EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Evaluation of long axial field-of-view (LAFOV) PET/CT for post-treatment dosimetry in Yttrium-90 radioembolization of liver tumors: a comparative study with conventional SPECT imaging

Konstantinos G Zeimpekis iD, Hasan Sari iD, Nasir Gözlügöl, Ngwe Rawlings Achangwa, Kuangyu Shi iD, Marc Schindewolf, Ali Afshar-Oromieh iD, Axel Rominger iD, Robert Seifert iD

European Journal of Nuclear Medicine and Molecular Imaging · 2025

DOI: 10.1007/s00259-024-07034-9 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift European Journal of Nuclear Medicine and Molecular Imaging, 2025. Verfasst von Konstantinos G Zeimpekis und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Nuclear Medicine, Inselspital, Bern University Hospital, University of Bern, Freiburgstrasse 18, Bern, 3010, Switzerland. konstantinos.…. Hauptthemen laut MEDLINE: Yttrium Radioisotopes, Liver Neoplasms, Positron Emission Tomography Computed Tomography, Embolization, Therapeutic. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of Bern.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Long axial field-of-view (LAFOV) positron emission tomography/computed tomography (PET/CT) scanners enable high sensitivity and wide anatomical coverage. Therefore, they seem ideal to perform post-selective internal radiation therapy (SIRT) 90 Y scans, which are needed, to confirm that the dose is delivered to the tumors and that healthy organs are spared. However, it is unclear to what extent the use of LAFOV PET is feasible and which dosimetry approaches results in accurate measurements.

Methods

In this retrospective analysis, a total number of 32 patients was included (median age 71, IQR 14), which had hepatocellular carcinoma, cholangiocarcinoma, or liver metastases. All patients underwent SIRT, and the post-therapy scan was acquired on a single photon emission computed tomography/computed tomography (SPECT/CT) and a LAFOV Biograph Quadra PET/CT with a 20-minute acquisition time. Post-treatment dosimetry, regarding the tumor, whole-liver and lung (LMD) absorbed dose was done using an organ-wise (Simplicit90Y) and a voxel-wise approach (HERMIA Dosimetry) which used a semi-Monte Carlo algorithm. The lung shunt fraction (LSF) was also measured using the voxel-wise approach and compared to the planned.

Results

The planning, post-treatment SPECT and PET (SPECT pre , SPECT post , PET post ) median tumor doses based on the organ-wise dosimetry were 276.0 Gy (200.0–330.0 Gy), 232.0 Gy (158.5–303.5 Gy) and 267.5 Gy (182.5–370.8 Gy). In contrast, the median voxel-wise PET post dose was significantly smaller than the planned SPECT pre (152.5 Gy (94.8–223.8 Gy); p < 0.00001). Moreover, the median tumor absorbed dose at 90% (D90) of the tumor volume was significantly higher in SPECT post compared with PET post (123.5 Gy; 81.5–180.0 vs. 30.5 Gy; 11.3-106.3; p < 0.00001). The PET post measured LSF was significantly lower compared to the planned SPECT pre (0.89%; 0.4–1.3% vs. 2.3%; 1.5–3.6%; p < 0.0001). Similarly, the measured PET post median LMD was considerably lower to the planned SPECT pre (1.2 Gy; 0.6–2.3 vs. 2.5 Gy; 1.4–4.7; p < 0.0001).

Conclusion

LAFOV PET enabled the direct measurement of post therapy lung dose and tumor doses that correlated well with the planned treatment doses. However, current voxel-wise-based tumor dosimetry seems to be inaccurate for LAFOV PET. In addition, dose volume histogram-based metrics also significantly underestimate the delivered dose. Therefore, improved dosimetry tools are needed for reliable voxel-wise 90 Y dosimetry to leverage the sensitivity and spatial resolution of LAFOV PET scanners.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Yttrium RadioisotopesLiver NeoplasmsPositron Emission Tomography Computed TomographyEmbolization, TherapeuticHumansMaleFemaleAgedRetrospective StudiesRadiometryMiddle Aged

Stichwörter der Autor:innen

DosimetryLiver radioembolizationQuadraWhole-body PET/CTYttrium-90

Substanzen

Yttrium RadioisotopesYttrium-90

Autor:innen und Institutionen

  • Department of Nuclear Medicine, Inselspital, Bern University Hospital, University of Bern, Freiburgstrasse 18, Bern, 3010, Switzerland. konstantinos.zeimpekis@insel.ch.
  • Department of Nuclear Medicine, Inselspital, Bern University Hospital, University of Bern, Freiburgstrasse 18, Bern, 3010, Switzerland.
  • Advanced Clinical Imaging Technology, Siemens Healthcare AG, Lausanne, Switzerland.
  • Division of Angiology, Swiss Cardiovascular Center, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.

ORCID-Profile: Konstantinos G Zeimpekis, Hasan Sari, Kuangyu Shi, Ali Afshar-Oromieh, Axel Rominger, Robert Seifert

Förderung

  • University of Bern

Zitieren

APA

Zeimpekis, K. G., Sari, H., Gözlügöl, N., Achangwa, N. R., Shi, K., Schindewolf, M., Afshar-Oromieh, A., Rominger, A., & Seifert, R. (2025). Evaluation of long axial field-of-view (LAFOV) PET/CT for post-treatment dosimetry in Yttrium-90 radioembolization of liver tumors: a comparative study with conventional SPECT imaging. European Journal of Nuclear Medicine and Molecular Imaging. https://doi.org/10.1007/s00259-024-07034-9

Vancouver

Zeimpekis KG, Sari H, Gözlügöl N, Achangwa NR, Shi K, Schindewolf M, et al. Evaluation of long axial field-of-view (LAFOV) PET/CT for post-treatment dosimetry in Yttrium-90 radioembolization of liver tumors: a comparative study with conventional SPECT imaging. European Journal of Nuclear Medicine and Molecular Imaging. 2025. doi:10.1007/s00259-024-07034-9

BibTeX
@article{Zeimpekis2025,
  author = {Zeimpekis, Konstantinos G and Sari, Hasan and Gözlügöl, Nasir and Achangwa, Ngwe Rawlings and Shi, Kuangyu and Schindewolf, Marc and Afshar-Oromieh, Ali and Rominger, Axel and Seifert, Robert},
  title = {Evaluation of long axial field-of-view (LAFOV) PET/CT for post-treatment dosimetry in Yttrium-90 radioembolization of liver tumors: a comparative study with conventional SPECT imaging},
  journal = {European Journal of Nuclear Medicine and Molecular Imaging},
  year = {2025},
  doi = {10.1007/s00259-024-07034-9}
}
Kostenlos starten →