EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Impact of tissue-independent positron range correction on [68Ga]Ga-DOTATOC and [68Ga]Ga-PSMA PET image reconstructions: a patient data study

Prodromos Gavriilidis, Felix M Mottaghy, Michel Koole, Tineke van de Weijer, Cristina Mitea, Jochem A J van der Pol, Thiemo J A van Nijnatten, Floris P Jansen, Roel Wierts iD

European Journal of Nuclear Medicine and Molecular Imaging · 2025-06 · 52 (7) · 2538-2548

DOI: 10.1007/s00259-024-07061-6 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Journal of Nuclear Medicine and Molecular Imaging, online erschienen am 29.01.2025. Verfasst von Prodromos Gavriilidis und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology and Nuclear Medicine, Maastricht University Medical Center, Maastricht, The Netherlands. Hauptthemen laut MEDLINE: Positron Emission Tomography Computed Tomography, Organometallic Compounds, Octreotide, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

The positron range effect can impair PET image quality of Gallium-68 ( 68 Ga). A positron range correction (PRC) can be applied to reduce this effect. In this study, the effect of a tissue-independent PRC for 68 Ga was investigated on patient data.

Methods

PET/CT data (40 patients: [ 68 Ga]Ga-DOTATOC or [ 68 Ga]Ga-PSMA) were reconstructed using Q.Clear reconstruction algorithm. Two reconstructions were performed per patient, Q.Clear with and without PRC. SUV max and contrast-to-noise ratio (CNR) values per lesion were compared between PRC and non-PRC images. Five experienced nuclear medicine physicians reviewed the images and chose the preferred reconstruction based on the image quality, lesion detectability, and diagnostic confidence.

Results

A total of 155 lesions were identified. The PRC resulted in statistically significant increase of the SUV max and CNR for soft tissue lesions (6.4%, p < 0.001; 8.6%, p < 0.001), bone lesions (14.6%, p < 0.001; 12.5%, p < 0.001), and lung lesions (3.6%, p = 0.010; 6.3%, p = 0.001). This effect was most prominent in small lesions (SUV max : 12.0%, p < 0.001, and CNR: 13.0%, p < 0.001). Similar or better image quality, lesion detectability, and diagnostic confidence was achieved in PRC images compared to the non-PRC images as those assessed by the expert readers.

Conclusions

A tissue-independent PRC increased the SUV max and CNR in soft tissue, bone, and lung lesions with a larger effect for the small lesions. Visual assessment demonstrated similar or better image quality, lesion detectability, and diagnostic confidence in PRC images compared to the non-PRC images.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Positron Emission Tomography Computed TomographyOrganometallic CompoundsOctreotideImage Processing, Computer-AssistedEdetic AcidOligopeptidesHumansMaleMiddle AgedAgedFemaleGallium RadioisotopesAdultAged, 80 and overRadiopharmaceuticalsGallium Isotopes

Stichwörter der Autor:innen

Gallium-68Positron Emission TomographyPositron RangePositron Range Correction

Substanzen

Organometallic CompoundsOctreotidegallium 68 PSMA-11Ga(III)-DOTATOCGallium RadioisotopesEdetic AcidOligopeptidesRadiopharmaceuticalsGallium Isotopes

Autor:innen und Institutionen

  • Department of Radiology and Nuclear Medicine, Maastricht University Medical Center, Maastricht, The Netherlands.
  • Research Institute for Oncology and Reproduction (GROW), Maastricht University, Maastricht, The Netherlands.
  • Nuclear Medicine and Molecular Imaging, Department of Imaging & Pathology, KU Leuven, Louvain, Belgium.
  • Department of Nuclear Medicine, RWTH University Hospital, Aachen, Germany.
  • Research Institute of Nutrition Translational Research in Metabolism (NUTRIM), Maastricht University, Maastricht, The Netherlands.
  • Cardiovascular Research Institute Maastricht (CARIM), Maastricht University, Maastricht, The Netherlands.

ORCID-Profile: Roel Wierts

Zitieren

APA

Gavriilidis, P., Mottaghy, F. M., Koole, M., van de Weijer, T., Mitea, C., van der Pol, J. A. J., van Nijnatten, T. J. A., Jansen, F. P., & Wierts, R. (2025). Impact of tissue-independent positron range correction on [68Ga]Ga-DOTATOC and [68Ga]Ga-PSMA PET image reconstructions: a patient data study. European Journal of Nuclear Medicine and Molecular Imaging, 52(7), 2538-2548. https://doi.org/10.1007/s00259-024-07061-6

Vancouver

Gavriilidis P, Mottaghy FM, Koole M, van de Weijer T, Mitea C, van der Pol JAJ, et al. Impact of tissue-independent positron range correction on [68Ga]Ga-DOTATOC and [68Ga]Ga-PSMA PET image reconstructions: a patient data study. European Journal of Nuclear Medicine and Molecular Imaging. 2025;52(7):2538-2548. doi:10.1007/s00259-024-07061-6

BibTeX
@article{Gavriilidis2025,
  author = {Gavriilidis, Prodromos and Mottaghy, Felix M and Koole, Michel and van de Weijer, Tineke and Mitea, Cristina and van der Pol, Jochem A J and van Nijnatten, Thiemo J A and Jansen, Floris P and Wierts, Roel},
  title = {Impact of tissue-independent positron range correction on [68Ga]Ga-DOTATOC and [68Ga]Ga-PSMA PET image reconstructions: a patient data study},
  journal = {European Journal of Nuclear Medicine and Molecular Imaging},
  year = {2025},
  volume = {52},
  number = {7},
  pages = {2538--2548},
  doi = {10.1007/s00259-024-07061-6}
}
Kostenlos starten →