [ 18 F]-FDG datasets and performing consistently with [ 18 F]-PSMA datasets despite no training with [ 18 F]-PSMA. SIGNIFICANCE: LAFOV PET scatter can be accurately estimated from raw data using the proposed DLSE method.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- LaTIM, Inserm UMR 1101, University of Brest, Brest, France.
- LaTIM, Inserm UMR 1101, University of Brest, Brest, France. alexandre.bousse@univ-brest.fr.
- Department Nuclear Medicine, Bern University Hospital, University of Bern, Bern, Switzerland.
ORCID-Profile: Baptiste Laurent, Alexandre Bousse, Thibaut Merlin, Axel Rominger, Kuangyu Shi, Dimitris Visvikis
Zitieren
APA
Laurent, B., Bousse, A., Merlin, T., Rominger, A., Shi, K., & Visvikis, D. (2025). Evaluation of deep learning-based scatter correction on a long-axial field-of-view PET scanner. European Journal of Nuclear Medicine and Molecular Imaging, 52(7), 2563-2576. https://doi.org/10.1007/s00259-025-07120-6
Vancouver
Laurent B, Bousse A, Merlin T, Rominger A, Shi K, Visvikis D. Evaluation of deep learning-based scatter correction on a long-axial field-of-view PET scanner. European Journal of Nuclear Medicine and Molecular Imaging. 2025;52(7):2563-2576. doi:10.1007/s00259-025-07120-6
BibTeX
@article{Laurent2025,
author = {Laurent, Baptiste and Bousse, Alexandre and Merlin, Thibaut and Rominger, Axel and Shi, Kuangyu and Visvikis, Dimitris},
title = {Evaluation of deep learning-based scatter correction on a long-axial field-of-view PET scanner},
journal = {European Journal of Nuclear Medicine and Molecular Imaging},
year = {2025},
volume = {52},
number = {7},
pages = {2563--2576},
doi = {10.1007/s00259-025-07120-6}
}
EUVIMED