Self-supervised neural network for Patlak-based parametric imaging in dynamic [18F]FDG total-body PET
European Journal of Nuclear Medicine and Molecular Imaging · 2025
DOI: 10.1007/s00259-024-07008-x ↗Kurz gefasst
Fachartikel in der Zeitschrift European Journal of Nuclear Medicine and Molecular Imaging, 2025. Verfasst von Wenjian Gu und 9 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Computing, Harbin Institute of Technology, Harbin, China. Hauptthemen laut MEDLINE: Fluorodeoxyglucose F18, Positron-Emission Tomography, Neural Networks, Computer, Whole Body Imaging. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 47 Literaturangaben. Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
PURPOSE: The objective of this study is to generate reliable Ki parametric images from a shortened [18F]FDG total-body PET for clinical applications using a self-supervised neural network algorithm. METHODS: We proposed a self-supervised neural network algorithm with Patlak graphical analysis (SN-Patlak) to generate Ki images from shortened dynamic [18F]FDG PET without 60-min full-dynamic PET-based training. The algorithm deeply integrates neural network architecture with a Patlak method, employing the fitting error of the Patlak plot as the neural network's loss function. As the 0-60 min blood time activity curve (TAC) required by the standard Patlak plot is unobtainable from shortened dynamic PET scans, a population-based "normalized time" (integral-to-instantaneous blood concentration ratio) was used for the linear fitting of Patlak plot of t* to 60 min, and the modified Patlak plot equation was then incorporated into the neural network. Ki images were generated by minimizing the difference between the input layer (measured tissue-to-blood concentration ratios) and the output layer (predicted tissue-to-blood concentration ratios). The effects of t* (20 to 50 min post injection) on the Ki images generated from the SN-Patlak and standard Patlak was evaluated using the normalized mean square error (NMSE), and Pearson's correlation coefficient (Pearson's r). RESULTS: The Ki images generated by the SN-Patlak are robust to the dynamic PET scan duration, and the Ki images generated by the SN-Patlak from just a 10-minute (50-60 min post-injection) dynamic [18F]FDG total-body PET scan are comparable to those generated by the standard Patlak method from 40-min (20-60 min post injection) with NMSE = 0.15 ± 0.03 and Pearson's r = 0.93 ± 0.01. CONCLUSIONS: The SN-Patlak parametric imaging algorithm is robust and reliable for quantification of 10-min dynamic [18F]FDG total-body PET.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Faculty of Computing, Harbin Institute of Technology, Harbin, China.
- United Imaging Healthcare Technology Group Co., Ltd, Shanghai, China.
- School of Biomedical Engineering, ShanghaiTech University, Shanghai, China.
- Institute of Biomedical Manufacturing and Life Quality Engineering, School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai, China.
- Faculty of Computing, Harbin Institute of Technology, Harbin, China. luogongning@hit.edu.cn.
- Faculty of Computing, Harbin Institute of Technology, Harbin, China. wangkq@hit.edu.cn.
ORCID-Profile: Yun Zhou
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Gu, W., Zhu, Z., Liu, Z., Wang, Y., Li, Y., Xu, T., Liu, W., Luo, G., Wang, K., & Zhou, Y. (2025). Self-supervised neural network for Patlak-based parametric imaging in dynamic [18F]FDG total-body PET. European Journal of Nuclear Medicine and Molecular Imaging. https://doi.org/10.1007/s00259-024-07008-x
Vancouver
Gu W, Zhu Z, Liu Z, Wang Y, Li Y, Xu T, et al. Self-supervised neural network for Patlak-based parametric imaging in dynamic [18F]FDG total-body PET. European Journal of Nuclear Medicine and Molecular Imaging. 2025. doi:10.1007/s00259-024-07008-x
BibTeX
@article{Gu2025,
author = {Gu, Wenjian and Zhu, Zhanshi and Liu, Ze and Wang, Yihan and Li, Yanxiao and Xu, Tianyi and Liu, Weiping and Luo, Gongning and Wang, Kuanquan and Zhou, Yun},
title = {Self-supervised neural network for Patlak-based parametric imaging in dynamic [18F]FDG total-body PET},
journal = {European Journal of Nuclear Medicine and Molecular Imaging},
year = {2025},
doi = {10.1007/s00259-024-07008-x}
}
EUVIMED